These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 23415696)

  • 1. Enzymatic but not compensated Jaffe methods reach the desirable specifications of NKDEP at normal levels of creatinine. Results of the French multicentric evaluation.
    Boutten A; Bargnoux AS; Carlier MC; Delanaye P; Rozet E; Delatour V; Cavalier E; Hanser AM; Froissart M; Cristol JP; Piéroni L;
    Clin Chim Acta; 2013 Apr; 419():132-5. PubMed ID: 23415696
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A multicentric evaluation of IDMS-traceable creatinine enzymatic assays.
    Piéroni L; Delanaye P; Boutten A; Bargnoux AS; Rozet E; Delatour V; Carlier MC; Hanser AM; Cavalier E; Froissart M; Cristol JP;
    Clin Chim Acta; 2011 Nov; 412(23-24):2070-5. PubMed ID: 21803031
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Results of the recalibration of creatinine measurement with the modular Beckman Coulter Jaffe creatinine method.
    Fillée C; Vranken G; Othmane M; Philippe M; Allaeys JM; Courbe A; Ruelle JL; Peeters R
    Clin Chem Lab Med; 2011 Dec; 49(12):1987-99. PubMed ID: 21801031
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Does the ID-MS traceable MDRD equation work and is it suitable for use with compensated Jaffe and enzymatic creatinine assays?
    Vickery S; Stevens PE; Dalton RN; van Lente F; Lamb EJ
    Nephrol Dial Transplant; 2006 Sep; 21(9):2439-45. PubMed ID: 16720592
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reference values for serum creatinine with Jaffe-compensated assay in adult Iranian subjects: Tehran Lipid and Glucose Study.
    Ghasemi A; Azimzadeh I; Zahediasl S; Azizi F
    Arch Iran Med; 2014 Jun; 17(6):394-9. PubMed ID: 24916523
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of a liquid chromatography tandem mass spectrometry assay for serum creatinine and comparison with enzymatic and Jaffe methods.
    Owen LJ; Wear JE; Keevil BG
    Ann Clin Biochem; 2006 Mar; 43(Pt 2):118-23. PubMed ID: 16536913
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison between ADVIA Chemistry systems Enzymatic Creatinine_2 method and ADVIA Chemistry systems Creatinine method (kinetic Jaffe method) for determining creatinine.
    Hermida FJ; Lorenzo MJ; Pérez A; Fernández M; Sagastagoia O; Magadán C
    Scand J Clin Lab Invest; 2014 Oct; 74(7):629-36. PubMed ID: 24988313
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of standardization of creatinine methodology on the assessment of glomerular filtration rate in children.
    Srivastava T; Alon US; Althahabi R; Garg U
    Pediatr Res; 2009 Jan; 65(1):113-6. PubMed ID: 18703997
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Post-standardization of routine creatinine assays: are they suitable for clinical applications.
    Jassam N; Weykamp C; Thomas A; Secchiero S; Sciacovelli L; Plebani M; Thelen M; Cobbaert C; Perich C; Ricós C; Paula FA; Barth JH
    Ann Clin Biochem; 2017 May; 54(3):386-394. PubMed ID: 27496794
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Applicability of common reference intervals for serum creatinine concentrations to the Croatian population.
    Flegar-Mestrić Z; Perkov S; Simonović B; Juretić D
    Clin Chem Lab Med; 2010 Feb; 48(2):231-5. PubMed ID: 19943808
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Limitations of compensated Jaffe creatinine assays in cirrhotic patients.
    Kuster N; Bargnoux AS; Pageaux GP; Cristol JP
    Clin Biochem; 2012 Mar; 45(4-5):320-5. PubMed ID: 22178107
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of reference intervals for serum creatinine, creatinine excretion and creatinine clearance with an enzymatic and a modified Jaffé method.
    Junge W; Wilke B; Halabi A; Klein G
    Clin Chim Acta; 2004 Jun; 344(1-2):137-48. PubMed ID: 15149882
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of Jaffé rate assay and enzymatic method for the measurement of creatinine clearance.
    Horio M; Orita Y
    Nihon Jinzo Gakkai Shi; 1996 Jul; 38(7):296-9. PubMed ID: 8741390
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Specificity characteristics of 7 commercial creatinine measurement procedures by enzymatic and Jaffe method principles.
    Greenberg N; Roberts WL; Bachmann LM; Wright EC; Dalton RN; Zakowski JJ; Miller WG
    Clin Chem; 2012 Feb; 58(2):391-401. PubMed ID: 22166253
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Enzymatic assays for creatinine: time for action.
    Panteghini M
    Scand J Clin Lab Invest Suppl; 2008; 241():84-8. PubMed ID: 18569972
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Susceptibility of glomerular filtration rate estimations to variations in creatinine methodology: a study in older patients.
    Lamb EJ; Wood J; Stowe HJ; O'Riordan SE; Webb MC; Dalton RN
    Ann Clin Biochem; 2005 Jan; 42(Pt 1):11-8. PubMed ID: 15802027
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lower creatinine concentration values and lower inter-laboratory variation among Swedish hospital laboratories in 2014 compared to 1996: results from the Equalis external quality assessment program.
    Helmersson-Karlqvist J; Ridefelt P; Boija EE; Nordin G
    Clin Chem Lab Med; 2019 May; 57(6):838-844. PubMed ID: 30982002
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of a compensated Jaffe creatinine method on the estimation of glomerular filtration rate.
    Chan MH; Ng KF; Szeto CC; Lit LC; Chow KM; Leung CB; Suen MW; Li PK; Lam CW
    Ann Clin Biochem; 2004 Nov; 41(Pt 6):482-4. PubMed ID: 15588439
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Risk Assessment of the Jaffe vs Enzymatic Method for Creatinine Measurement in an Outpatient Population.
    Schmidt RL; Straseski JA; Raphael KL; Adams AH; Lehman CM
    PLoS One; 2015; 10(11):e0143205. PubMed ID: 26599086
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation and comparison of Abbott Jaffe and enzymatic creatinine methods: Could the old method meet the new requirements?
    Küme T; Sağlam B; Ergon C; Sisman AR
    J Clin Lab Anal; 2018 Jan; 32(1):. PubMed ID: 28205269
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.