146 related articles for article (PubMed ID: 23440071)
1. Lab-on-DVD: standard DVD drives as a novel laser scanning microscope for image based point of care diagnostics.
Ramachandraiah H; Amasia M; Cole J; Sheard P; Pickhaver S; Walker C; Wirta V; Lexow P; Lione R; Russom A
Lab Chip; 2013 Apr; 13(8):1578-85. PubMed ID: 23440071
[TBL] [Abstract][Full Text] [Related]
2. Rapid, low-cost and instrument-free CD4+ cell counting for HIV diagnostics in resource-poor settings.
Glynn MT; Kinahan DJ; Ducrée J
Lab Chip; 2014 Aug; 14(15):2844-51. PubMed ID: 24911165
[TBL] [Abstract][Full Text] [Related]
3. Microfluidic CD4+ T-cell counting device using chemiluminescence-based detection.
Wang Z; Chin SY; Chin CD; Sarik J; Harper M; Justman J; Sia SK
Anal Chem; 2010 Jan; 82(1):36-40. PubMed ID: 19938816
[TBL] [Abstract][Full Text] [Related]
4. Microfluidic CD4+ and CD8+ T lymphocyte counters for point-of-care HIV diagnostics using whole blood.
Watkins NN; Hassan U; Damhorst G; Ni H; Vaid A; Rodriguez W; Bashir R
Sci Transl Med; 2013 Dec; 5(214):214ra170. PubMed ID: 24307694
[TBL] [Abstract][Full Text] [Related]
5. A quartz nanopillar hemocytometer for high-yield separation and counting of CD4(+) T lymphocytes.
Kim DJ; Seol JK; Wu Y; Ji S; Kim GS; Hyung JH; Lee SY; Lim H; Fan R; Lee SK
Nanoscale; 2012 Apr; 4(7):2500-7. PubMed ID: 22218701
[TBL] [Abstract][Full Text] [Related]
6. On-chip sample preparation by controlled release of antibodies for simple CD4 counting.
Beck M; Brockhuis S; van der Velde N; Breukers C; Greve J; Terstappen LW
Lab Chip; 2012 Jan; 12(1):167-73. PubMed ID: 22048158
[TBL] [Abstract][Full Text] [Related]
7. Magnetic bead based immunoassay for enumeration of CD4+ T lymphocytes on a microfluidic device.
Gao D; Li HF; Guo GS; Lin JM
Talanta; 2010 Jul; 82(2):528-33. PubMed ID: 20602931
[TBL] [Abstract][Full Text] [Related]
8. Highly-integrated lab-on-chip system for point-of-care multiparameter analysis.
Schumacher S; Nestler J; Otto T; Wegener M; Ehrentreich-Förster E; Michel D; Wunderlich K; Palzer S; Sohn K; Weber A; Burgard M; Grzesiak A; Teichert A; Brandenburg A; Koger B; Albers J; Nebling E; Bier FF
Lab Chip; 2012 Feb; 12(3):464-73. PubMed ID: 22038328
[TBL] [Abstract][Full Text] [Related]
9. CD4+ T lymphocytes enumeration by an easy-to-use single platform image cytometer for HIV monitoring in resource-constrained settings.
Li X; Ymeti A; Lunter B; Breukers C; Tibbe AG; Terstappen LW; Greve J
Cytometry B Clin Cytom; 2007 Sep; 72(5):397-407. PubMed ID: 17311352
[TBL] [Abstract][Full Text] [Related]
10. Coincidence detection of heterogeneous cell populations from whole blood with coplanar electrodes in a microfluidic impedance cytometer.
Hassan U; Bashir R
Lab Chip; 2014 Nov; 14(22):4370-81. PubMed ID: 25231594
[TBL] [Abstract][Full Text] [Related]
11. A microchip CD4 counting method for HIV monitoring in resource-poor settings.
Rodriguez WR; Christodoulides N; Floriano PN; Graham S; Mohanty S; Dixon M; Hsiang M; Peter T; Zavahir S; Thior I; Romanovicz D; Bernard B; Goodey AP; Walker BD; McDevitt JT
PLoS Med; 2005 Jul; 2(7):e182. PubMed ID: 16013921
[TBL] [Abstract][Full Text] [Related]
12. Commercialization of microfluidic point-of-care diagnostic devices.
Chin CD; Linder V; Sia SK
Lab Chip; 2012 Jun; 12(12):2118-34. PubMed ID: 22344520
[TBL] [Abstract][Full Text] [Related]
13. Integrating microfluidics and lensless imaging for point-of-care testing.
Moon S; Keles HO; Ozcan A; Khademhosseini A; Haeggstrom E; Kuritzkes D; Demirci U
Biosens Bioelectron; 2009 Jul; 24(11):3208-14. PubMed ID: 19467854
[TBL] [Abstract][Full Text] [Related]
14. Microsieve lab-chip device for rapid enumeration and fluorescence in situ hybridization of circulating tumor cells.
Lim LS; Hu M; Huang MC; Cheong WC; Gan AT; Looi XL; Leong SM; Koay ES; Li MH
Lab Chip; 2012 Nov; 12(21):4388-96. PubMed ID: 22930096
[TBL] [Abstract][Full Text] [Related]
15. Lensless imaging for point-of-care testing.
Moon S; Keles HO; Kim YG; Kuritzkes D; Demirci U
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():6376-9. PubMed ID: 19964416
[TBL] [Abstract][Full Text] [Related]
16. A microfluidic device for practical label-free CD4(+) T cell counting of HIV-infected subjects.
Cheng X; Irimia D; Dixon M; Sekine K; Demirci U; Zamir L; Tompkins RG; Rodriguez W; Toner M
Lab Chip; 2007 Feb; 7(2):170-8. PubMed ID: 17268618
[TBL] [Abstract][Full Text] [Related]
17. Enhancing the performance of a point-of-care CD4+ T-cell counting microchip through monocyte depletion for HIV/AIDS diagnostics.
Cheng X; Gupta A; Chen C; Tompkins RG; Rodriguez W; Toner M
Lab Chip; 2009 May; 9(10):1357-64. PubMed ID: 19417901
[TBL] [Abstract][Full Text] [Related]
18. All-printed cell counting chambers with on-chip sample preparation for point-of-care CD4 counting.
Wasserberg D; Zhang X; Breukers C; Connell BJ; Baeten E; van den Blink D; S O L À Benet È; Bloem AC; Nijhuis M; Wensing AMJ; Terstappen LWMM; Beck M
Biosens Bioelectron; 2018 Oct; 117():659-668. PubMed ID: 30005387
[TBL] [Abstract][Full Text] [Related]
19. On-chip counting the number and the percentage of CD4+ T lymphocytes.
Wang YN; Kang Y; Xu D; Chon CH; Barnett L; Kalams SA; Li D; Li D
Lab Chip; 2008 Feb; 8(2):309-15. PubMed ID: 18231671
[TBL] [Abstract][Full Text] [Related]
20. Rapid automated cell quantification on HIV microfluidic devices.
Alyassin MA; Moon S; Keles HO; Manzur F; Lin RL; Hæggstrom E; Kuritzkes DR; Demirci U
Lab Chip; 2009 Dec; 9(23):3364-9. PubMed ID: 19904402
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]