These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 23425016)

  • 1. Long-term stability of angle-stable versus conventional locked intramedullary nails in distal tibia fractures.
    Wähnert D; Stolarczyk Y; Hoffmeier KL; Raschke MJ; Hofmann GO; Mückley T
    BMC Musculoskelet Disord; 2013 Feb; 14():66. PubMed ID: 23425016
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The primary stability of angle-stable versus conventional locked intramedullary nails.
    Wähnert D; Stolarczyk Y; Hoffmeier KL; Raschke MJ; Hofmann GO; Mückley T
    Int Orthop; 2012 May; 36(5):1059-64. PubMed ID: 22127384
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study.
    Gueorguiev B; Ockert B; Schwieger K; Wähnert D; Lawson-Smith M; Windolf M; Stoffel K
    J Orthop Trauma; 2011 Jun; 25(6):340-6. PubMed ID: 21577069
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
    Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures.
    Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P
    J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Angular stable locking in a novel intramedullary nail improves construct stability in a distal tibia fracture model.
    Zderic I; Gueorguiev B; Blauth M; Weber A; Koch R; Dauwe J; Schader JF; Stoffel K; Finkemeier C; Hessmann M
    Injury; 2022 Mar; 53(3):878-884. PubMed ID: 34782117
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
    Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
    Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study.
    Horn J; Linke B; Höntzsch D; Gueorguiev B; Schwieger K
    Injury; 2009 Jul; 40(7):767-71. PubMed ID: 19450799
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis.
    Kuhn S; Greenfield J; Arand C; Jarmolaew A; Appelmann P; Mehler D; Rommens PM
    Injury; 2015 Oct; 46 Suppl 4():S99-S103. PubMed ID: 26542874
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new angle stable nailing concept for the treatment of distal tibia fractures.
    Kuhn S; Appelmann P; Pairon P; Mehler D; Hartmann F; Rommens PM
    Int Orthop; 2014 Jun; 38(6):1255-60. PubMed ID: 24402556
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Angle-stable fixation of intramedullary nails using the Angular Stable Locking System® (ASLS)].
    Höntzsch D; Blauth M; Attal R
    Oper Orthop Traumatol; 2011 Dec; 23(5):387-96. PubMed ID: 22270968
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fatigue performance of angle-stable tibial nail interlocking screws.
    Lenz M; Gueorguiev B; Richards RG; Mückley T; Hofmann GO; Höntzsch D; Windolf M
    Int Orthop; 2013 Jan; 37(1):113-8. PubMed ID: 22875484
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interlocking screw configuration influences distal tibial fracture stability in torsional loading after intramedullary nailing.
    Lowenberg DW; DeBaun MR; Behn A; Sox-Harris A
    Eur J Orthop Surg Traumatol; 2020 Oct; 30(7):1205-1213. PubMed ID: 32367222
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical comparison of intramedullar versus extramedullar stabilization of intra-articular tibial plateau fractures.
    Högel F; Hoffmann S; Panzer S; Wimber J; Bühren V; Augat P
    Arch Orthop Trauma Surg; 2013 Jan; 133(1):59-64. PubMed ID: 23076657
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Polyaxial Screws in Locked Plating of Tibial Pilon Fractures.
    Yenna ZC; Bhadra AK; Ojike NI; Burden RL; Voor MJ; Roberts CS
    Orthopedics; 2015 Aug; 38(8):e663-7. PubMed ID: 26270750
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Intramedullary nailing of the distal tibia. Does angular stable locking make a difference?].
    Augat P; Bühren V
    Unfallchirurg; 2015 Apr; 118(4):311-7. PubMed ID: 25835206
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.
    Strauss EJ; Alfonso D; Kummer FJ; Egol KA; Tejwani NC
    J Orthop Trauma; 2007 Mar; 21(3):172-7. PubMed ID: 17473753
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of angular stability and other locking parameters on the mechanical performance of intramedullary nails.
    Hoffmann S; Gerber C; von Oldenburg G; Kessler M; Stephan D; Augat P
    Biomed Tech (Berl); 2015 Apr; 60(2):157-64. PubMed ID: 25581739
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails.
    Erden T; Kapicioglu M; Demirtas A; Bilsel K; Akpinar F; Kuduz H
    Acta Orthop Traumatol Turc; 2019 Nov; 53(6):490-496. PubMed ID: 31562026
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of distal interlocking screw number and position after intramedullary nailing of distal tibial fractures: a biomechanical study simulating immediate weight-bearing.
    Chan DS; Nayak AN; Blaisdell G; James CR; Denard A; Miles J; Santoni BG
    J Orthop Trauma; 2015 Feb; 29(2):98-104. PubMed ID: 25072288
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.