BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 23411114)

  • 1. Comparison of impact force attenuation by various combinations of hip protector and flooring material using a simplified fall-impact simulation device.
    Li N; Tsushima E; Tsushima H
    J Biomech; 2013 Apr; 46(6):1140-6. PubMed ID: 23411114
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Energy-shunting external hip protector attenuates the peak femoral impact force below the theoretical fracture threshold: an in vitro biomechanical study under falling conditions of the elderly.
    Parkkari J; Kannus P; Heikkilä J; Poutala J; Sievänen H; Vuori I
    J Bone Miner Res; 1995 Oct; 10(10):1437-42. PubMed ID: 8686498
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The force attenuation provided by hip protectors depends on impact velocity, pelvic size, and soft tissue stiffness.
    Laing AC; Robinovitch SN
    J Biomech Eng; 2008 Dec; 130(6):061005. PubMed ID: 19045534
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of hard and soft hip protectors, and the influence of soft tissue.
    van Schoor NM; van der Veen AJ; Schaap LA; Smit TH; Lips P
    Bone; 2006 Aug; 39(2):401-7. PubMed ID: 16546458
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of force attenuation properties of four different hip protectors under simulated falling conditions in the elderly: an in vitro biomechanical study.
    Kannus P; Parkkari J; Poutala J
    Bone; 1999 Aug; 25(2):229-35. PubMed ID: 10456390
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of positioning on the biomechanical performance of soft shell hip protectors.
    Choi WJ; Hoffer JA; Robinovitch SN
    J Biomech; 2010 Mar; 43(5):818-25. PubMed ID: 20018287
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of hip protectors, falling angle and body mass index on pressure distribution over the hip during simulated falls.
    Choi WJ; Hoffer JA; Robinovitch SN
    Clin Biomech (Bristol, Avon); 2010 Jan; 25(1):63-9. PubMed ID: 19766363
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Preventing fall-related vertebral fractures: effect of floor stiffness on peak impact forces during backward falls.
    Sran MM; Robinovitch SN
    Spine (Phila Pa 1976); 2008 Aug; 33(17):1856-62. PubMed ID: 18670338
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of compliant flooring on impact force during falls on the hip.
    Laing AC; Tootoonchi I; Hulme PA; Robinovitch SN
    J Orthop Res; 2006 Jul; 24(7):1405-11. PubMed ID: 16705716
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does the type of flooring affect the risk of hip fracture?
    Simpson AH; Lamb S; Roberts PJ; Gardner TN; Evans JG
    Age Ageing; 2004 May; 33(3):242-6. PubMed ID: 15082428
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of floor surfaces for injury prevention in care settings: impact forces and horizontal pulling force required to move wheeled equipment.
    Keenan BE; Hallas K; Drahota AK; Evans SL
    Osteoporos Int; 2020 Dec; 31(12):2383-2394. PubMed ID: 32647950
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hip protectors: a pilot study of older people in Taiwan.
    Huang HC; Lee CH; Wu SL
    J Clin Nurs; 2006 Apr; 15(4):436-43. PubMed ID: 16553757
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anatomical hip model for the mechanical testing of hip protectors.
    Derler S; Spierings AB; Schmitt KU
    Med Eng Phys; 2005 Jul; 27(6):475-85. PubMed ID: 15990064
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prevention of hip fracture with hip protectors.
    Kannus P; Parkkari J
    Age Ageing; 2006 Sep; 35 Suppl 2():ii51-ii54. PubMed ID: 16926206
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Risk of hip fractures in soft protected, hard protected, and unprotected falls.
    Bentzen H; Bergland A; Forsén L
    Inj Prev; 2008 Oct; 14(5):306-10. PubMed ID: 18836047
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of soft shell hip protectors on pressure distribution to the hip during sideways falls.
    Laing AC; Robinovitch SN
    Osteoporos Int; 2008 Jul; 19(7):1067-75. PubMed ID: 18338098
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Force attenuation properties of various trochanteric padding materials under typical falling conditions of the elderly.
    Parkkari J; Kannus P; Poutala J; Vuori I
    J Bone Miner Res; 1994 Sep; 9(9):1391-6. PubMed ID: 7817822
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Can flooring and underlay materials reduce hip fractures in older people?
    Minns J; Nabhani F; Bamford JS
    Nurs Older People; 2004; 16(5):16-20. PubMed ID: 15303514
    [No Abstract]   [Full Text] [Related]  

  • 19. Low stiffness floors can attenuate fall-related femoral impact forces by up to 50% without substantially impairing balance in older women.
    Laing AC; Robinovitch SN
    Accid Anal Prev; 2009 May; 41(3):642-50. PubMed ID: 19393817
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical study of an anthropometrically designed hip protector for older chinese women.
    Sze PC; Cheung WH; Qin L; Tam KF; Ng WK; Leung KS
    Geriatr Nurs; 2008; 29(1):64-9. PubMed ID: 18267179
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.