These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

71 related articles for article (PubMed ID: 2341897)

  • 1. Design and performance of POSICAM 6.5 BGO positron camera.
    Mullani NA; Gould KL; Hartz RK; Hitchens RE; Wong WH; Bristow D; Adler S; Philippe EA; Bendriem B; Sanders M
    J Nucl Med; 1990 May; 31(5):610-6. PubMed ID: 2341897
    [TBL] [Abstract][Full Text] [Related]  

  • 2. PET camera performance design evaluation for BGO and BaF2 scintillators (non-time-of-flight).
    Wong WH
    J Nucl Med; 1988 Mar; 29(3):338-47. PubMed ID: 3258027
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous-slice PENN-PET: a positron tomograph with volume imaging capability.
    Karp JS; Muehllehner G; MankofF DA; Ordonez CE; Ollinger JM; Daube-Witherspoon ME; Haigh AT; Beerbohm DJ
    J Nucl Med; 1990 May; 31(5):617-27. PubMed ID: 2341898
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard.
    Matsumoto K; Kitamura K; Mizuta T; Tanaka K; Yamamoto S; Sakamoto S; Nakamoto Y; Amano M; Murase K; Senda M
    J Nucl Med; 2006 Jan; 47(1):83-90. PubMed ID: 16391191
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Imaging characteristics of a 3-dimensional GSO whole-body PET camera.
    Surti S; Karp JS
    J Nucl Med; 2004 Jun; 45(6):1040-9. PubMed ID: 15181139
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A rotating PET scanner using BGO block detectors: design, performance and applications.
    Townsend DW; Wensveen M; Byars LG; Geissbuhler A; Tochon-Danguy HJ; Christin A; Defrise M; Bailey DL; Grootoonk S; Donath A
    J Nucl Med; 1993 Aug; 34(8):1367-76. PubMed ID: 8326401
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance evaluation of a very high resolution small animal PET imager using silicon scatter detectors.
    Park SJ; Rogers WL; Huh S; Kagan H; Honscheid K; Burdette D; Chesi E; Lacasta C; Llosa G; Mikuz M; Studen A; Weilhammer P; Clinthorne NH
    Phys Med Biol; 2007 May; 52(10):2807-26. PubMed ID: 17473353
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design and use of PET tomographs: the effect of slice spacing.
    Miller TR; Wallis JW; Grothe RA
    J Nucl Med; 1990 Oct; 31(10):1732-9. PubMed ID: 2213200
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The PETRRA positron camera: design, characterization and results of a physical evaluation.
    Divoli A; Flower MA; Erlandsson K; Reader AJ; Evans N; Meriaux S; Ott RJ; Stephenson R; Bateman JE; Duxbury DM; Spill EJ
    Phys Med Biol; 2005 Sep; 50(17):3971-88. PubMed ID: 16177524
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Some physical characteristics of a time-of-flight positron tomography (CEA-LETI-TTV03) obtained with the EEC emission phantom.
    Trebossen R; Mazoyer BM
    Med Prog Technol; 1991; 17(3-4):165-71. PubMed ID: 1839846
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance characteristics of Positologica III: a whole-body positron emission tomograph.
    Senda M; Tamaki N; Yonekura Y; Tanada S; Murata K; Hayashi N; Fujita T; Saji H; Konishi J; Torizuka K
    J Comput Assist Tomogr; 1985; 9(5):940-6. PubMed ID: 3875640
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance evaluation of the positron scanner ECAT EXACT.
    Wienhard K; Eriksson L; Grootoonk S; Casey M; Pietrzyk U; Heiss WD
    J Comput Assist Tomogr; 1992; 16(5):804-13. PubMed ID: 1522276
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility of a high-speed gamma-camera design using the high-yield-pileup-event-recovery method.
    Wong WH; Li H; Uribe J; Baghaei H; Wang Y; Yokoyama S
    J Nucl Med; 2001 Apr; 42(4):624-32. PubMed ID: 11337552
    [TBL] [Abstract][Full Text] [Related]  

  • 14. NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes.
    Kemp BJ; Kim C; Williams JJ; Ganin A; Lowe VJ;
    J Nucl Med; 2006 Dec; 47(12):1960-7. PubMed ID: 17138738
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The design of an animal PET: flexible geometry for achieving optimal spatial resolution or high sensitivity.
    Weber S; Terstegge A; Herzog H; Reinartz R; Reinhart P; Rongen F; Müller-Gärtner HW; Halling H
    IEEE Trans Med Imaging; 1997 Oct; 16(5):684-9. PubMed ID: 9368124
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measuring the imaged-object distance with a stationary high-spatial-resolution scintillation camera.
    Uzunov N; Bello M; Boccaccio P; Moschini G; Bollini D; de Notaristefani F
    Phys Med Biol; 2006 May; 51(9):N199-204. PubMed ID: 16625030
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Three-dimensional positron emission tomography imaging with 124I and 86Y.
    Vandenberghe S
    Nucl Med Commun; 2006 Mar; 27(3):237-45. PubMed ID: 16479243
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner.
    Wang Y; Seidel J; Tsui BM; Vaquero JJ; Pomper MG
    J Nucl Med; 2006 Nov; 47(11):1891-900. PubMed ID: 17079824
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance characteristics of a whole-body positron tomograph.
    Spinks TJ; Guzzardi R; Bellina CR
    J Nucl Med; 1988 Nov; 29(11):1833-41. PubMed ID: 3141597
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Design concepts and preliminary performances of stationary-sampling whole-body high-resolution positron emission tomography: HEADTOME IV].
    Kanno I; Iida H; Miura S; Yamamoto S; Amano M; Hirose Y; Murakami M; Takahashi K; Sasaki H; Shishido F
    Kaku Igaku; 1989 Apr; 26(4):477-85. PubMed ID: 2788759
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.