  • 1. CareFusion 3100A and 3100B high-frequency oscillatory ventilator breathing circuit component may be defective and not hold pressure.
    Health Devices; 2012 Nov; 41(11):371. PubMed ID: 23444732
    [No Abstract]   [Full Text] [Related]  

  • 2. CareFusion 3100B high-frequency oscillatory ventilator diaphragms require pre-use inspection.
    Health Devices; 2011 Aug; 40(8):263-4. PubMed ID: 23444532
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro performance comparison of the Sensormedics 3100A and B high-frequency oscillatory ventilators.
    Custer JW; Ahmed A; Kaczka DW; Mulreany DG; Hager DN; Simon BA; Easley RB
    Pediatr Crit Care Med; 2011 Jul; 12(4):e176-80. PubMed ID: 21037502
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Unloading work of breathing during high-frequency oscillatory ventilation: a bench study.
    van Heerde M; Roubik K; Kopelent V; Plötz FB; Markhorst DG
    Crit Care; 2006; 10(4):R103. PubMed ID: 16848915
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design and control of a demand flow system assuring spontaneous breathing of a patient connected to an HFO ventilator.
    Roubík K; Ráfl J; van Heerde M; Markhorst DG
    IEEE Trans Biomed Eng; 2011 Nov; 58(11):3225-33. PubMed ID: 21859597
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Bunnell Life Pulse high-frequency ventilator heated wire breathing circuit may overheat and melt.
    Health Devices; 2013 Apr; 42(4):137-8. PubMed ID: 23687676
    [No Abstract]   [Full Text] [Related]  

  • 7. Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome.
    Hager DN; Fessler HE; Kaczka DW; Shanholtz CB; Fuld MK; Simon BA; Brower RG
    Crit Care Med; 2007 Jun; 35(6):1522-9. PubMed ID: 17440422
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Carbon dioxide elimination and gas displacement vary with piston position during high-frequency oscillatory ventilation.
    Hamel DS; Katz AL; Craig DM; Davies JD; Cheifetz IM
    Respir Care; 2005 Mar; 50(3):361-6. PubMed ID: 15737246
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lung-protective higher frequency oscillatory ventilation.
    Derdak S
    Crit Care Med; 2008 Apr; 36(4):1358-60. PubMed ID: 18379266
    [No Abstract]   [Full Text] [Related]  

  • 10. Determinants of airleak flow during humming V high-frequency oscillatory ventilation in an open-compartment ex-vivo model of airleak.
    Liu TY; Lien SH; Hua YM; Soong WJ; Lu P; Yuh YS
    Pediatr Pulmonol; 2007 Dec; 42(12):1104-9. PubMed ID: 17955549
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Demand flow facilitates spontaneous breathing during high-frequency oscillatory ventilation in a pig model.
    van Heerde M; Roubik K; Kopelent V; Plötz FB; Markhorst DG
    Crit Care Med; 2009 Mar; 37(3):1068-73. PubMed ID: 19237919
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Max airway pressure alarm will not limit airway pressure in CareFusion 3100A high-frequency oscillatory ventilators.
    Health Devices; 2013 Jul; 42(7):233. PubMed ID: 23967473
    [No Abstract]   [Full Text] [Related]  

  • 13. Comparison of two ventilator circuits for Dräger Babylog high-frequency ventilation.
    Wheeler KI; Moore GP; Morley CJ; Davis PG
    J Paediatr Child Health; 2011 Apr; 47(4):211-6. PubMed ID: 21244551
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Humidification during high-frequency oscillation ventilation is affected by ventilator circuit and ventilatory setting.
    Chikata Y; Imanaka H; Onishi Y; Ueta M; Nishimura M
    Paediatr Anaesth; 2009 Aug; 19(8):779-83. PubMed ID: 19624365
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of a new circuit configuration for the VDR-4 high-frequency percussive ventilator.
    Jones SW; Short KA; Hanson WJ; Hendrix L; Charles AG; Cairns BA
    J Burn Care Res; 2010; 31(4):640-5. PubMed ID: 20616653
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Provo multicenter early high-frequency oscillatory ventilation trial: improved pulmonary and clinical outcome in respiratory distress syndrome.
    Gerstmann DR; Minton SD; Stoddard RA; Meredith KS; Monaco F; Bertrand JM; Battisti O; Langhendries JP; Francois A; Clark RH
    Pediatrics; 1996 Dec; 98(6 Pt 1):1044-57. PubMed ID: 8951252
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prospective, randomized comparison of high-frequency oscillatory ventilation and conventional mechanical ventilation in pediatric respiratory failure.
    Arnold JH; Hanson JH; Toro-Figuero LO; Gutiérrez J; Berens RJ; Anglin DL
    Crit Care Med; 1994 Oct; 22(10):1530-9. PubMed ID: 7924362
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of the Sensormedics 3100A and Bronchotron transporter in a neonatal piglet ARDS model.
    Messier SE; Digeronimo RJ; Gillette RK
    Pediatr Pulmonol; 2009 Jul; 44(7):693-700. PubMed ID: 19499589
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Four methods of measuring tidal volume during high-frequency oscillatory ventilation.
    Hager DN; Fuld M; Kaczka DW; Fessler HE; Brower RG; Simon BA
    Crit Care Med; 2006 Mar; 34(3):751-7. PubMed ID: 16505661
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A review of high frequency oscillation ventilation in the neonate.
    Wheeler HJ; Nokes LD; Powell T
    J Med Eng Technol; 2007; 31(5):367-74. PubMed ID: 17701782
    [TBL] [Abstract][Full Text] [Related]  