These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study. Larghi A; Iglesias-Garcia J; Poley JW; Monges G; Petrone MC; Rindi G; Abdulkader I; Arcidiacono PG; Costamagna G; Biermann K; Bories E; Doglioni C; Dominguez-Muñoz JE; Hassan C; Bruno M; Giovannini M Surg Endosc; 2013 Oct; 27(10):3733-8. PubMed ID: 23644834 [TBL] [Abstract][Full Text] [Related]
24. Comparative accuracy of needle sizes and designs for EUS tissue sampling of solid pancreatic masses: a network meta-analysis. Facciorusso A; Wani S; Triantafyllou K; Tziatzios G; Cannizzaro R; Muscatiello N; Singh S Gastrointest Endosc; 2019 Dec; 90(6):893-903.e7. PubMed ID: 31310744 [TBL] [Abstract][Full Text] [Related]
25. 22-Gauge biopsy needles have a better histological diagnostic yield in the discrimination of specific pancreatic solid neoplasms. Jiang H; Guo J; Wang K; Zhu H; Chen J; Xu C; Wang D; Jin Z Scand J Gastroenterol; 2019 Jan; 54(1):101-107. PubMed ID: 30731044 [TBL] [Abstract][Full Text] [Related]
26. Diagnostic ability of EUS-FNA for pancreatic solid lesions with conventional 22-gauge needle using the slow pull technique: a prospective study. Kin T; Katanuma A; Yane K; Takahashi K; Osanai M; Takaki R; Matsumoto K; Gon K; Matsumori T; Tomonari A; Maguchi H; Shinohara T; Nojima M Scand J Gastroenterol; 2015 Jul; 50(7):900-7. PubMed ID: 25732902 [TBL] [Abstract][Full Text] [Related]
27. Comparison of 22G standard and Franseen needles in endoscopic ultrasound-guided fine-needle aspiration for diagnosing pancreatic mass lesions: Study protocol for a controlled trial. Itonaga M; Yasukawa S; Shimokawa T; Takenaka M; Fukutake N; Ogura T; Sakagami J; Shiomi H; Okura Y; Inatomi O; Matsumoto H; Kurita A; Suzuki A; Tanaka K; Kitano M Trials; 2019 Dec; 20(1):816. PubMed ID: 31888733 [TBL] [Abstract][Full Text] [Related]
28. Diagnostic yield of malignancy during EUS-guided FNA of solid lesions with and without a stylet: a prospective, single blind, randomized, controlled trial. Wani S; Early D; Kunkel J; Leathersich A; Hovis CE; Hollander TG; Kohlmeier C; Zelenka C; Azar R; Edmundowicz S; Collins B; Liu J; Hall M; Mullady D Gastrointest Endosc; 2012 Aug; 76(2):328-35. PubMed ID: 22695205 [TBL] [Abstract][Full Text] [Related]
29. Randomized trial comparing the Franseen and Fork-tip needles for EUS-guided fine-needle biopsy sampling of solid pancreatic mass lesions. Bang JY; Hebert-Magee S; Navaneethan U; Hasan MK; Hawes R; Varadarajulu S Gastrointest Endosc; 2018 Jun; 87(6):1432-1438. PubMed ID: 29305893 [TBL] [Abstract][Full Text] [Related]
30. Endoscopic ultrasound-guided tissue sampling by combined fine needle aspiration and trucut needle biopsy: a prospective study. Wittmann J; Kocjan G; Sgouros SN; Deheragoda M; Pereira SP Cytopathology; 2006 Feb; 17(1):27-33. PubMed ID: 16417562 [TBL] [Abstract][Full Text] [Related]
31. Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience. Yusuf TE; Ho S; Pavey DA; Michael H; Gress FG Endoscopy; 2009 May; 41(5):445-8. PubMed ID: 19418399 [TBL] [Abstract][Full Text] [Related]
32. Assessment of the technical performance of the flexible 19-gauge EUS-FNA needle. Varadarajulu S; Bang JY; Hebert-Magee S Gastrointest Endosc; 2012 Aug; 76(2):336-43. PubMed ID: 22817786 [TBL] [Abstract][Full Text] [Related]
33. Diagnosis of pancreatic neoplasia with EUS and FNA: a report of accuracy. Turner BG; Cizginer S; Agarwal D; Yang J; Pitman MB; Brugge WR Gastrointest Endosc; 2010 Jan; 71(1):91-8. PubMed ID: 19846087 [TBL] [Abstract][Full Text] [Related]
35. The cellularity yield of three different 22-gauge endoscopic ultrasound fine needle aspiration needles. Othman MO; Abdelfatah MM; Padilla O; Hussinat M; Elhanafi S; Eloliby M; Torabi A; Hakim N; Boman DA Diagn Cytopathol; 2017 May; 45(5):426-432. PubMed ID: 28261978 [TBL] [Abstract][Full Text] [Related]
37. Comparison of 22-gauge standard fine needle versus core biopsy needle for endoscopic ultrasound-guided sampling of suspected pancreatic cancer: a randomized crossover trial. Noh DH; Choi K; Gu S; Cho J; Jang KT; Woo YS; Lee KT; Lee JK; Lee KH Scand J Gastroenterol; 2018 Jan; 53(1):94-99. PubMed ID: 29065734 [TBL] [Abstract][Full Text] [Related]
38. Stylet slow-pull versus standard suction for endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic lesions: a multicenter randomized trial. Saxena P; El Zein M; Stevens T; Abdelgelil A; Besharati S; Messallam A; Kumbhari V; Azola A; Brainard J; Shin EJ; Lennon AM; Canto MI; Singh VK; Khashab MA Endoscopy; 2018 May; 50(5):497-504. PubMed ID: 29272906 [TBL] [Abstract][Full Text] [Related]
39. Per-Pass Performance Characteristics of Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Malignant Solid Pancreatic Masses in a Large Multicenter Cohort. Ge PS; Wani S; Watson RR; Sedarat A; Kim S; Marshall C; Wilson RH; Makker J; Mohamadnejad M; Komanduri S; Muthusamy VR Pancreas; 2018 Mar; 47(3):296-301. PubMed ID: 29401169 [TBL] [Abstract][Full Text] [Related]
40. Core needle versus standard needle for endoscopic ultrasound-guided biopsy of solid pancreatic masses: a randomized crossover study. Vanbiervliet G; Napoléon B; Saint Paul MC; Sakarovitch C; Wangermez M; Bichard P; Subtil C; Koch S; Grandval P; Gincul R; Karsenti D; Heyries L; Duchmann JC; Bourgaux JF; Levy M; Calament G; Fumex F; Pujol B; Lefort C; Poincloux L; Pagenault M; Bonin EA; Fabre M; Barthet M Endoscopy; 2014 Dec; 46(12):1063-70. PubMed ID: 25098612 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]