These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

258 related articles for article (PubMed ID: 23436701)

  • 1. Mass spectrometry-based methods to study protein architecture and dynamics.
    Kaltashov IA; Bobst CE; Abzalimov RR
    Protein Sci; 2013 May; 22(5):530-44. PubMed ID: 23436701
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Protein conformations, interactions, and H/D exchange.
    Maier CS; Deinzer ML
    Methods Enzymol; 2005; 402():312-60. PubMed ID: 16401514
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterizing rapid, activity-linked conformational transitions in proteins via sub-second hydrogen deuterium exchange mass spectrometry.
    Resetca D; Wilson DJ
    FEBS J; 2013 Nov; 280(22):5616-25. PubMed ID: 23663649
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Unraveling the dynamics of protein interactions with quantitative mass spectrometry.
    Ramisetty SR; Washburn MP
    Crit Rev Biochem Mol Biol; 2011 Jun; 46(3):216-28. PubMed ID: 21438726
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of mass spectrometry based hydrogen deuterium exchange methods for probing the cyclophilin A cyclosporin complex.
    Esswein ST; Florance HV; Baillie L; Lippens J; Barran PE
    J Chromatogr A; 2010 Oct; 1217(43):6709-17. PubMed ID: 20557890
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hydrogen/deuterium exchange in parallel with acid/base induced protein conformational change in electrospray droplets.
    Kharlamova A; Fisher CM; McLuckey SA
    J Mass Spectrom; 2014 Jun; 49(6):437-44. PubMed ID: 24913396
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Time-resolved ElectroSpray Ionization Hydrogen-deuterium Exchange Mass Spectrometry for Studying Protein Structure and Dynamics.
    Lento C; Zhu S; Brown KA; Knox R; Liuni P; Wilson DJ
    J Vis Exp; 2017 Apr; (122):. PubMed ID: 28448048
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Probing backbone dynamics with hydrogen/deuterium exchange mass spectrometry.
    Singh H; Busenlehner LS
    Methods Mol Biol; 2014; 1084():81-99. PubMed ID: 24061917
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Conformational analysis of g protein-coupled receptor signaling by hydrogen/deuterium exchange mass spectrometry.
    Li S; Lee SY; Chung KY
    Methods Enzymol; 2015; 557():261-78. PubMed ID: 25950969
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hydrogen exchange mass spectrometry for the analysis of protein dynamics.
    Wales TE; Engen JR
    Mass Spectrom Rev; 2006; 25(1):158-70. PubMed ID: 16208684
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated hydrogen/deuterium exchange electron transfer dissociation high resolution mass spectrometry measured at single-amide resolution.
    Landgraf RR; Chalmers MJ; Griffin PR
    J Am Soc Mass Spectrom; 2012 Feb; 23(2):301-9. PubMed ID: 22131230
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Contemporary hydrogen deuterium exchange mass spectrometry.
    Oganesyan I; Lento C; Wilson DJ
    Methods; 2018 Jul; 144():27-42. PubMed ID: 29704663
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hydrogen-Deuterium Exchange Mass Spectrometry to Study Protein Complexes.
    Kochert BA; Iacob RE; Wales TE; Makriyannis A; Engen JR
    Methods Mol Biol; 2018; 1764():153-171. PubMed ID: 29605914
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Top-Down Analysis of In-Source HDX of Native Protein Ions.
    Sanguantrakun N; Chanthamontri C; Gross ML
    J Am Soc Mass Spectrom; 2020 May; 31(5):1151-1154. PubMed ID: 32275420
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Higher order structure characterization of protein therapeutics by hydrogen/deuterium exchange mass spectrometry.
    Huang RY; Chen G
    Anal Bioanal Chem; 2014 Oct; 406(26):6541-58. PubMed ID: 24948090
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hydrogen/deuterium exchange-mass spectrometry: a powerful tool for probing protein structure, dynamics and interactions.
    Tsutsui Y; Wintrode PL
    Curr Med Chem; 2007; 14(22):2344-58. PubMed ID: 17896983
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection and characterization of altered conformations of protein pharmaceuticals using complementary mass spectrometry-based approaches.
    Bobst CE; Abzalimov RR; Houde D; Kloczewiak M; Mhatre R; Berkowitz SA; Kaltashov IA
    Anal Chem; 2008 Oct; 80(19):7473-81. PubMed ID: 18729476
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Strong anion exchange for studying protein-DNA interactions by H/D exchange mass spectrometry.
    Sperry JB; Wilcox JM; Gross ML
    J Am Soc Mass Spectrom; 2008 Jun; 19(6):887-90. PubMed ID: 18417359
    [TBL] [Abstract][Full Text] [Related]  

  • 19. On-tissue Direct Monitoring of Global Hydrogen/Deuterium Exchange by MALDI Mass Spectrometry: Tissue Deuterium Exchange Mass Spectrometry (TDXMS).
    Quanico J; Franck J; Salzet M; Fournier I
    Mol Cell Proteomics; 2016 Oct; 15(10):3321-3330. PubMed ID: 27512083
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hydrogen-deuterium exchange mass spectrometry reveals folding and allostery in protein-protein interactions.
    Ramirez-Sarmiento CA; Komives EA
    Methods; 2018 Jul; 144():43-52. PubMed ID: 29627358
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.