These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
44. Simplifying four-strand flexor tendon repair using double-stranded suture: a comparative ex vivo study on tensile strength and bulking. Low TH; Ahmad TS; Ng ES J Hand Surg Eur Vol; 2012 Feb; 37(2):101-8. PubMed ID: 21636621 [TBL] [Abstract][Full Text] [Related]
45. Comparison of elastic versus rigid suture material for peripheral sutures in tendon repair. Nozaki K; Mori R; Ryoke K; Uchio Y Clin Biomech (Bristol); 2012 Jun; 27(5):506-10. PubMed ID: 22172800 [TBL] [Abstract][Full Text] [Related]
46. Number of suture throws and its impact on the biomechanical properties of the four-strand cruciate locked flexor tendon repair with FiberWire. Le SV; Chiu S; Meineke RC; Williams P; Wongworawat MD J Hand Surg Eur Vol; 2012 Nov; 37(9):826-31. PubMed ID: 22618562 [TBL] [Abstract][Full Text] [Related]
47. Ex vivo biomechanical comparison of barbed suture and standard polypropylene suture for acute tendon laceration in a canine model. Duffy DJ; Main RP; Moore GE; Breur GJ; Millard RP Vet Comp Orthop Traumatol; 2015; 28(4):263-9. PubMed ID: 26037406 [TBL] [Abstract][Full Text] [Related]
48. Comparison of Flexor Tendon Suture Techniques Including 1 Using 10 Strands. Lee HI; Lee JS; Kim TH; Chang SH; Park MJ; Lee GJ J Hand Surg Am; 2015 Jul; 40(7):1369-76. PubMed ID: 26050206 [TBL] [Abstract][Full Text] [Related]
49. Effects of tension across the tendon repair site on tendon gap and ultimate strength. Wu YF; Tang JB J Hand Surg Am; 2012 May; 37(5):906-12. PubMed ID: 22386548 [TBL] [Abstract][Full Text] [Related]
50. The impact of fiberwire, fiberloop, and locking suture configuration on flexor tendon repairs. Haimovici L; Papafragkou S; Lee W; Dagum A; Hurst LC Ann Plast Surg; 2012 Oct; 69(4):468-70. PubMed ID: 22964669 [TBL] [Abstract][Full Text] [Related]
51. A barbed suture repair for flexor tendons: a novel technique with no exposed barbs. Joyce CW; Sugrue C; Chan JC; Delgado L; Zeugolis D; Carroll SM; Kelly JL Plast Reconstr Surg Glob Open; 2014 Oct; 2(10):e237. PubMed ID: 25426354 [TBL] [Abstract][Full Text] [Related]
52. A biomechanical comparison of a tendon repair device and 4 stranded, cruciate repair sutures for flexor tendon ruptured. Tantadprasert S; Jeeravipoolvarn P; Kosuwon W; Chaiyasivamongkon K J Med Assoc Thai; 2009 Nov; 92(11):1434-41. PubMed ID: 19938734 [TBL] [Abstract][Full Text] [Related]
53. The resistance of a four- and eight-strand suture technique to gap formation during tensile testing: an experimental study of repaired canine flexor tendons after 10 days of in vivo healing. Dinopoulos HT; Boyer MI; Burns ME; Gelberman RH; Silva MJ J Hand Surg Am; 2000 May; 25(3):489-98. PubMed ID: 10811754 [TBL] [Abstract][Full Text] [Related]
54. Biomechanical comparison of modified Kessler and running suture repair in 3 different animal tendons and in human flexor tendons. Hausmann JT; Vekszler G; Bijak M; Benesch T; Vécsei V; Gäbler C J Hand Surg Am; 2009 Jan; 34(1):93-101. PubMed ID: 19121736 [TBL] [Abstract][Full Text] [Related]
55. Investigation of locking configurations for tendon repair. Xie RG; Tang JB J Hand Surg Am; 2005 May; 30(3):461-5. PubMed ID: 15925152 [TBL] [Abstract][Full Text] [Related]
56. Analysis of a knotless flexor tendon repair using a multifilament stainless steel cable-crimp system. Gordon L; Matsui J; McDonald E; Gordon JA; Neimkin R J Hand Surg Am; 2013 Apr; 38(4):677-83. PubMed ID: 23453895 [TBL] [Abstract][Full Text] [Related]
57. Influence of barbed epitendinous sutures combined with a core locking-loop suture to repair experimental flexor tendon lacerations. Eby AC; Duffy DJ; Chang YJ; Gaffney L; Fisher MB; Moore GE Vet Surg; 2020 Dec; 49(8):1590-1599. PubMed ID: 32830868 [TBL] [Abstract][Full Text] [Related]
58. The biomechanical analysis of a tendon fixation device for flexor tendon repair. Su BW; Protopsaltis TS; Koff MF; Chang KP; Strauch RJ; Crow SA; Rosenwasser MP J Hand Surg Am; 2005 Mar; 30(2):237-45. PubMed ID: 15781345 [TBL] [Abstract][Full Text] [Related]
59. Effects of direction of tendon lacerations on strength of tendon repairs. Tan J; Wang B; Xu Y; Tang JB J Hand Surg Am; 2003 Mar; 28(2):237-42. PubMed ID: 12671854 [TBL] [Abstract][Full Text] [Related]
60. Effects of locking area on strength of 2- and 4-strand locking tendon repairs. Xie RG; Xue HG; Gu JH; Tan J; Tang JB J Hand Surg Am; 2005 May; 30(3):455-60. PubMed ID: 15925151 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]