These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

322 related articles for article (PubMed ID: 23433047)

  • 1. Renal transplantation after ex vivo normothermic perfusion: the first clinical study.
    Nicholson ML; Hosgood SA
    Am J Transplant; 2013 May; 13(5):1246-52. PubMed ID: 23433047
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Protocol of a randomised controlled, open-label trial of ex vivo normothermic perfusion versus static cold storage in donation after circulatory death renal transplantation.
    Hosgood SA; Saeb-Parsy K; Wilson C; Callaghan C; Collett D; Nicholson ML
    BMJ Open; 2017 Jan; 7(1):e012237. PubMed ID: 28115329
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Normothermic perfusion of extended criteria donor kidneys utilizing an ex vivo machine.
    Hossain MA; Bagul A
    Am J Transplant; 2013 Sep; 13(9):2501-2. PubMed ID: 23915115
    [No Abstract]   [Full Text] [Related]  

  • 4. Dissemination of a novel organ perfusion technique: ex vivo normothermic perfusion of deceased donor kidneys.
    Chandak P; Phillips BL; Uwechue R; Thompson E; Bates L; Ibrahim I; Sewpaul A; Figueiredo R; Olsburgh J; Hosgood S; Nicholson ML; Wilson C; Callaghan CJ
    Artif Organs; 2019 Nov; 43(11):E308-E319. PubMed ID: 31087667
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Re: Renal transplantation after ex vivo normothermic perfusion: the first clinical study.
    Goldfarb DA
    J Urol; 2013 Oct; 190(4):1334. PubMed ID: 24029344
    [No Abstract]   [Full Text] [Related]  

  • 6. The first clinical case of intermediate ex vivo normothermic perfusion in renal transplantation.
    Hosgood SA; Nicholson ML
    Am J Transplant; 2014 Jul; 14(7):1690-2. PubMed ID: 24816186
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Machine perfusion versus cold storage for preservation of kidneys from expanded criteria donors after brain death.
    Treckmann J; Moers C; Smits JM; Gallinat A; Maathuis MH; van Kasterop-Kutz M; Jochmans I; Homan van der Heide JJ; Squifflet JP; van Heurn E; Kirste GR; Rahmel A; Leuvenink HG; Pirenne J; Ploeg RJ; Paul A
    Transpl Int; 2011 Jun; 24(6):548-54. PubMed ID: 21332580
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ex vivo normothermic perfusion for quality assessment of marginal donor kidney transplants.
    Hosgood SA; Barlow AD; Hunter JP; Nicholson ML
    Br J Surg; 2015 Oct; 102(11):1433-40. PubMed ID: 26313559
    [TBL] [Abstract][Full Text] [Related]  

  • 9. First in man renal transplantation after ex vivo normothermic perfusion.
    Hosgood SA; Nicholson ML
    Transplantation; 2011 Oct; 92(7):735-8. PubMed ID: 21841540
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Successful Transplantation of Human Kidneys Deemed Untransplantable but Resuscitated by Ex Vivo Normothermic Machine Perfusion.
    Hosgood SA; Saeb-Parsy K; Hamed MO; Nicholson ML
    Am J Transplant; 2016 Nov; 16(11):3282-3285. PubMed ID: 27273794
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transplantation of kidneys from uncontrolled donation after circulatory determination of death: comparison with brain death donors with or without extended criteria and impact of normothermic regional perfusion.
    Demiselle J; Augusto JF; Videcoq M; Legeard E; Dubé L; Templier F; Renaudin K; Sayegh J; Karam G; Blancho G; Dantal J
    Transpl Int; 2016 Apr; 29(4):432-42. PubMed ID: 26606511
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Viability assessment and utilization of declined donor kidneys with rhabdomyolysis using ex vivo normothermic perfusion without preimplantation biopsy.
    Pearson R; Asher J; Jackson A; Mark PB; Shumeyko V; Clancy MJ
    Am J Transplant; 2021 Mar; 21(3):1317-1321. PubMed ID: 33021059
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Combined Ex Vivo Hypothermic and Normothermic Perfusion for Assessment of High-risk Deceased Donor Human Kidneys for Transplantation.
    Kabagambe SK; Palma IP; Smolin Y; Boyer T; Palma I; Sageshima J; Troppmann C; Santhanakrishnan C; McVicar JP; Jen KY; Nuño M; Perez RV
    Transplantation; 2019 Feb; 103(2):392-400. PubMed ID: 29952816
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cold Pulsatile Machine Perfusion Versus Static Cold Storage for Kidneys Donated After Circulatory Death: A Multicenter Randomized Controlled Trial.
    Summers DM; Ahmad N; Randle LV; O'Sullivan AM; Johnson RJ; Collett D; Attia M; Clancy M; Tavakoli A; Akyol M; Jamieson NV; Bradley JA; J E Watson C
    Transplantation; 2020 May; 104(5):1019-1025. PubMed ID: 31403552
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous Normothermic Ex Vivo Kidney Perfusion Improves Graft Function in Donation After Circulatory Death Pig Kidney Transplantation.
    Kaths JM; Echeverri J; Chun YM; Cen JY; Goldaracena N; Linares I; Dingwell LS; Yip PM; John R; Bagli D; Mucsi I; Ghanekar A; Grant DR; Robinson LA; Selzner M
    Transplantation; 2017 Apr; 101(4):754-763. PubMed ID: 27467537
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hypothermic Machine Perfusion Results in a Marginal Kidney Transplant Programme.
    Gómez-Dos Santos V; Ruiz Hernández M; Burgos-Revilla FJ
    Eur Urol Focus; 2018 Mar; 4(2):163-168. PubMed ID: 29929872
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Normothermic Ex Vivo Kidney Perfusion Improves Early DCD Graft Function Compared With Hypothermic Machine Perfusion and Static Cold Storage.
    Urbanellis P; Hamar M; Kaths JM; Kollmann D; Linares I; Mazilescu L; Ganesh S; Wiebe A; Yip PM; John R; Konvalinka A; Mucsi I; Ghanekar A; Bagli DJ; Robinson LA; Selzner M
    Transplantation; 2020 May; 104(5):947-955. PubMed ID: 31815900
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The use of ex-vivo normothermic perfusion for the resuscitation and assessment of human kidneys discarded because of inadequate in situ perfusion.
    Hosgood SA; Barlow AD; Dormer J; Nicholson ML
    J Transl Med; 2015 Oct; 13():329. PubMed ID: 26474973
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of outcomes in renal transplantation with hypothermic machine perfusion for the preservation of kidneys from expanded criteria donors.
    Savoye E; Macher MA; Videcoq M; Gatault P; Hazzan M; Abboud I; Thierry A; Bertrand D; Drouin S; Sayegh J; Barrou B; Badet L; Bastien O; Huot O; Lamotte C; Logerot H; Legeai C; Antoine C
    Clin Transplant; 2019 May; 33(5):e13536. PubMed ID: 30869162
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of quality of kidneys from donation after circulatory death/expanded criteria donors by parameters of machine perfusion.
    Chen G; Wang C; Zhao Y; Qiu L; Yuan X; Qiu J; Wang C; He X; Chen L
    Nephrology (Carlton); 2018 Feb; 23(2):103-106. PubMed ID: 27888556
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.