These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up. Poerner TC; Otto S; Gassdorf J; Nitsche K; Janiak F; Scheller B; Goebel B; Jung C; Figulla HR Circ Cardiovasc Interv; 2014 Dec; 7(6):760-7. PubMed ID: 25371536 [TBL] [Abstract][Full Text] [Related]
4. Comparison of long-term in-stent vascular response between abluminal groove-filled biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent: 3-year OCT follow-up from the TARGET I trial. Xu B; Zhang YJ; Sun ZW; Qiao SB; Chen SL; Zhang RY; Pan DR; Pang S; Zhang Q; Xu L; Yang YJ; Leon MB; Gao RL Int J Cardiovasc Imaging; 2015 Dec; 31(8):1489-96. PubMed ID: 26208685 [TBL] [Abstract][Full Text] [Related]
5. Comparison of zotarolimus-eluting stent and everolimus-eluting stent for vascular healing response: serial 3-month and 12-month optical coherence tomography study. Kim SJ; Lee H; Cho JM; Park CB; Kim W; Kato K; Yonetsu T; Kim CJ; Jang IK Coron Artery Dis; 2013 Aug; 24(5):431-9. PubMed ID: 23722649 [TBL] [Abstract][Full Text] [Related]
6. Serial assessment of vessel interactions after drug-eluting stent implantation in unprotected distal left main coronary artery disease using frequency-domain optical coherence tomography. Fujino Y; Attizzani GF; Bezerra HG; Wang W; Tahara S; Yamamoto H; Chamie D; Kanaya T; Mehanna E; Takagi K; Nakamura S; Costa MA JACC Cardiovasc Interv; 2013 Oct; 6(10):1035-45. PubMed ID: 24156964 [TBL] [Abstract][Full Text] [Related]
7. Comparison of neointimal coverage between durable-polymer everolimus-eluting stents and bioresorbable-polymer everolimus-eluting stents 1 year after implantation using high-resolution coronary angioscopy. Nojima Y; Adachi H; Ihara M; Kurimoto T; Okayama K; Sakata Y; Nanto S Catheter Cardiovasc Interv; 2019 Aug; 94(2):204-209. PubMed ID: 30737973 [TBL] [Abstract][Full Text] [Related]
8. Comparison of a novel biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: results of the randomized BIOFLOW-II trial. Windecker S; Haude M; Neumann FJ; Stangl K; Witzenbichler B; Slagboom T; Sabaté M; Goicolea J; Barragan P; Cook S; Piot C; Richardt G; Merkely B; Schneider H; Bilger J; Erne P; Waksman R; Zaugg S; Jüni P; Lefèvre T Circ Cardiovasc Interv; 2015 Feb; 8(2):e001441. PubMed ID: 25634905 [TBL] [Abstract][Full Text] [Related]
9. The REMEDEE-OCT Study: An Evaluation of the Bioengineered COMBO Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent Compared With a Cobalt-Chromium Everolimus-Eluting Stent in Patients With Acute Coronary Syndromes: Insights From Optical Coherence Tomography Imaging Analysis. Jaguszewski M; Aloysius R; Wang W; Bezerra HG; Hill J; De Winter RJ; Karjalainen PP; Verheye S; Wijns W; Lüscher TF; Joner M; Costa M; Landmesser U JACC Cardiovasc Interv; 2017 Mar; 10(5):489-499. PubMed ID: 28279316 [TBL] [Abstract][Full Text] [Related]
10. Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography. Ohtani H; Kimura S; Sugiyama T; Hishikari K; Misawa T; Mizusawa M; Hayasaka K; Yamakami Y; Kojima K; Sagawa Y; Hikita H; Ashikaga T; Takahashi A; Isobe M Int J Cardiovasc Imaging; 2017 Feb; 33(2):177-186. PubMed ID: 27761750 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of Early Healing Profile and Neointimal Transformation Over 24 Months Using Longitudinal Sequential Optical Coherence Tomography Assessments and 3-Year Clinical Results of the New Dual-Therapy Endothelial Progenitor Cell Capturing Sirolimus-Eluting Combo Stent: The EGO-Combo Study. Lee SW; Lam SC; Tam FC; Chan KK; Shea CP; Kong SL; Wong AY; Yung A; Zhang LW; Tse HF; Wu KK; Chan R; Haude M; Mehran R; Mintz GS; Maehara A Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27418609 [TBL] [Abstract][Full Text] [Related]
