These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 23428836)

  • 1. Patient-specific simulations of stenting procedures in coronary bifurcations: two clinical cases.
    Morlacchi S; Colleoni SG; Cárdenes R; Chiastra C; Diez JL; Larrabide I; Migliavacca F
    Med Eng Phys; 2013 Sep; 35(9):1272-81. PubMed ID: 23428836
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computational replication of the patient-specific stenting procedure for coronary artery bifurcations: From OCT and CT imaging to structural and hemodynamics analyses.
    Chiastra C; Wu W; Dickerhoff B; Aleiou A; Dubini G; Otake H; Migliavacca F; LaDisa JF
    J Biomech; 2016 Jul; 49(11):2102-2111. PubMed ID: 26655589
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stent deformation, physical stress, and drug elution obtained with provisional stenting, conventional culotte and Tryton-based culotte to treat bifurcations: a virtual simulation study.
    Morlacchi S; Chiastra C; Cutrì E; Zunino P; Burzotta F; Formaggia L; Dubini G; Migliavacca F
    EuroIntervention; 2014; 9(12):1441-53. PubMed ID: 24755384
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Kissing balloon or sequential dilation of the side branch and main vessel for provisional stenting of bifurcations: lessons from micro-computed tomography and computational simulations.
    Foin N; Torii R; Mortier P; De Beule M; Viceconte N; Chan PH; Davies JE; Xu XY; Krams R; Di Mario C
    JACC Cardiovasc Interv; 2012 Jan; 5(1):47-56. PubMed ID: 22230150
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sequential structural and fluid dynamic numerical simulations of a stented bifurcated coronary artery.
    Morlacchi S; Chiastra C; Gastaldi D; Pennati G; Dubini G; Migliavacca F
    J Biomech Eng; 2011 Dec; 133(12):121010. PubMed ID: 22206427
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Randomized study of the crush technique versus provisional side-branch stenting in true coronary bifurcations: the CACTUS (Coronary Bifurcations: Application of the Crushing Technique Using Sirolimus-Eluting Stents) Study.
    Colombo A; Bramucci E; Saccà S; Violini R; Lettieri C; Zanini R; Sheiban I; Paloscia L; Grube E; Schofer J; Bolognese L; Orlandi M; Niccoli G; Latib A; Airoldi F
    Circulation; 2009 Jan; 119(1):71-8. PubMed ID: 19103990
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical Interaction of an Expanding Coiled Stent with a Plaque-Containing Arterial Wall: A Finite Element Analysis.
    Welch TR; Eberhart RC; Banerjee S; Chuong CJ
    Cardiovasc Eng Technol; 2016 Mar; 7(1):58-68. PubMed ID: 26621671
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Examination of stent deformation and gap formation after complex stenting of left main coronary artery bifurcations using microfocus computed tomography.
    Murasato Y; Hikichi Y; Horiuchi M
    J Interv Cardiol; 2009 Apr; 22(2):135-44. PubMed ID: 19379472
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Patient-specific finite element analysis of carotid artery stenting: a focus on vessel modeling.
    Auricchio F; Conti M; Ferrara A; Morganti S; Reali A
    Int J Numer Method Biomed Eng; 2013 Jun; 29(6):645-64. PubMed ID: 23729192
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling.
    LaDisa JF; Olson LE; Douglas HA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2006 Jun; 5():40. PubMed ID: 16780592
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in bifurcation lesions treated with a single-stenting technique: six-month angiographic and 12-month clinical results of the drug-eluting balloon in bifurcations trial.
    Stella PR; Belkacemi A; Dubois C; Nathoe H; Dens J; Naber C; Adriaenssens T; van Belle E; Doevendans P; Agostoni P
    Catheter Cardiovasc Interv; 2012 Dec; 80(7):1138-46. PubMed ID: 22422607
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stenting techniques for patients with bifurcation coronary artery disease.
    Lee MS; Finch W
    Rev Cardiovasc Med; 2011; 12(4):231-9. PubMed ID: 22249515
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery.
    Liang DK; Yang DZ; Qi M; Wang WQ
    Int J Cardiol; 2005 Oct; 104(3):314-8. PubMed ID: 16186062
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Frequency-domain optical coherence tomography findings in patients with bifurcated lesions undergoing provisional stenting.
    Burzotta F; Talarico GP; Trani C; De Maria GL; Pirozzolo G; Niccoli G; Leone AM; Saffioti S; Porto I; Crea F
    Eur Heart J Cardiovasc Imaging; 2014 May; 15(5):547-55. PubMed ID: 24255135
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The carina angle-new geometrical parameter associated with periprocedural side branch compromise and the long-term results in coronary bifurcation lesions with main vessel stenting only.
    Gil RJ; Vassilev D; Formuszewicz R; Rusicka-Piekarz T; Doganov A
    J Interv Cardiol; 2009 Dec; 22(6):E1-E10. PubMed ID: 19702678
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Modeling stented coronary arteries: where we are, where to go.
    Morlacchi S; Migliavacca F
    Ann Biomed Eng; 2013 Jul; 41(7):1428-44. PubMed ID: 23090621
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Finite element evaluation of artery damage in deployment of polymeric stent with pre- and post-dilation.
    He R; Zhao LG; Silberschmidt VV; Liu Y; Vogt F
    Biomech Model Mechanobiol; 2020 Feb; 19(1):47-60. PubMed ID: 31317295
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemodynamics of Stent Implantation Procedures in Coronary Bifurcations: An In Vitro Study.
    Brindise MC; Chiastra C; Burzotta F; Migliavacca F; Vlachos PP
    Ann Biomed Eng; 2017 Mar; 45(3):542-553. PubMed ID: 27460012
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Modelling of the provisional side-branch stenting approach for the treatment of atherosclerotic coronary bifurcations: effects of stent positioning.
    Gastaldi D; Morlacchi S; Nichetti R; Capelli C; Dubini G; Petrini L; Migliavacca F
    Biomech Model Mechanobiol; 2010 Oct; 9(5):551-61. PubMed ID: 20155479
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Finite element analysis of the percutaneous coronary intervention in a coronary bifurcation.
    Bukała JK; Małachowski J; Kwiatkowski P
    Acta Bioeng Biomech; 2014; 16(4):23-31. PubMed ID: 25597960
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.