These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
415 related articles for article (PubMed ID: 23473266)
21. Advantage and limitations of a minimally-invasive approach and early weight bearing in the treatment of tibial shaft fractures with locking plates. Adam P; Bonnomet F; Ehlinger M Orthop Traumatol Surg Res; 2012 Sep; 98(5):564-9. PubMed ID: 22906429 [TBL] [Abstract][Full Text] [Related]
22. Comparison of intramedullary nailing and minimal invasive plate osteosynthesis in the treatment of simple intra-articular fractures of the distal tibia (AO-OTA type 43 C1-C2). Beytemür O; Barış A; Albay C; Yüksel S; Çağlar S; Alagöz E Acta Orthop Traumatol Turc; 2017 Jan; 51(1):12-16. PubMed ID: 27825761 [TBL] [Abstract][Full Text] [Related]
23. Minimally Invasive Plate Osteosynthesis for Distal Tibia Fractures. Lai TC; Fleming JJ Clin Podiatr Med Surg; 2018 Apr; 35(2):223-232. PubMed ID: 29482791 [TBL] [Abstract][Full Text] [Related]
24. Surgical options for the treatment of severe tibial pilon fractures: a study of three techniques. Blauth M; Bastian L; Krettek C; Knop C; Evans S J Orthop Trauma; 2001; 15(3):153-60. PubMed ID: 11265004 [TBL] [Abstract][Full Text] [Related]
25. A Prospective Randomized Study on Operative Treatment for Simple Distal Tibial Fractures-Minimally Invasive Plate Osteosynthesis Versus Minimal Open Reduction and Internal Fixation. Kim JW; Kim HU; Oh CW; Kim JW; Park KC J Orthop Trauma; 2018 Jan; 32(1):e19-e24. PubMed ID: 28834822 [TBL] [Abstract][Full Text] [Related]
26. Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibial fracture: a retrospective study of 32 patients. Hasenboehler E; Rikli D; Babst R Injury; 2007 Mar; 38(3):365-70. PubMed ID: 17241634 [TBL] [Abstract][Full Text] [Related]
28. [The articular fracture of the lower limb]. Weber O; Müller MC; Goost H; Burger C; Kabir K; Wirtz D Z Orthop Unfall; 2009; 147(3):298-305. PubMed ID: 19551580 [TBL] [Abstract][Full Text] [Related]
29. Management of distal third tibial fractures: comparison of combined internal and external fixation with minimally invasive percutaneous plate osteosynthesis. Sun LJ; Wu ZP; Guo XS; Chen H Int Orthop; 2014 Nov; 38(11):2349-55. PubMed ID: 25086821 [TBL] [Abstract][Full Text] [Related]
30. [Treatment of Fractures of the Distal Third of Tibia Diaphysis by MIPO Technique]. Schwarz O; Majerníček M; Chomiak J Acta Chir Orthop Traumatol Cech; 2020; 87(2):114-119. PubMed ID: 32396512 [TBL] [Abstract][Full Text] [Related]
31. Minimally invasive plate osteosynthesis has equal safety to reamed intramedullary nails in treating Gustilo-Anderson type I, II and III-A open tibial shaft fractures. Galal S Injury; 2018 Apr; 49(4):866-870. PubMed ID: 29530513 [TBL] [Abstract][Full Text] [Related]
32. Comparison study of two surgical options for distal tibia fracture-minimally invasive plate osteosynthesis vs. open reduction and internal fixation. Cheng W; Li Y; Manyi W Int Orthop; 2011 May; 35(5):737-42. PubMed ID: 20517695 [TBL] [Abstract][Full Text] [Related]
33. Comparison of Early and Delayed Open Reduction and Internal Fixation for Treating Closed Tibial Pilon Fractures. Tang X; Liu L; Tu CQ; Li J; Li Q; Pei FX Foot Ankle Int; 2014 Jul; 35(7):657-64. PubMed ID: 24842898 [TBL] [Abstract][Full Text] [Related]
35. [Case control study on open reduction internal fixation (ORIF) and minimally invasive percutaneous plate osteosynthesis (MIPPO) for the treatment of proximal humerus fractures in aged]. Gao YB; Tong SL; Yu JH; Lu WJ Zhongguo Gu Shang; 2015 Apr; 28(4):335-9. PubMed ID: 26072616 [TBL] [Abstract][Full Text] [Related]
36. A retrospective comparison of double-hooked locking plates versus non-locking plates in minimally invasive percutaneous plate osteosynthesis for the treatment of comminuted distal fibular fractures accompanied by tibial Pilon fractures. Liu JH; Zhang Q; Wei GH; Liu L; Mu X; Li ML; Wu ZD J Orthop Surg Res; 2023 Apr; 18(1):287. PubMed ID: 37038161 [TBL] [Abstract][Full Text] [Related]
37. [Curative effect comparison of two methods of treatment for distal tibial fractures]. Dai JP; Yan YQ; Yu YF; Zhou X Zhongguo Gu Shang; 2009 May; 22(5):361-3. PubMed ID: 19522397 [TBL] [Abstract][Full Text] [Related]
38. [Case-control study on close reduction combined with minimally invasive percutaneous plate osteosynthesis for the treatment of distal fracture of tibial shaft]. Liu YW; Zheng YX; Wang XZ; Zhang H; Sun MZ; Wei Xiao-En ; Gu Xin-Feng ; Kuang Y; Zhang L; Shen ZL; Zhan HS; Shi YY Zhongguo Gu Shang; 2015 Mar; 28(3):230-4. PubMed ID: 25936192 [TBL] [Abstract][Full Text] [Related]
39. [Locked plating with minimally invasive percutaneous plate osteosynthesis versus intramedullary nailing of distal extra-articular tibial fracture: a retrospective study]. Yao Q; Ni J; Peng LB; Yu DX; Yuan XM Zhonghua Yi Xue Za Zhi; 2013 Dec; 93(47):3748-51. PubMed ID: 24548389 [TBL] [Abstract][Full Text] [Related]
40. [Close reduction combined with minimally invasive percutaneous plate osteosynthesis for proximal and distal tibial fractures: a report of 56 patients]. Liu YW; Kuang Y; Gu XF; Zheng YX; Li ZQ; Wei XE; Zhang MC; Zhan HS; Shi YY Zhongguo Gu Shang; 2013 Mar; 26(3):248-51. PubMed ID: 23795449 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]