214 related articles for article (PubMed ID: 23458265)
1. Newborn transepidermal water loss values: a reference dataset.
Kelleher MM; O'Carroll M; Gallagher A; Murray DM; Dunn Galvin A; Irvine AD; Hourihane JO
Pediatr Dermatol; 2013; 30(6):712-6. PubMed ID: 23458265
[TBL] [Abstract][Full Text] [Related]
2. Transepidermal Water Loss in Neonates: Baseline Values Using a Closed-Chamber System.
Mathanda TR; M Bhat R; Hegde P; Anand S
Pediatr Dermatol; 2016; 33(1):33-7. PubMed ID: 26758089
[TBL] [Abstract][Full Text] [Related]
3. Effect of radiant warmer on transepidermal water loss (TEWL) and skin hydration in preterm infants.
Maayan-Metzger A; Yosipovitch G; Hadad E; Sirota L
J Perinatol; 2004 Jun; 24(6):372-5. PubMed ID: 15071484
[TBL] [Abstract][Full Text] [Related]
4. Transepidermal water loss in full-term and pre-term infants.
Sedin G; Hammarlund K; Strömberg B
Acta Paediatr Scand Suppl; 1983; 305():27-31. PubMed ID: 6577775
[TBL] [Abstract][Full Text] [Related]
5. Transepidermal water loss and resting energy expenditure in preterm infants.
Maurer A; Micheli JL; Schütz Y; Freymond D; Jéquier E
Helv Paediatr Acta; 1984 Dec; 39(5-6):405-18. PubMed ID: 6543853
[TBL] [Abstract][Full Text] [Related]
6. Measurements of transepidermal water loss in newborn infants.
Sedin G; Hammarlund K; Nilsson GE; Strömberg B; Oberg PA
Clin Perinatol; 1985 Feb; 12(1):79-99. PubMed ID: 3978994
[TBL] [Abstract][Full Text] [Related]
7. Transepidermal water loss in newborns within the first 24 hours of life: baseline values and comparison with adults.
Raone B; Raboni R; Rizzo N; Simonazzi G; Patrizi A
Pediatr Dermatol; 2014; 31(2):191-5. PubMed ID: 24383609
[TBL] [Abstract][Full Text] [Related]
8. Transepidermal water loss and skin hydration in preterm infants during phototherapy.
Maayan-Metzger A; Yosipovitch G; Hadad E; Sirota L
Am J Perinatol; 2001 Nov; 18(7):393-6. PubMed ID: 11731893
[TBL] [Abstract][Full Text] [Related]
9. Measuring transepidermal water loss: a comparative in vivo study of condenser-chamber, unventilated-chamber and open-chamber systems.
Farahmand S; Tien L; Hui X; Maibach HI
Skin Res Technol; 2009 Nov; 15(4):392-8. PubMed ID: 19832948
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of a hand-held evaporimeter (VapoMeter) for the measurement of transepidermal water loss in healthy dogs.
Lau-Gillard PJ; Hill PB; Chesney CJ; Budleigh C; Immonen A
Vet Dermatol; 2010 Apr; 21(2):136-45. PubMed ID: 19961567
[TBL] [Abstract][Full Text] [Related]
11. Transepidermal water loss during halogen spotlight phototherapy in preterm infants.
Grünhagen DJ; de Boer MG; de Beaufort AJ; Walther FJ
Pediatr Res; 2002 Mar; 51(3):402-5. PubMed ID: 11861949
[TBL] [Abstract][Full Text] [Related]
12. Side-by-side comparison of an open-chamber (TM 300) and a closed-chamber (Vapometer™) transepidermal water loss meter.
Steiner M; Aikman-Green S; Prescott GJ; Dick FD
Skin Res Technol; 2011 Aug; 17(3):366-72. PubMed ID: 21492241
[TBL] [Abstract][Full Text] [Related]
13. Water-Holding and Transport Properties of Skin Stratum Corneum of Infants and Toddlers Are Different from Those of Adults: Studies in Three Geographical Regions and Four Ethnic Groups.
Mack MC; Chu MR; Tierney NK; Ruvolo E; Stamatas GN; Kollias N; Bhagat K; Ma L; Martin KM
Pediatr Dermatol; 2016 May; 33(3):275-82. PubMed ID: 26860213
[TBL] [Abstract][Full Text] [Related]
14. A closed unventilated chamber for the measurement of transepidermal water loss.
Nuutinen J; Alanen E; Autio P; Lahtinen MR; Harvima I; Lahtinen T
Skin Res Technol; 2003 May; 9(2):85-9. PubMed ID: 12709124
[TBL] [Abstract][Full Text] [Related]
15. Development of an in vitro model for premature neonatal skin: biophysical characterization using transepidermal water loss.
Sekkat N; Kalia YN; Guy RH
J Pharm Sci; 2004 Dec; 93(12):2936-40. PubMed ID: 15459948
[TBL] [Abstract][Full Text] [Related]
16. Skin care in the NICU patient: effects of wipes versus cloth and water on stratum corneum integrity.
Visscher M; Odio M; Taylor T; White T; Sargent S; Sluder L; Smith L; Flower T; Mason B; Rider M; Huebner A; Bondurant P
Neonatology; 2009; 96(4):226-34. PubMed ID: 19407468
[TBL] [Abstract][Full Text] [Related]
17. Closed-chamber transepidermal water loss measurement: microclimate, calibration and performance.
Imhof RE; De Jesus ME; Xiao P; Ciortea LI; Berg EP
Int J Cosmet Sci; 2009 Apr; 31(2):97-118. PubMed ID: 19175433
[TBL] [Abstract][Full Text] [Related]
18. Transepidermal water loss in cats: comparison of three differently clipped sites to assess the influence of hair coat on transepidermal water loss values.
Momota Y; Shimada K; Takami A; Akaogi H; Takasaki M; Mimura K; Azakami D; Ishioka K; Nakamura Y; Sako T
Vet Dermatol; 2013 Aug; 24(4):450-2, e100-1. PubMed ID: 23789740
[TBL] [Abstract][Full Text] [Related]
19. Validation of the VapoMeter, a closed unventilated chamber system to assess transepidermal water loss vs. the open chamber Tewameter.
De Paepe K; Houben E; Adam R; Wiesemann F; Rogiers V
Skin Res Technol; 2005 Feb; 11(1):61-9. PubMed ID: 15691261
[TBL] [Abstract][Full Text] [Related]
20. Measurement of transepidermal water loss in Tanzanian cot-nursed neonates and its relation to postnatal weight loss.
Thijs H; Massawe AW; Okken A; Coenraads PJ; Muskiet FA; Huisman M; Boersma ER
Acta Paediatr; 1996 Mar; 85(3):356-60. PubMed ID: 8695996
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]