  • 1. Validation of a new method based on ultrasound velocity dilution to measure cardiac output in paediatric patients.
    Floh AA; La Rotta G; Wermelt JZ; Bastero-Miñón P; Sivarajan VB; Humpl T
    Intensive Care Med; 2013 May; 39(5):926-33. PubMed ID: 23430016
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.
    Lindberg L; Johansson S; Perez-de-Sa V
    Pediatr Crit Care Med; 2014 Feb; 15(2):139-47. PubMed ID: 24366506
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of cardiac output measurement by ultrasound dilution technique with pulmonary artery thermodilution in a pediatric animal model.
    Darling E; Thuramalla N; Searles B
    Pediatr Cardiol; 2011 Jun; 32(5):585-9. PubMed ID: 21359950
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of cardiac output by ultrasound dilution technique in infants and children: a validation study against direct Fick principle.
    Boehne M; Baustert M; Paetzel V; Köditz H; Schoof S; Happel CM; Bertram H
    Br J Anaesth; 2014 Mar; 112(3):469-76. PubMed ID: 24335550
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ultrasound dilution: an accurate means of determining cardiac output in children.
    Crittendon I; Dreyer WJ; Decker JA; Kim JJ
    Pediatr Crit Care Med; 2012 Jan; 13(1):42-6. PubMed ID: 21499176
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flow-regulated extracorporeal arteriovenous tubing loop for cardiac output measurements by ultrasound velocity dilution: validation in post-cardiac surgery intensive care unit patients.
    Eremenko AA; Safarov PN
    ASAIO J; 2010; 56(6):522-6. PubMed ID: 21245798
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of a new cardiac output ultrasound dilution method with thermodilution technique in adult patients under general anesthesia.
    Tsutsui M; Matsuoka N; Ikeda T; Sanjo Y; Kazama T
    J Cardiothorac Vasc Anesth; 2009 Dec; 23(6):835-40. PubMed ID: 19464193
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.
    Chang AC; Kulik TJ; Hickey PR; Wessel DL
    Crit Care Med; 1993 Sep; 21(9):1369-75. PubMed ID: 8370302
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of cardiac output by thoracic impedance and direct fick in children with congenital heart disease undergoing diagnostic cardiac catheterization.
    Taylor K; La Rotta G; McCrindle BW; Manlhiot C; Redington A; Holtby H
    J Cardiothorac Vasc Anesth; 2011 Oct; 25(5):776-9. PubMed ID: 21684761
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of a novel ultrasound dilution method to measure cardiac output during hemodialysis.
    Kisloukhine VV; Dean DA
    ASAIO J; 1996; 42(5):M906-7. PubMed ID: 8945018
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lack of agreement between thermodilution and fick cardiac output in critically ill patients.
    Dhingra VK; Fenwick JC; Walley KR; Chittock DR; Ronco JJ
    Chest; 2002 Sep; 122(3):990-7. PubMed ID: 12226045
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of a new method to measure cardiac output during extracorporeal detoxification.
    Nikiforov YV; Kisluchine VV; Chaus NI
    ASAIO J; 1996; 42(5):M903-5. PubMed ID: 8945017
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cardiac output measurement using an ultrasound dilution method: a validation study in ventilated piglets.
    de Boode WP; van Heijst AF; Hopman JC; Tanke RB; van der Hoeven HG; Liem KD
    Pediatr Crit Care Med; 2010 Jan; 11(1):103-8. PubMed ID: 19593242
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility and Accuracy of Cardiac Right-to-Left-Shunt Detection in Children by New Transpulmonary Ultrasound Dilution Method.
    Boehne M; Baustert M; Paetzel V; Boethig D; Köditz H; Dennhardt N; Beerbaum P; Bertram H
    Pediatr Cardiol; 2017 Jan; 38(1):135-148. PubMed ID: 27826705
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants.
    Tibby SM; Hatherill M; Marsh MJ; Morrison G; Anderson D; Murdoch IA
    Intensive Care Med; 1997 Sep; 23(9):987-91. PubMed ID: 9347372
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle.
    Pauli C; Fakler U; Genz T; Hennig M; Lorenz HP; Hess J
    Intensive Care Med; 2002 Jul; 28(7):947-52. PubMed ID: 12122535
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Methods in pharmacology: measurement of cardiac output.
    Geerts BF; Aarts LP; Jansen JR
    Br J Clin Pharmacol; 2011 Mar; 71(3):316-30. PubMed ID: 21284692
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardiac output measurements in congenital heart disease: validation of a simple, portable Doppler method.
    Gentles TL; Neutze JM; Caulder AL; Greene ER
    J Ultrasound Med; 2001 Apr; 20(4):365-70. PubMed ID: 11316315
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of cardiac output determined by an ultrasound velocity dilution cardiac output method and by the lithium dilution cardiac output method in juvenile horses with experimentally induced hypovolemia.
    Shih AC; Queiroz P; Vigani A; Da Cunha A; Pariaut R; Ricco C; Bornkamp J; Garcia-Pereira F; Bandt C
    Am J Vet Res; 2014 Jun; 75(6):565-71. PubMed ID: 24866512
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Measuring cardiac output in infants with the Fick principle via oxygen consumption: animal experiment and clinical results].
    Pscheidl E; Buheitel G; Schywalsky M; Braun GG
    Klin Padiatr; 1994; 206(2):86-91. PubMed ID: 8196312
    [TBL] [Abstract][Full Text] [Related]  