These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
210 related articles for article (PubMed ID: 23413131)
1. Effect of proximal femoral bone support on the fixation of a press-fit noncemented total hip replacement femoral component. Sangiorgio SN; Ebramzadeh E; Borkowski SL; Oakes DA; Reid JJ; Bengs BC J Appl Biomater Funct Mater; 2013 Jun; 11(1):e26-34. PubMed ID: 23413131 [TBL] [Abstract][Full Text] [Related]
2. Fixation of non-cemented total hip arthroplasty femoral components in a simulated proximal bone defect model. Sangiorgio SN; Ebramzadeh E; Knutsen AR; Borkowski SL; Kalma JJ; Bengs BC J Arthroplasty; 2013 Oct; 28(9):1618-24. PubMed ID: 23523487 [TBL] [Abstract][Full Text] [Related]
3. Stem geometry changes initial femoral fixation stability of a revised press-fit hip prosthesis: A finite element study. Russell RD; Huo MH; Rodrigues DC; Kosmopoulos V Technol Health Care; 2016 Nov; 24(6):865-872. PubMed ID: 27434281 [TBL] [Abstract][Full Text] [Related]
4. A novel locking screw hip stem to achieve immediate stability in total hip arthroplasty: A biomechanical study. Grechenig S; Gueorguiev B; Berner A; Heiss P; Müller M; Nerlich M; Schmitz P Injury; 2015 Oct; 46 Suppl 4():S83-7. PubMed ID: 26542871 [TBL] [Abstract][Full Text] [Related]
5. The Proximal and Distal Femoral Canal Geometry Influences Cementless Stem Anchorage and Revision Hip and Knee Implant Stability. Heinecke M; Rathje F; Layher F; Matziolis G Orthopedics; 2018 May; 41(3):e369-e375. PubMed ID: 29570762 [TBL] [Abstract][Full Text] [Related]
6. Tapered vs Cylindrical Stem Fixation in a Model of Femoral Bone Deficiency in Revision Total Hip Arthroplasty. Russell RD; Pierce W; Huo MH J Arthroplasty; 2016 Jun; 31(6):1352-1355. PubMed ID: 26795255 [TBL] [Abstract][Full Text] [Related]
7. Initial stability of fully and partially cemented femoral stems. Claes L; Fiedler S; Ohnmacht M; Duda GN Clin Biomech (Bristol, Avon); 2000 Dec; 15(10):750-5. PubMed ID: 11050357 [TBL] [Abstract][Full Text] [Related]
8. Influence of the fixation region of a press-fit hip endoprosthesis on the stress-strain state of the "bone-implant" system. Levadnyi I; Awrejcewicz J; Goethel MF; Loskutov A Comput Biol Med; 2017 May; 84():195-204. PubMed ID: 28390287 [TBL] [Abstract][Full Text] [Related]
9. Stem micromotion after femoral impaction grafting using irradiated allograft bone: a time zero in vitro study. Costi JJ; Edmonds-Wilson RH; Howie DW; Stamenkov R; Field JR; Stanley RM; Hearn TC; Callary SA; McGee MA Clin Biomech (Bristol, Avon); 2013 Aug; 28(7):770-6. PubMed ID: 23896432 [TBL] [Abstract][Full Text] [Related]
10. Cementless revision femoral stems application of press-fit principles and clinical outcomes. Canovas F; Putman S; Dagneaux L; Chadli L; Le Béguec P Int Orthop; 2019 Oct; 43(10):2261-2267. PubMed ID: 30554260 [TBL] [Abstract][Full Text] [Related]
11. A plasma-sprayed titanium proximal coating reduces the risk of periprosthetic femoral fracture in cementless hip arthroplasty. Miles B; Walter WL; Kolos E; Waters T; Appleyard R; Gillies RM; Donohoo S; Ruys AJ Biomed Mater Eng; 2015; 25(3):267-78. PubMed ID: 26407113 [TBL] [Abstract][Full Text] [Related]
12. Revision total hip arthroplasty in patients with extensive proximal femoral bone loss using a fluted tapered modular femoral component. Amanatullah DF; Howard JL; Siman H; Trousdale RT; Mabry TM; Berry DJ Bone Joint J; 2015 Mar; 97-B(3):312-7. PubMed ID: 25737513 [TBL] [Abstract][Full Text] [Related]
13. Can plate osteosynthesis of periprosthethic femoral fractures cause cement mantle failure around a stable hip stem? A biomechanical analysis. Giesinger K; Ebneter L; Day RE; Stoffel KK; Yates PJ; Kuster MS J Arthroplasty; 2014 Jun; 29(6):1308-12. PubMed ID: 24439999 [TBL] [Abstract][Full Text] [Related]
14. A quantitative analysis of bone support comparing cementless tapered and distal fixation total hip replacements. Howard JL; Hui AJ; Bourne RB; McCalden RW; MacDonald SJ; Rorabeck CH J Arthroplasty; 2004 Apr; 19(3):266-73. PubMed ID: 15067636 [TBL] [Abstract][Full Text] [Related]
15. Modified transfemoral approach to revision arthroplasty with uncemented modular revision stems. Fink B; Grossmann A Oper Orthop Traumatol; 2007 Mar; 19(1):32-55. PubMed ID: 17345026 [TBL] [Abstract][Full Text] [Related]
16. Deformation pattern and load transfer of an uncemented femoral stem with modular necks. An experimental study in human cadaver femurs. Enoksen CH; Gjerdet NR; Klaksvik J; Arthursson AJ; Schnell-Husby O; Wik TS Clin Biomech (Bristol, Avon); 2016 Feb; 32():28-33. PubMed ID: 26785385 [TBL] [Abstract][Full Text] [Related]
17. The influence of proximal stem geometry and surface finish on the fixation of a double-tapered cemented femoral stem. Sangiorgio SN; Longjohn DB; Dorr LD; Ebramzadeh E J Biomech; 2011 Jan; 44(1):22-7. PubMed ID: 20828697 [TBL] [Abstract][Full Text] [Related]