119 related articles for article (PubMed ID: 23437820)
1. A rare cause of sensing integrity count in a patient with ICD and dedicated true bipolar lead. Erdogan O; Ozben B Pacing Clin Electrophysiol; 2013 Oct; 36(10):1301-5. PubMed ID: 23437820 [No Abstract] [Full Text] [Related]
2. Re: a rare cause of sensing integrity count in a patient with ICD and dedicated true bipolar lead. Cay S Pacing Clin Electrophysiol; 2013 Jul; 36(7):921. PubMed ID: 23663208 [No Abstract] [Full Text] [Related]
3. ICD shocks in a Brugada syndrome patient: what is the mechanism? Sacher F; Field ME; Laborderie J; Reuter S; Haissaguerre M; Clementy J J Cardiovasc Electrophysiol; 2007 Aug; 18(8):886-8. PubMed ID: 17506856 [No Abstract] [Full Text] [Related]
4. Near-Fatal ICD Lead Dysfunction with Implications for ICD Testing. Wutzler A; Attanasio P; Haverkamp W; Blaschke F Pacing Clin Electrophysiol; 2016 Jan; 39(1):105-6. PubMed ID: 26519249 [TBL] [Abstract][Full Text] [Related]
5. Electrocautery-induced ventricular fibrillation during routine implantable cardioverter-defibrillator generator replacement. Cassagneau R; Hanninen M; Yee R Europace; 2014 Mar; 16(3):319. PubMed ID: 24068449 [No Abstract] [Full Text] [Related]
7. Atrial tracking with a single ICD lead in the ventricle. Spears D; Selvaraj R; Dhopeswarkar R; Nanthakumar K J Cardiovasc Electrophysiol; 2008 Apr; 19(4):440-1. PubMed ID: 18298516 [No Abstract] [Full Text] [Related]
8. Hyperkalemia induced T wave oversensing leading to loss of biventricular pacing and inappropriate ICD shocks. Koul AK; Keller S; Clancy JF; Lampert R; Batsford WP; Rosenfeld LE Pacing Clin Electrophysiol; 2004 May; 27(5):681-3. PubMed ID: 15125731 [TBL] [Abstract][Full Text] [Related]
9. Ventricular arrhythmias in patients with implanted cardioverter defibrillators. John RM; Stevenson WG Trends Cardiovasc Med; 2012 Oct; 22(7):169-73. PubMed ID: 22902094 [TBL] [Abstract][Full Text] [Related]
10. Multiple inappropriate defibrillator discharges due to Twiddler's syndrome. Asbach S; Brunner M; Zehender M; Bode C; Faber TS Wien Klin Wochenschr; 2005 Dec; 117(23-24):801. PubMed ID: 16437315 [No Abstract] [Full Text] [Related]
11. Twisting until it breaks: a rare cause of ICD lead failure. Budzikowski AS; Uyguanco E; Gunsburg MY; Kassotis J Cardiol J; 2008; 15(6):558-60. PubMed ID: 19039762 [TBL] [Abstract][Full Text] [Related]
13. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years. Kleemann T; Becker T; Doenges K; Vater M; Senges J; Schneider S; Saggau W; Weisse U; Seidl K Circulation; 2007 May; 115(19):2474-80. PubMed ID: 17470696 [TBL] [Abstract][Full Text] [Related]
14. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture. Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874 [TBL] [Abstract][Full Text] [Related]
15. T-wave oversensing is more dependent on ICD sensitivity algorithm than lead sensing configuration. Punjabi AH; Dermovsesian A; Karnik AA J Electrocardiol; 2018; 51(4):734-737. PubMed ID: 29997023 [TBL] [Abstract][Full Text] [Related]
16. Short-long-short sequence caused by ventricular safety pacing inducing ventricular tachycardia in a patient with a dual-chamber implantable cardioverter defibrillator. Hayashi M; Takatsuki S; Messali A; Milliez P; Extramiana F; Leenhardt A Europace; 2008 Oct; 10(10):1238-42. PubMed ID: 18617506 [TBL] [Abstract][Full Text] [Related]
17. Undersensing of ventricular fibrillation due to interference between a pacemaker and defibrillator in the same patient. Van Casteren L; Huybrechts W; Willems R Europace; 2009 Oct; 11(10):1390-1. PubMed ID: 19654130 [TBL] [Abstract][Full Text] [Related]
18. Inappropriate ICD discharges due to noise oversensing as the first sign of repetitive perforations of the right ventricular lead. Ueda-Tatsumoto A; Fukamizu S; Nishizaki M; Sakurada H; Hiraoka M Pacing Clin Electrophysiol; 2009 Nov; 32(11):1481-4. PubMed ID: 19712072 [TBL] [Abstract][Full Text] [Related]
19. [Efficacy and safety of implantable cardioverter defibrillator avoiding routine defibrillation threshold testing]. Liu Q; Zhou S; Qi S; Zeng G; Ma X; Huang H Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2009 Nov; 34(11):1132-5. PubMed ID: 19952404 [TBL] [Abstract][Full Text] [Related]
20. Suppression of cautery-induced electromagnetic interference of cardiac implantable electrical devices by closely spaced bipolar sensing. Suresh M; Benditt DG; Gold B; Joshi GP; Lurie KG Anesth Analg; 2011 Jun; 112(6):1358-61. PubMed ID: 21543788 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]