These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 23455118)

  • 1. Infrared microcalorimetric spectroscopy using quantum cascade lasers.
    Morales-Rodríguez ME; Senesac LR; Rajic S; Lavrik NV; Smith DB; Datskos PG
    Opt Lett; 2013 Feb; 38(4):507-9. PubMed ID: 23455118
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection and differentiation of biological species using microcalorimetric spectroscopy.
    Arakawa ET; Lavrik NV; Rajic S; Datskos PG
    Ultramicroscopy; 2003; 97(1-4):459-65. PubMed ID: 12801702
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Indirect absorption spectroscopy using quantum cascade lasers: mid-infrared refractometry and photothermal spectroscopy.
    Pfeifer M; Ruf A; Fischer P
    Opt Express; 2013 Nov; 21(22):25643-54. PubMed ID: 24216789
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Infrared photothermal imaging spectroscopy for detection of trace explosives on surfaces.
    Kendziora CA; Furstenberg R; Papantonakis M; Nguyen V; Byers J; Andrew McGill R
    Appl Opt; 2015 Nov; 54(31):F129-38. PubMed ID: 26560599
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Infrared absorption nano-spectroscopy using sample photoexpansion induced by tunable quantum cascade lasers.
    Lu F; Belkin MA
    Opt Express; 2011 Oct; 19(21):19942-7. PubMed ID: 21997003
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Nanoscale infrared spectroscopy: improving the spectral range of the photothermal induced resonance technique.
    Katzenmeyer AM; Aksyuk V; Centrone A
    Anal Chem; 2013 Feb; 85(4):1972-9. PubMed ID: 23363013
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Enhancing the Responsivity of Uncooled Infrared Detectors Using Plasmonics for High-Performance Infrared Spectroscopy.
    Ahmed AS; Kim HJ; Kim J; Hwang KS; Kim S
    Sensors (Basel); 2017 Apr; 17(4):. PubMed ID: 28425964
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Standoff pump-probe photothermal detection of hazardous chemicals.
    Sharma RC; Kumar S; Parmar A; Mann M; Prakash S; Thakur SN
    Sci Rep; 2020 Sep; 10(1):15053. PubMed ID: 32929139
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Infrared spectroscopic analysis of human interstitial fluid in vitro and in vivo using FT-IR spectroscopy and pulsed quantum cascade lasers (QCL): Establishing a new approach to non invasive glucose measurement.
    Pleitez M; von Lilienfeld-Toal H; Mäntele W
    Spectrochim Acta A Mol Biomol Spectrosc; 2012 Jan; 85(1):61-5. PubMed ID: 22000639
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Photothermal infrared spectroscopy of airborne samples with mechanical string resonators.
    Yamada S; Schmid S; Larsen T; Hansen O; Boisen A
    Anal Chem; 2013 Nov; 85(21):10531-5. PubMed ID: 24083320
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Broadband spectroscopy with external cavity quantum cascade lasers beyond conventional absorption measurements.
    Lambrecht A; Pfeifer M; Konz W; Herbst J; Axtmann F
    Analyst; 2014 May; 139(9):2070-8. PubMed ID: 24367797
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Vibrational spectroscopy of bare and solvated ionic complexes of biological relevance.
    Polfer NC; Oomens J
    Mass Spectrom Rev; 2009; 28(3):468-94. PubMed ID: 19241457
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Standoff spectroscopy of surface adsorbed chemicals.
    Van Neste CW; Senesac LR; Thundat T
    Anal Chem; 2009 Mar; 81(5):1952-6. PubMed ID: 19186935
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Molecular recognition using receptor-free nanomechanical infrared spectroscopy based on a quantum cascade laser.
    Kim S; Lee D; Liu X; Van Neste C; Jeon S; Thundat T
    Sci Rep; 2013; 3():1111. PubMed ID: 23346368
    [TBL] [Abstract][Full Text] [Related]  

  • 15. External cavity tunable quantum cascade lasers and their applications to trace gas monitoring.
    Rao GN; Karpf A
    Appl Opt; 2011 Feb; 50(4):A100-15. PubMed ID: 21283214
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Broadband Mid-Infrared Stand-Off Reflection-Absorption Spectroscopy Using a Pulsed External Cavity Quantum Cascade Laser.
    Liu X; Chae I; Miriyala N; Lee D; Thundat T; Kim S
    Appl Spectrosc; 2017 Jul; 71(7):1494-1505. PubMed ID: 28664781
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of external-cavity quantum cascade infrared lasers to nanosecond time-resolved infrared spectroscopy of condensed-phase samples following pulse radiolysis.
    Grills DC; Cook AR; Fujita E; George MW; Preses JM; Wishart JF
    Appl Spectrosc; 2010 Jun; 64(6):563-70. PubMed ID: 20537222
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Molecular dispersion spectroscopy for chemical sensing using chirped mid-infrared quantum cascade laser.
    Wysocki G; Weidmann D
    Opt Express; 2010 Dec; 18(25):26123-40. PubMed ID: 21164961
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultra-sensitive mid-infrared evanescent field sensors combining thin-film strip waveguides with quantum cascade lasers.
    Wang X; Kim SS; Rossbach R; Jetter M; Michler P; Mizaikoff B
    Analyst; 2012 May; 137(10):2322-7. PubMed ID: 22249166
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Open path atmospheric spectroscopy using room temperature operated pulsed quantum cascade laser.
    Taslakov M; Simeonov V; van den Bergh H
    Spectrochim Acta A Mol Biomol Spectrosc; 2006 Apr; 63(5):1002-8. PubMed ID: 16503192
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.