These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 2347729)

  • 1. Design of metallic electron beam cones for an intraoperative therapy linear accelerator.
    Hogstrom KR; Boyer AL; Shiu AS; Ochran TG; Kirsner SM; Krispel F; Rich T
    Int J Radiat Oncol Biol Phys; 1990 May; 18(5):1223-32. PubMed ID: 2347729
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetry characteristics of metallic cones for intraoperative radiotherapy.
    Nyerick CE; Ochran TG; Boyer AL; Hogstrom KR
    Int J Radiat Oncol Biol Phys; 1991 Jul; 21(2):501-10. PubMed ID: 2061127
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Radiation protection measurements around a 12 MeV mobile dedicated IORT accelerator.
    Soriani A; Felici G; Fantini M; Paolucci M; Borla O; Evangelisti G; Benassi M; Strigari L
    Med Phys; 2010 Mar; 37(3):995-1003. PubMed ID: 20384235
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Design and dosimetry characteristics of a soft-docking system for intraoperative radiation therapy.
    Björk P; Knöös T; Nilsson P; Larsson K
    Int J Radiat Oncol Biol Phys; 2000 May; 47(2):527-33. PubMed ID: 10802382
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An intra-oral cone for an 18 MeV linear accelerator.
    Biggs PJ; Wang CC
    Int J Radiat Oncol Biol Phys; 1982 Jul; 8(7):1251-6. PubMed ID: 6811519
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Levels of leakage radiation from electron collimators of a linear accelerator.
    Das KR; Cramb JA; Millar RM; Kenny MB; Patterson WR; Ackerly TL; Perkins AE; Chongkitivitya K
    Med Phys; 1990; 17(6):1058-63. PubMed ID: 2126336
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement of the neutron leakage from a dedicated intraoperative radiation therapy electron linear accelerator and a conventional linear accelerator for 9, 12, 15(16), and 18(20) MeV electron energies.
    Jaradat AK; Biggs PJ
    Med Phys; 2008 May; 35(5):1711-7. PubMed ID: 18561646
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A non-docking intraoperative electron beam applicator system.
    Palta JR; Suntharalingam N
    Int J Radiat Oncol Biol Phys; 1989 Aug; 17(2):411-7. PubMed ID: 2502510
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of the contribution of capture gamma rays, x-ray leakage, and scatter to the photon dose at the maze door for a high energy medical electron accelerator using a Monte Carlo particle transport code.
    McGinley PH; Dhaba'an AH; Reft CS
    Med Phys; 2000 Jan; 27(1):225-30. PubMed ID: 10659761
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bremsstrahlung and Photoneutron leakage from steel shielding board impinged by 12-24 MeV electrons beams.
    Fujita Y; Saitoh H; Myojoyama A
    J Radiat Res; 2009 Jul; 50(4):363-9. PubMed ID: 19542692
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neutron production from a mobile linear accelerator operating in electron mode for intraoperative radiation therapy.
    Loi G; Dominietto M; Cannillo B; Ciocca M; Krengli M; Mones E; Negri E; Brambilla M
    Phys Med Biol; 2006 Feb; 51(3):695-702. PubMed ID: 16424589
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Shielding considerations for an operating room based intraoperative electron radiotherapy unit.
    Mills MD; Almond PR; Boyer AL; Ochran TG; Madigan W; Rich TA; Dally EB
    Int J Radiat Oncol Biol Phys; 1990 May; 18(5):1215-21. PubMed ID: 2112121
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Peripheral dose outside applicators in electron beams.
    Chow JC; Grigorov GN
    Phys Med Biol; 2006 Jun; 51(12):N231-40. PubMed ID: 16757855
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design of a non-docking intraoperative electron beam applicator system.
    Kharrati H; Aletti P; Guillemin F
    Radiother Oncol; 1994 Oct; 33(1):80-3. PubMed ID: 7878214
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A collimated detection system for assessing leakage dose from medical linear accelerators at the patient plane.
    Lonski P; Taylor ML; Franich RD; Kron T
    Australas Phys Eng Sci Med; 2014 Mar; 37(1):15-23. PubMed ID: 24318958
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance and beam characteristics of the Siemens Primus linear accelerator.
    Sontag MR; Steinberg TH
    Med Phys; 1999 May; 26(5):734-6. PubMed ID: 10360534
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetry of a prototype retractable eMLC for fixed-beam electron therapy.
    Hogstrom KR; Boyd RA; Antolak JA; Svatos MM; Faddegon BA; Rosenman JG
    Med Phys; 2004 Mar; 31(3):443-62. PubMed ID: 15070241
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Shielding design for a laser-accelerated proton therapy system.
    Fan J; Luo W; Fourkal E; Lin T; Li J; Veltchev I; Ma CM
    Phys Med Biol; 2007 Jul; 52(13):3913-30. PubMed ID: 17664585
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators.
    Al-Affan IA
    Med Phys; 2000 Jan; 27(1):231-8. PubMed ID: 10659762
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical Note: Mobile accelerator guidance using an optical tracker during docking in IOERT procedures.
    Marinetto E; Victores JG; García-Sevilla M; Muñoz M; Calvo FÁ; Balaguer C; Desco M; Pascau J
    Med Phys; 2017 Oct; 44(10):5061-5069. PubMed ID: 28736930
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.