These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 2343731)

  • 1. Laboratory evaluation of heat and moisture exchangers. Assessment of the Draft International Standard (ISO/DIS 9360) in practice.
    Eckerbom B; Lindholm CE
    Acta Anaesthesiol Scand; 1990 May; 34(4):291-5. PubMed ID: 2343731
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients.
    Brusasco C; Corradi F; Vargas M; Bona M; Bruno F; Marsili M; Simonassi F; Santori G; Severgnini P; Kacmarek RM; Pelosi P
    Respir Care; 2013 Nov; 58(11):1878-85. PubMed ID: 23674812
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance evaluation of six heat and moisture exchangers according to the Draft International Standard (ISO/DIS 9360).
    Eckerbom B; Lindholm CE
    Acta Anaesthesiol Scand; 1990 Jul; 34(5):404-9. PubMed ID: 2389657
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Understanding and predicting the performance of passive heat and moisture exchangers using a numerical model.
    Leemans M; van Alphen MJA; Vallenduuk W; Dirven R; van den Brekel MWM; Muller SH
    Head Neck; 2023 Apr; 45(4):993-1005. PubMed ID: 36811302
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An efficiency comparison of four heat and moisture exchangers used in the laryngectomized patient.
    Grolman W; Blom ED; Branson RD; Schouwenburg PF; Hamaker RC
    Laryngoscope; 1997 Jun; 107(6):814-20. PubMed ID: 9185739
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An experimental set-up to test heat-moisture exchangers.
    Unal N; Pompe JC; Holland WP; Gültuna I; Huygen PE; Jabaaij K; Ince C; Saygin B; Bruining HA
    Intensive Care Med; 1995 Feb; 21(2):142-8. PubMed ID: 7775695
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of nine heat and moisture exchangers for intraoperative airway heat conservation.
    Tsubota K; Harada J; Goto Y
    J Aerosol Med; 1991; 4(2):117-25. PubMed ID: 10147688
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Comparative clinical evaluation of 4 heat and moisture exchangers (HME) in general anesthesia].
    Cornaggia G; Chidini G; Stella L
    Minerva Anestesiol; 1994 Nov; 60(11):649-55. PubMed ID: 7761013
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Heat and moisture exchangers. Structure and function.
    Wilkes AR
    Respir Care Clin N Am; 1998 Jun; 4(2):261-79. PubMed ID: 9648186
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of tracheal temperature and humidity in laryngectomized individuals and the influence of a heat and moisture exchanger on tracheal climate.
    Zuur JK; Muller SH; Vincent A; Sinaasappel M; de Jongh FH; Hilgers FJ
    Head Neck; 2008 Aug; 30(8):1072-82. PubMed ID: 18528903
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min.
    Martin C; Thomachot L; Quinio B; Viviand X; Albanese J
    Chest; 1995 May; 107(5):1411-5. PubMed ID: 7750340
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation.
    Thomachot L; Boisson C; Arnaud S; Michelet P; Cambon S; Martin C
    Crit Care Med; 2000 Mar; 28(3):714-20. PubMed ID: 10752820
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A novel method of evaluation of three heat-moisture exchangers in six different ventilator settings.
    Unal N; Kanhai JK; Buijk SL; Pompe JC; Holland WP; Gültuna I; Ince C; Saygin B; Bruining HA
    Intensive Care Med; 1998 Feb; 24(2):138-46. PubMed ID: 9539071
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A method of testing the compliance of 15 and 22 mm conical connectors on heat and moisture exchangers to ISO 5356-1:1987.
    Wilkes AR; Hampson MA; Mecklenburgh JS
    J Med Eng Technol; 1997; 21(3-4):147-50. PubMed ID: 9222957
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the efficiency of heat and moisture exchangers during paediatric anaesthesia.
    Luchetti M; Pigna A; Gentili A; Marraro G
    Paediatr Anaesth; 1999; 9(1):39-45. PubMed ID: 10712714
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Heat and moisture exchange devices: are they doing what they are supposed to do?
    Lemmens HJM; Brock-Utne JG
    Anesth Analg; 2004 Feb; 98(2):382-385. PubMed ID: 14742374
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of Heat and Moisture Exchangers and Exhaled Humidity on Aerosol Deposition in a Simulated Ventilator-Dependent Adult Lung Model.
    Ari A; Alwadeai KS; Fink JB
    Respir Care; 2017 May; 62(5):538-543. PubMed ID: 28270542
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A novel, simplified ex vivo method for measuring water exchange performance of heat and moisture exchangers for tracheostomy application.
    van den Boer C; Muller SH; Vincent AD; Züchner K; van den Brekel MW; Hilgers FJ
    Respir Care; 2013 Sep; 58(9):1449-58. PubMed ID: 23481438
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Laboratory evaluation of 10 heat and moisture exchangers using simulated aeromedical evacuation conditions.
    Suliman HS; Fecura SE; Baskin J; Kalns JE
    Mil Med; 2011 Jun; 176(6):656-9. PubMed ID: 21702383
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers.
    Lellouche F; Qader S; Taillé S; Lyazidi A; Brochard L
    Respir Care; 2014 May; 59(5):637-43. PubMed ID: 24106325
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.