204 related articles for article (PubMed ID: 23468380)
1. Comparison of six dilute russell viper venom time lupus anticoagulant screen/confirm assay kits.
McGlasson DL; Fritsma GA
Semin Thromb Hemost; 2013 Apr; 39(3):315-9. PubMed ID: 23468380
[TBL] [Abstract][Full Text] [Related]
2. A new-generation dilute Russell's viper venom time assay system for lupus anticoagulants: evaluation of detection utilising frozen reagents and controls.
Moore GW; Tugnait S; Savidge GF
Br J Biomed Sci; 2005; 62(3):127-32. PubMed ID: 16196459
[TBL] [Abstract][Full Text] [Related]
3. Newly developed dilute Russell's viper venom reagents for lupus anticoagulant detection with improved specificity.
Moore GW; Peyrafitte M; Dunois C; Amiral J
Lupus; 2018 Jan; 27(1):95-104. PubMed ID: 28549386
[TBL] [Abstract][Full Text] [Related]
4. The importance of locally derived reference ranges and standardized calculation of dilute Russell's viper venom time results in screening for lupus anticoagulant.
Gardiner C; MacKie IJ; Malia RG; Jones DW; Winter M; Leeming D; Taberner DA; Machin SJ; Greaves M
Br J Haematol; 2000 Dec; 111(4):1230-5. PubMed ID: 11167766
[TBL] [Abstract][Full Text] [Related]
5. Performance of Platelin LS and dilute Russell's viper venom for the screening of lupus anticoagulant in patients with venous thromboembolism.
Morelli VM; Rodrigues CA; Noguti MA; Matos MF; da Silveira RC; Ribeiro AA; Lourenço DM
Blood Coagul Fibrinolysis; 2007 Jul; 18(5):401-5. PubMed ID: 17581313
[TBL] [Abstract][Full Text] [Related]
6. Paired APTTs of low and high lupus anticoagulant sensitivity permit distinction from other abnormalities and achieve good lupus anticoagulant detection rates in conjunction with dRVVT.
Kumano O; Amiral J; Dunois C; Peyrafitte M; Moore GW
Int J Lab Hematol; 2019 Feb; 41(1):60-68. PubMed ID: 30248243
[TBL] [Abstract][Full Text] [Related]
7. Laboratory diagnosis of lupus anticoagulants for patients on oral anticoagulant treatment. Performance of dilute Russell viper venom test and silica clotting time in comparison with Staclot LA.
Tripodi A; Chantarangkul V; Clerici M; Mannucci PM
Thromb Haemost; 2002 Oct; 88(4):583-6. PubMed ID: 12362227
[TBL] [Abstract][Full Text] [Related]
8. [Evaluation of sensitivity and specificity of confirmatory assays for lupus anticoagulant (LA) detection].
Imoto K; Yasumuro Y; Taki M; Suzuki Y; Akatu S; Tajima C; Ichikawa Y
Rinsho Byori; 1996 Aug; 44(8):797-801. PubMed ID: 8816068
[TBL] [Abstract][Full Text] [Related]
9. Clinical importance of positive test results for lupus anticoagulant and anticardiolipin antibodies.
Proven A; Bartlett RP; Moder KG; Chang-Miller A; Cardel LK; Heit JA; Homburger HA; Petterson TM; Christianson TJ; Nichols WL
Mayo Clin Proc; 2004 Apr; 79(4):467-75. PubMed ID: 15065611
[TBL] [Abstract][Full Text] [Related]
10. Effects of direct oral anticoagulants on lupus anticoagulant assays in a real-life setting.
Antovic A; Norberg EM; Berndtsson M; Rasmuson A; Malmström RE; Skeppholm M; Antovic J
Thromb Haemost; 2017 Aug; 117(9):1700-1704. PubMed ID: 28640321
[TBL] [Abstract][Full Text] [Related]
11. Lupus anticoagulants and thrombosis: clinical association of different coagulation and immunologic tests.
Galli M; Dlott J; Norbis F; Ruggeri L; Cler L; Triplett DA; Barbui T
Thromb Haemost; 2000 Dec; 84(6):1012-6. PubMed ID: 11154107
[TBL] [Abstract][Full Text] [Related]
12. Frequent false-positive results of lupus anticoagulant tests in plasmas of patients receiving the new oral anticoagulants and enoxaparin.
Martinuzzo ME; Barrera LH; D 'adamo MA; Otaso JC; Gimenez MI; Oyhamburu J
Int J Lab Hematol; 2014 Apr; 36(2):144-50. PubMed ID: 24034808
[TBL] [Abstract][Full Text] [Related]
13. Lupus anticoagulant testing in Europe: an analysis of results from the first European Concerted Action on Thrombophilia (ECAT) survey using plasmas spiked with monoclonal antibodies against human beta2-glycoprotein I.
Arnout J; Meijer P; Vermylen J
Thromb Haemost; 1999 Jun; 81(6):929-34. PubMed ID: 10404770
[TBL] [Abstract][Full Text] [Related]
14. Presence of direct thrombin inhibitors can affect the results and interpretation of lupus anticoagulant testing.
Genzen JR; Miller JL
Am J Clin Pathol; 2005 Oct; 124(4):586-93. PubMed ID: 16146819
[TBL] [Abstract][Full Text] [Related]
15. Further evidence of false negative screening for lupus anticoagulants.
Moore GW; Henley A; Greenwood CK; Rangarajan S
Thromb Res; 2008; 121(4):477-84. PubMed ID: 17602725
[TBL] [Abstract][Full Text] [Related]
16. The sensitivity and specificity of commercial reagents for the detection of lupus anticoagulant show marked differences in performance between photo-optical and mechanical coagulometers.
Lawrie AS; Mackie IJ; Purdy G; Machin SJ
Thromb Haemost; 1999 May; 81(5):758-62. PubMed ID: 10365750
[TBL] [Abstract][Full Text] [Related]
17. Applying index of circulating anticoagulant to mixing tests with lupus anticoagulant screen and confirm reagents can distinguish with high specificity between lupus anticoagulants and direct factor Xa inhibitors.
Kumano O; Amiral J; Dunois C; Peyrafitte M; Moore GW
Int J Lab Hematol; 2021 Aug; 43(4):771-778. PubMed ID: 33974363
[TBL] [Abstract][Full Text] [Related]
18. False-positive lupus anticoagulant in patients receiving rivaroxaban: 24 h since the last dose are needed to exclude antiphospholipid syndrome.
Góralczyk T; Iwaniec T; Wypasek E; Undas A
Blood Coagul Fibrinolysis; 2015 Jun; 26(4):473-5. PubMed ID: 25402189
[TBL] [Abstract][Full Text] [Related]
19. Warfarin does not interfere with lupus anticoagulant detection by dilute Russell's viper venom time.
Olteanu H; Downes KA; Patel J; Praprotnik D; Sarode R
Clin Lab; 2009; 55(3-4):138-42. PubMed ID: 19462936
[TBL] [Abstract][Full Text] [Related]
20. The dilution effect of equal volume mixing studies compromises confirmation of inhibition by lupus anticoagulants even when mixture specific reference ranges are applied.
Moore GW; Savidge GF
Thromb Res; 2006; 118(4):523-8. PubMed ID: 16263154
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]