These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 23470559)

  • 21. Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner.
    Patel T; Peppard H; Williams MB
    Med Phys; 2016 Apr; 43(4):1720. PubMed ID: 27036570
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Dual Energy Method for Breast Imaging: A Simulation Study.
    Koukou V; Martini N; Michail C; Sotiropoulou P; Fountzoula C; Kalyvas N; Kandarakis I; Nikiforidis G; Fountos G
    Comput Math Methods Med; 2015; 2015():574238. PubMed ID: 26246848
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The relationship between the attenuation properties of breast microcalcifications and aluminum.
    Zanca F; Van Ongeval C; Marshall N; Meylaers T; Michielsen K; Marchal G; Bosmans H
    Phys Med Biol; 2010 Feb; 55(4):1057-68. PubMed ID: 20090185
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Quantification of Al-equivalent thickness of just visible microcalcifications in full field digital mammograms.
    Carton AK; Bosmans H; Vandenbroucke D; Souverijns G; Van Ongeval C; Dragusin O; Marchal G
    Med Phys; 2004 Jul; 31(7):2165-76. PubMed ID: 15305471
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Experimentally determined spectral optimization for dedicated breast computed tomography.
    Prionas ND; Huang SY; Boone JM
    Med Phys; 2011 Feb; 38(2):646-55. PubMed ID: 21452702
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Coronary calcium test phantom containing true CaHA microspheres for evaluation of advanced CT calcium scoring methods.
    Arnold BA; Budoff MJ; Child J; Xiang P; Mao SS
    J Cardiovasc Comput Tomogr; 2010; 4(5):322-9. PubMed ID: 20947042
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Calcium oxalate in breast lesions biopsied for calcification detected in screening mammography: incidence and clinical significance.
    Truong LD; Cartwright J; Alpert L
    Mod Pathol; 1992 Mar; 5(2):146-52. PubMed ID: 1574492
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Microcalcification detectability using a bench-top prototype photon-counting breast CT based on a Si strip detector.
    Cho HM; Ding H; Barber WC; Iwanczyk JS; Molloi S
    Med Phys; 2015 Jul; 42(7):4401-10. PubMed ID: 26133636
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Can a channelized Hotelling observer assess image quality in acquired mammographic images of an anthropomorphic breast phantom including image processing?
    Balta C; Bouwman RW; Sechopoulos I; Broeders MJM; Karssemeijer N; van Engen RE; Veldkamp WJH
    Med Phys; 2019 Feb; 46(2):714-725. PubMed ID: 30561108
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Acoustic radiation force contrast in MRI: detection of calcifications in tissue-mimicking phantoms.
    Mende J; Wild J; Ulucay D; Radicke M; Kofahl AL; Weber B; Krieg R; Maier K
    Med Phys; 2010 Dec; 37(12):6347-56. PubMed ID: 21302792
    [TBL] [Abstract][Full Text] [Related]  

  • 31. X-ray characterization of breast phantom materials.
    Byng JW; Mainprize JG; Yaffe MJ
    Phys Med Biol; 1998 May; 43(5):1367-77. PubMed ID: 9623665
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Disappearing breast calcifications: mammographic-pathologic discrepancy due to calcium oxalate.
    Dondalski M; Bernstein JR
    South Med J; 1992 Dec; 85(12):1252-4. PubMed ID: 1470975
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Peptides of Matrix Gla protein inhibit nucleation and growth of hydroxyapatite and calcium oxalate monohydrate crystals.
    Goiko M; Dierolf J; Gleberzon JS; Liao Y; Grohe B; Goldberg HA; de Bruyn JR; Hunter GK
    PLoS One; 2013; 8(11):e80344. PubMed ID: 24265810
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Discrimination analysis of breast calcifications using x-ray dark-field radiography.
    Rauch T; Rieger J; Pelzer G; Horn F; Erber R; Wunderle M; Emons J; Nabieva N; Fuhrich N; Michel T; Hartmann A; Fasching PA; Anton G
    Med Phys; 2020 Apr; 47(4):1813-1826. PubMed ID: 31977070
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Algorithmic 3D simulation of breast calcifications for digital mammography.
    Näppi J; Dean PB; Nevalainen O; Toikkanen S
    Comput Methods Programs Biomed; 2001 Jul; 66(1):115-24. PubMed ID: 11378233
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Nephrocalcinosis in Calcium Stone Formers Who Do Not have Systemic Disease.
    Bhojani N; Paonessa JE; Hameed TA; Worcester EM; Evan AP; Coe FL; Borofsky MS; Lingeman JE
    J Urol; 2015 Nov; 194(5):1308-12. PubMed ID: 25988516
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Monochromatic mammography using scanning multilayer X-ray mirrors.
    Windt DL
    Rev Sci Instrum; 2018 Aug; 89(8):083702. PubMed ID: 30184654
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The influence of heart rate, slice thickness, and calcification density on calcium scores using 64-slice multidetector computed tomography: a systematic phantom study.
    Groen JM; Greuter MJ; Schmidt B; Suess C; Vliegenthart R; Oudkerk M
    Invest Radiol; 2007 Dec; 42(12):848-55. PubMed ID: 18007157
    [TBL] [Abstract][Full Text] [Related]  

  • 39. 3D phantom for image quality assessment of mammography systems.
    Bermúdez J; Roque G; Calderón J; Pardo P; Sánchez M; Ramos V; Ávila C
    Phys Med Biol; 2023 Oct; 68(20):. PubMed ID: 37733054
    [No Abstract]   [Full Text] [Related]  

  • 40. Calcium oxalate crystals in breast biopsies. The missing microcalcifications.
    Tornos C; Silva E; el-Naggar A; Pritzker KP
    Am J Surg Pathol; 1990 Oct; 14(10):961-8. PubMed ID: 1698342
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.