These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
223 related articles for article (PubMed ID: 23423726)
1. Transpulmonary thermodilution cardiac output measurement is not affected by severe pulmonary oedema: a newborn animal study. Nusmeier A; Vrancken S; de Boode WP; van der Hoeven JG; Lemson J Br J Anaesth; 2013 Aug; 111(2):286-92. PubMed ID: 23423726 [TBL] [Abstract][Full Text] [Related]
2. Effects of extravascular lung water on the measurement of transpulmonary thermodilution cardiac output in acute respiratory distress syndrome patients. Huang CC; Kao KC; Fu JY; Hsieh MJ J Cardiothorac Vasc Anesth; 2011 Jun; 25(3):481-5. PubMed ID: 20829067 [TBL] [Abstract][Full Text] [Related]
3. Cardiac output can be measured with the transpulmonary thermodilution method in a paediatric animal model with a left-to-right shunt. Nusmeier A; de Boode WP; Hopman JC; Schoof PH; van der Hoeven JG; Lemson J Br J Anaesth; 2011 Sep; 107(3):336-43. PubMed ID: 21642643 [TBL] [Abstract][Full Text] [Related]
4. Comparison of pulmonary artery and transpulmonary thermodilution cardiac output measurements in unsedated newborn calves. Kutter AP; Jud Schefer RS; Bircher B; Bleul U; Bettschart-Wolfensberger R Vet Anaesth Analg; 2015 Nov; 42(6):614-22. PubMed ID: 25689575 [TBL] [Abstract][Full Text] [Related]
5. Validation of extravascular lung water measurement by transpulmonary thermodilution in a pediatric animal model. Nusmeier A; Vrancken S; de Boode WP; van der Hoeven JG; Lemson J Pediatr Crit Care Med; 2014 Jun; 15(5):e226-33. PubMed ID: 24717901 [TBL] [Abstract][Full Text] [Related]
6. Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model. Lemson J; de Boode WP; Hopman JC; Singh SK; van der Hoeven JG Pediatr Crit Care Med; 2008 May; 9(3):313-9. PubMed ID: 18446111 [TBL] [Abstract][Full Text] [Related]
7. Estimation of extravascular lung water using the transpulmonary ultrasound dilution (TPUD) method: a validation study in neonatal lambs. Vrancken SL; Nusmeier A; Hopman JC; Liem KD; van der Hoeven JG; Lemson J; van Heijst AF; de Boode WP J Clin Monit Comput; 2016 Dec; 30(6):985-994. PubMed ID: 26563187 [TBL] [Abstract][Full Text] [Related]
8. Influence of extravascular lung water on transpulmonary thermodilution-derived cardiac output measurement. Pohl T; Kozieras J; Sakka SG Intensive Care Med; 2008 Mar; 34(3):533-7. PubMed ID: 17982741 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of agreement and trending ability between transpulmonary thermodilution and calibrated pulse contour and pulse power cardiac output monitoring methods against pulmonary artery thermodilution in anesthetized dogs. Kutter AP; Bettschart-Wolfensberger R; Romagnoli N; Bektas RN J Vet Emerg Crit Care (San Antonio); 2016 Jul; 26(4):531-40. PubMed ID: 26754858 [TBL] [Abstract][Full Text] [Related]
17. Effects of cardiac output levels on the measurement of transpulmonary thermodilution cardiac output in patients with acute respiratory distress syndrome. Huang CC; Chen NH; Li LF; Yang CT; Hsiao HF; Chen YH; Lin HL; Kao KC J Trauma Acute Care Surg; 2012 Nov; 73(5):1236-41. PubMed ID: 22914086 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of Cardiac Index and Extravascular Lung Water After Single-Lung Transplantation Using the Transpulmonary Thermodilution Technique by the PiCCO2 Device. Tran-Dinh A; Augustin P; Dufour G; Lasocki S; Allou N; Thabut G; Castier Y; Montravers P; Desmard M J Cardiothorac Vasc Anesth; 2018 Aug; 32(4):1731-1735. PubMed ID: 29203299 [TBL] [Abstract][Full Text] [Related]
19. Computed tomography to estimate cardiac preload and extravascular lung water. A retrospective analysis in critically ill patients. Saugel B; Holzapfel K; Stollfuss J; Schuster T; Phillip V; Schultheiss C; Schmid RM; Huber W Scand J Trauma Resusc Emerg Med; 2011 May; 19():31. PubMed ID: 21605380 [TBL] [Abstract][Full Text] [Related]
20. Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model. Bajorat J; Hofmockel R; Vagts DA; Janda M; Pohl B; Beck C; Noeldge-Schomburg G Eur J Anaesthesiol; 2006 Jan; 23(1):23-30. PubMed ID: 16390561 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]