12. Early vascular healing with rapid breakdown biodegradable polymer sirolimus-eluting versus durable polymer everolimus-eluting stents assessed by optical coherence tomography. Tada T; Byrne RA; Schuster T; Cuni R; Kitabata H; Tiroch K; Dirninger A; Gratze F; Kaspar K; Zenker G; Joner M; Schömig A; Kastrati A Cardiovasc Revasc Med; 2013; 14(2):84-9. PubMed ID: 23352095 [TBL] [Abstract][Full Text] [Related]
13. Overtime evaluation of the vascular HEALing process after everolimus-eluting stent implantation by optical coherence tomography. The HEAL-EES study. Otsuki S; Brugaletta S; Sabaté M; Shiratori Y; Gomez-Monterrosas O; Scalone G; Romero-Villafañe S; Hernández-Enríquez M; Freixa X; Martín-Yuste V; Masotti M Cardiovasc Revasc Med; 2016 Jun; 17(4):241-7. PubMed ID: 27158001 [TBL] [Abstract][Full Text] [Related]
14. A clinical and angiographic study of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with multivessel coronary artery disease: the EXECUTIVE trial (EXecutive RCT: evaluating XIENCE V in a multi vessel disease). Ribichini F; Romano M; Rosiello R; La Vecchia L; Cabianca E; Caramanno G; Milazzo D; Loschiavo P; Rigattieri S; Musarò S; Pironi B; Fiscella A; Amico F; Indolfi C; Spaccarotella C; Bartorelli A; Trabattoni D; Della Rovere F; Rolandi A; Beqaraj F; Belli R; Sangiorgio P; Villani R; Berni A; Sheiban I; Lopera Quijada MJ; Cappi B; Ribaldi L; Vassanelli C; JACC Cardiovasc Interv; 2013 Oct; 6(10):1012-22. PubMed ID: 24055444 [TBL] [Abstract][Full Text] [Related]
15. Two-week interval optical coherence tomography: imaging evidence on neointimal coverage completion after implantation of the Endeavor zotarolimus-eluting stent. Nishinari M; Shimohama T; Tojo T; Shiono T; Shinagawa H; Kameda R; Aoyama N; Izumi T Catheter Cardiovasc Interv; 2013 Dec; 82(7):E871-8. PubMed ID: 23873677 [TBL] [Abstract][Full Text] [Related]
16. Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial. Kuramitsu S; Kazuno Y; Sonoda S; Domei T; Jinnouchi H; Yamaji K; Soga Y; Shirai S; Ando K; Saito S Eur Heart J Cardiovasc Imaging; 2016 Jan; 17(1):34-40. PubMed ID: 26333375 [TBL] [Abstract][Full Text] [Related]
17. Quantitative and qualitative changes in DES-related neointimal tissue based on serial OCT. Kim JS; Hong MK; Shin DH; Kim BK; Ko YG; Choi D; Jang Y JACC Cardiovasc Imaging; 2012 Nov; 5(11):1147-55. PubMed ID: 23153915 [TBL] [Abstract][Full Text] [Related]
18. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries). Ormiston J; Webster M; Stewart J; Vrolix M; Whitbourn R; Donohoe D; Knape C; Lansky A; Attizzani GF; Fitzgerald P; Kandzari DE; Wijns W JACC Cardiovasc Interv; 2013 Oct; 6(10):1026-34. PubMed ID: 24055443 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography. Li S; Gai L; Yang T; Zhang L; Xu X; Bai Q; Xu H; Wang Y Catheter Cardiovasc Interv; 2013 Apr; 81(5):768-75. PubMed ID: 22639418 [TBL] [Abstract][Full Text] [Related]
20. First-in-man study evaluating the safety and efficacy of a second generation biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo coronary lesions: clinical, Angiographic, and OCT outcomes of CREDIT-1. Wang G; Sun Z; Jin Q; Xu K; Li Y; Wang X; Ma Y; Liu H; Zhao X; Wang B; Deng J; Guan S; Ge M; Wang X; Xu B; Han Y Catheter Cardiovasc Interv; 2015 Mar; 85 Suppl 1():744-51. PubMed ID: 25630447 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]