  • 1. Diagnosis of high-voltage conductor fractures in Sprint Fidelis leads.
    Koneru JN; Gunderson BD; Sachanandani H; Wohl BN; Kendall KT; Swerdlow CD; Ellenbogen KA
    Heart Rhythm; 2013 Jun; 10(6):813-8. PubMed ID: 23454808
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead.
    Kallinen LM; Hauser RG; Lee KW; Almquist AK; Katsiyiannis WT; Tang CY; Melby DP; Gornick CC
    Heart Rhythm; 2008 Jun; 5(6):775-9. PubMed ID: 18534361
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures.
    Kallinen LM; Hauser RG; Tang C; Melby DP; Almquist AK; Katsiyiannis WT; Gornick CC
    Heart Rhythm; 2010 Aug; 7(8):1048-55. PubMed ID: 20493965
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Lead electrical parameters may not predict integrity of the Sprint Fidelis ICD lead.
    Maytin M; Epstein LM
    Heart Rhythm; 2012 Sep; 9(9):1446-51. PubMed ID: 22537883
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead.
    Hauser RG; Kallinen LM; Almquist AK; Gornick CC; Katsiyiannis WT
    Heart Rhythm; 2007 Jul; 4(7):892-6. PubMed ID: 17599673
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance of Lead Integrity Alert to assist in the clinical diagnosis of implantable cardioverter defibrillator lead failures: analysis of different implantable cardioverter defibrillator leads.
    Ellenbogen KA; Gunderson BD; Stromberg KD; Swerdlow CD
    Circ Arrhythm Electrophysiol; 2013 Dec; 6(6):1169-77. PubMed ID: 24099976
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Sprint Fidelis implantable cardioverter-defibrillator (ICD) leads (Medtronic, Inc., Minneapolis, MN, USA) were removed from the market in October 2007 because of the rate of pace-sense conductor fractures.
    Arias MA; Puchol A; Castellanos E; Pachón M
    Heart Rhythm; 2009 Jan; 6(1):e6-7; author reply e7. PubMed ID: 19121790
    [No Abstract]   [Full Text] [Related]  

  • 8. Internal insulation breaches in an implantable cardioverter-defibrillator lead with redundant conductors.
    Hauser RG; Sengupta J; Schloss EJ; Stanberry LI; Wananu MK; Abdelhadi R
    Heart Rhythm; 2019 Aug; 16(8):1215-1222. PubMed ID: 30772531
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-term changes in high-voltage impedance of defibrillating leads.
    Val-Mejias JE; Janet DR; Ramadas S
    Pacing Clin Electrophysiol; 2009 Mar; 32 Suppl 1():S151-4. PubMed ID: 19250081
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert.
    Gelder RN; Gunderson BD
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Downloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Stadler RW; Gillberg JM; Patel AS; Ellenbogen KA
    Circulation; 2008 Nov; 118(21):2122-9. PubMed ID: 18981299
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transvenous extraction of implantable cardioverter-defibrillator leads under advisory--a comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads.
    Brunner MP; Cronin EM; Jacob J; Duarte VE; Tarakji KG; Martin DO; Callahan T; Borek PP; Cantillon DJ; Niebauer MJ; Saliba WI; Kanj M; Wazni O; Baranowski B; Wilkoff BL
    Heart Rhythm; 2013 Oct; 10(10):1444-50. PubMed ID: 23816440
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Limitation of programmed alerts to predict ICD lead failures.
    Vlay SC
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):554-5. PubMed ID: 19335870
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Time course of oversensing and impedance changes in developing implantable cardioverter-defibrillator lead fracture.
    Himes A; Hoium S; Swerdlow CD
    Heart Rhythm O2; 2022 Dec; 3(6Part A):688-698. PubMed ID: 36589919
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Very late follow-up of a passive defibrillator lead under recall: do failure rates increase during long-term observation.
    Frey SM; Sticherling C; Kraus R; Ammann P; Kühne M; Osswald S; Schaer B
    Pacing Clin Electrophysiol; 2015 Mar; 38(3):306-10. PubMed ID: 25599764
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure.
    Hauser RG; Hayes DL
    Heart Rhythm; 2009 May; 6(5):605-10. PubMed ID: 19285920
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accelerating risk of Fidelis lead fracture.
    Farwell D; Green MS; Lemery R; Gollob MH; Birnie DH
    Heart Rhythm; 2008 Oct; 5(10):1375-9. PubMed ID: 18783996
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Inappropriate implantable cardioverter defibrillator shocks in fractured Sprint Fidelis leads associated with 'appropriate' interrogation.
    Farwell D; Redpath C; Birnie D; Gollob M; Lemery R; Posan E; Green M
    Europace; 2008 Jun; 10(6):726-8. PubMed ID: 18456645
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Increased rate of subacute lead complications with small-caliber implantable cardioverter-defibrillator leads.
    Ellis CR; Rottman JN
    Heart Rhythm; 2009 May; 6(5):619-24. PubMed ID: 19389648
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Riata implantable cardioverter-defibrillator lead failure: analysis of explanted leads with a unique insulation defect.
    Hauser RG; McGriff D; Retel LK
    Heart Rhythm; 2012 May; 9(5):742-9. PubMed ID: 22209723
    [TBL] [Abstract][Full Text] [Related]  