These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 23477791)

  • 1. Loosening torque of prosthetic screws in metal-ceramic or metal-acrylic resin implant-supported dentures with different misfit levels.
    Bacchi A; Paludo L; Ferraz Mesquita M; Schuh C; Federizzi L; Oro Spazzin A
    J Biomech; 2013 Apr; 46(7):1358-62. PubMed ID: 23477791
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Screw joint stability after the application of retorque in implant-supported dentures under simulated masticatory conditions.
    Farina AP; Spazzin AO; Consani RL; Mesquita MF
    J Prosthet Dent; 2014 Jun; 111(6):499-504. PubMed ID: 24423456
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An in vitro comparison of joint stability of implant-supported fixed prosthetic suprastructures retained with different prosthetic screws and levels of fit under masticatory simulation conditions.
    Farina AP; Spazzin AO; Pantoja JM; Consani RL; Mesquita MF
    Int J Oral Maxillofac Implants; 2012; 27(4):833-8. PubMed ID: 22848885
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of retorque on loosening torque of prosthetic screws under two levels of fit of implant-supported dentures.
    Spazzin AO; Henrique GE; Nóbilo MA; Consani RL; Correr-Sobrinho L; Mesquita MF
    Braz Dent J; 2010 Jan; 21(1):12-7. PubMed ID: 20464315
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the effect of retightening and mechanical cycling on preload maintenance of retention screws.
    Delben JA; Gomes EA; Barão VA; Assunção WG
    Int J Oral Maxillofac Implants; 2011; 26(2):251-6. PubMed ID: 21483877
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fit and Stability of Screw-Retained Implant-Supported Frameworks Under Masticatory Simulation: Influence of Cylinder Type.
    Bhering CL; Marques Ida S; Takahashi JM; Barão VA; Consani RL; Mesquita MF
    J Prosthodont; 2016 Aug; 25(6):459-65. PubMed ID: 26465960
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of prosthetic screw material on joint stability in passive and non-passive implant-supported dentures.
    Spazzin AO; Henriques GE; de Arruda Nóbilo MA; Consani RL; Correr-Sobrinho L; Mesquita MF
    Open Dent J; 2009 Dec; 3():245-9. PubMed ID: 20148135
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Misfit of pure titanium frameworks: effect of veneer coverage and spark erosion process.
    Nakaoka MM; Nuñez-Pantoja JM; Takahashi JM; Consani RL; Mesquita MF
    Acta Odontol Scand; 2011 Jul; 69(4):238-42. PubMed ID: 21306198
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of superstructure materials and misfit on stress distribution in a single implant-supported prosthesis: a finite element analysis.
    Assunção WG; Gomes EA; Barão VA; Delben JA; Tabata LF; de Sousa EA
    J Craniofac Surg; 2010 May; 21(3):689-95. PubMed ID: 20485030
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro precision of fit of computer-aided designed and computer-aided manufactured titanium screw-retained fixed dental prostheses before and after ceramic veneering.
    Katsoulis J; Mericske-Stern R; Enkling N; Katsoulis K; Blatz MB
    Clin Oral Implants Res; 2015; 26(1):44-9. PubMed ID: 24289301
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correlation between vertical misfits and stresses transmitted to implants from metal frameworks.
    de Torres EM; Barbosa GA; Bernardes SR; de Mattos Mda G; Ribeiro RF
    J Biomech; 2011 Jun; 44(9):1735-9. PubMed ID: 21497352
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Retrievable metal ceramic implant-supported fixed prostheses with milled titanium frameworks and all-ceramic crowns: retrospective clinical study with up to 10 years of follow-up.
    Maló P; de Araújo Nobre M; Borges J; Almeida R
    J Prosthodont; 2012 Jun; 21(4):256-64. PubMed ID: 22339902
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modified section method for laser-welding of ill-fitting cp Ti and Ni-Cr alloy one-piece cast implant-supported frameworks.
    Tiossi R; Falcão-Filho H; Aguiar Júnior FA; Rodrigues RC; Mattos Mda G; Ribeiro RF
    J Oral Rehabil; 2010 May; 37(5):359-63. PubMed ID: 20149062
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Zirconium dioxide based dental restorations. Studies on clinical performance and fracture behaviour.
    Larsson C
    Swed Dent J Suppl; 2011; (213):9-84. PubMed ID: 21919311
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant-supported prostheses.
    Assunção WG; Jorge JR; Dos Santos PH; Barão VA; Gomes EA; Delben JA
    J Prosthodont; 2011 Oct; 20(7):523-7. PubMed ID: 21895835
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On cobalt-chrome frameworks in implant dentistry.
    Hjalmarsson L
    Swed Dent J Suppl; 2009; (201):3-83. PubMed ID: 20143574
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of different flask systems on tooth displacement and framework misfit in mandibular fixed implant-supported complete dentures.
    Caetano CR; Consani RL; Bacchi A; Correr AB; Dos Santos MB
    J Prosthodont Res; 2013 Jul; 57(3):213-8. PubMed ID: 23773375
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dental implant suprastructures using cobalt-chromium alloy compared with gold alloy framework veneered with ceramic or acrylic resin: a retrospective cohort study up to 18 years.
    Teigen K; Jokstad A
    Clin Oral Implants Res; 2012 Jul; 23(7):853-60. PubMed ID: 21692856
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Three-dimensional finite element analysis of vertical and angular misfit in implant-supported fixed prostheses.
    Assunção WG; Gomes EA; Rocha EP; Delben JA
    Int J Oral Maxillofac Implants; 2011; 26(4):788-96. PubMed ID: 21841989
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.
    Kim SG; Park JU; Jeong JH; Bae C; Bae TS; Chee W
    Int J Oral Maxillofac Implants; 2009; 24(6):1061-7. PubMed ID: 20162110
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.