BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

502 related articles for article (PubMed ID: 23440636)

  • 1. Acquisition parameters optimization of a transmission electron forward scatter diffraction system in a cold-field emission scanning electron microscope for nanomaterials characterization.
    Brodusch N; Demers H; Trudeau M; Gauvin R
    Scanning; 2013; 35(6):375-86. PubMed ID: 23440636
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel approach for site-specific atom probe specimen preparation by focused ion beam and transmission electron backscatter diffraction.
    Babinsky K; De Kloe R; Clemens H; Primig S
    Ultramicroscopy; 2014 Sep; 144():9-18. PubMed ID: 24815026
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Nanometres-resolution Kikuchi patterns from materials science specimens with transmission electron forward scatter diffraction in the scanning electron microscope.
    Brodusch N; Demers H; Gauvin R
    J Microsc; 2013 Apr; 250(1):1-14. PubMed ID: 23346885
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transmission Kikuchi diffraction versus electron back-scattering diffraction: A case study on an electron transparent cross-section of TWIP steel.
    Gazder AA; Elkhodary KI; Nancarrow MJB; Saleh AA
    Micron; 2017 Dec; 103():53-63. PubMed ID: 28972922
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Using transmission Kikuchi diffraction to study intergranular stress corrosion cracking in type 316 stainless steels.
    Meisnar M; Vilalta-Clemente A; Gholinia A; Moody M; Wilkinson AJ; Huin N; Lozano-Perez S
    Micron; 2015 Aug; 75():1-10. PubMed ID: 25974882
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Beam broadening in transmission and conventional EBSD.
    Rice KP; Chen Y; Keller RR; Stoykovich MP
    Micron; 2017 Apr; 95():42-50. PubMed ID: 28192763
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transmission Kikuchi diffraction: The impact of the signal-to-noise ratio.
    Tokarski T; Nolze G; Winkelmann A; Rychłowski Ł; Bała P; Cios G
    Ultramicroscopy; 2021 Nov; 230():113372. PubMed ID: 34479040
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Energy-weighted dynamical scattering simulations of electron diffraction modalities in the scanning electron microscope.
    Pascal E; Singh S; Callahan PG; Hourahine B; Trager-Cowan C; Graef M
    Ultramicroscopy; 2018 Apr; 187():98-106. PubMed ID: 29428431
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of Ultra-fine Grained and Nanocrystalline Materials Using Transmission Kikuchi Diffraction.
    Proust G; Trimby P; Piazolo S; Retraint D
    J Vis Exp; 2017 Apr; (122):. PubMed ID: 28447998
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Orientation mapping of nanostructured materials using transmission Kikuchi diffraction in the scanning electron microscope.
    Trimby PW
    Ultramicroscopy; 2012 Sep; 120():16-24. PubMed ID: 22796555
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electron imaging with an EBSD detector.
    Wright SI; Nowell MM; de Kloe R; Camus P; Rampton T
    Ultramicroscopy; 2015 Jan; 148():132-145. PubMed ID: 25461590
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diffraction contrast dependence on sample thickness and incident energy in on-axis Transmission Kikuchi Diffraction in SEM.
    Brodu E; Bouzy E; Fundenberger JJ
    Ultramicroscopy; 2017 Oct; 181():123-133. PubMed ID: 28551504
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A study on the indexing method of the electron backscatter diffraction pattern assisted by the Kikuchi bandwidth.
    Peng F; Zhang Y; Zhang J; Lin C; Jiang C; Miao H; Zeng Y
    J Microsc; 2020 Jan; 277(1):3-11. PubMed ID: 31863464
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of accelerating voltage and specimen thickness on the spatial resolution of transmission electron backscatter diffraction in Cu.
    Shih JW; Kuo KW; Kuo JC; Kuo TY
    Ultramicroscopy; 2017 Jun; 177():43-52. PubMed ID: 28284057
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of the microstructure of bulk MgB
    Koblischka-Veneva A; Koblischka MR; Schmauch J; Noudem J; Murakami M
    J Microsc; 2019 Jun; 274(3):123-131. PubMed ID: 30852839
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Practical application of direct electron detectors to EBSD mapping in 2D and 3D.
    Mingard KP; Stewart M; Gee MG; Vespucci S; Trager-Cowan C
    Ultramicroscopy; 2018 Jan; 184(Pt A):242-251. PubMed ID: 28992558
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of microscope parameter and specimen thickness of spatial resolution of transmission electron backscatter diffraction.
    Wang YZ; Kong MG; Liu ZW; Lin CC; Zeng Y
    J Microsc; 2016 Oct; 264(1):34-40. PubMed ID: 27086586
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High throughput crystal structure and composition mapping of crystalline nanoprecipitates in alloys by transmission Kikuchi diffraction and analytical electron microscopy.
    Bhattacharya A; Parish CM; Henry J; Katoh Y
    Ultramicroscopy; 2019 Jul; 202():33-43. PubMed ID: 30933741
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of Orientation Mapping in SEM and TEM.
    Sugar JD; McKeown JT; Banga D; Michael JR
    Microsc Microanal; 2020 Aug; 26(4):630-640. PubMed ID: 32583757
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dark-field imaging based on post-processed electron backscatter diffraction patterns of bulk crystalline materials in a scanning electron microscope.
    Brodusch N; Demers H; Gauvin R
    Ultramicroscopy; 2015 Jan; 148():123-131. PubMed ID: 25461589
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 26.