These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

74 related articles for article (PubMed ID: 2347872)

  • 1. Fibrinogen-aluminum interaction: changes with oxide layer thickness onto metal surface.
    Sunny MC; Sharma CP
    J Biomed Mater Res; 1990 Apr; 24(4):455-62. PubMed ID: 2347872
    [No Abstract]   [Full Text] [Related]  

  • 2. Molecular simulation to characterize the adsorption behavior of a fibrinogen gamma-chain fragment.
    Agashe M; Raut V; Stuart SJ; Latour RA
    Langmuir; 2005 Feb; 21(3):1103-17. PubMed ID: 15667197
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Viscoelastic properties of fibrinogen adsorbed to the surface of biomaterials used in blood-contacting medical devices.
    Weber N; Pesnell A; Bolikal D; Zeltinger J; Kohn J
    Langmuir; 2007 Mar; 23(6):3298-304. PubMed ID: 17291015
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Albumin adsorption on to aluminium oxide and polyurethane surfaces.
    Sharma CP; Sunny MC
    Biomaterials; 1990 May; 11(4):255-7. PubMed ID: 2383620
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Thermal and chemical modification of titanium-aluminum-vanadium implant materials: effects on surface properties, glycoprotein adsorption, and MG63 cell attachment.
    MacDonald DE; Rapuano BE; Deo N; Stranick M; Somasundaran P; Boskey AL
    Biomaterials; 2004 Jul; 25(16):3135-46. PubMed ID: 14980408
    [TBL] [Abstract][Full Text] [Related]  

  • 6. PM-IRRAS investigation of the interaction of serum albumin and fibrinogen with a biomedical-grade stainless steel 316LVM surface.
    Desroches MJ; Chaudhary N; Omanovic S
    Biomacromolecules; 2007 Sep; 8(9):2836-44. PubMed ID: 17715960
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Pathohistological changes of various dog tissues exposed to aluminum oxide implants].
    Sulejmanagić H; Gojkov T; Kovacević M
    Stomatol Vjesn; 1983; 12(1-2):5-8. PubMed ID: 6581625
    [No Abstract]   [Full Text] [Related]  

  • 8. Protein interaction with tantalum: changes with oxide layer and hydroxyapatite at the interface.
    Sharma CP; Paul W
    J Biomed Mater Res; 1992 Sep; 26(9):1179-84. PubMed ID: 1331117
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [A cross sectional study of titanium plates surface-treated with anodic oxidation].
    Velich N; Kovács L; Németh Z; Szabó G
    Orv Hetil; 2006 Mar; 147(9):417-9. PubMed ID: 16619960
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Adherence of Streptococcus mutans to implant materials.
    Fujioka-Hirai Y; Akagawa Y; Minagi S; Tsuru H; Miyake Y; Suginaka H
    J Biomed Mater Res; 1987 Jul; 21(7):913-20. PubMed ID: 3038919
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dynamic protein adsorption at the polyurethane copolymer/water interface.
    Yaseen M; Salacinski HJ; Seifalian AM; Lu JR
    Biomed Mater; 2008 Sep; 3(3):034123. PubMed ID: 18765894
    [TBL] [Abstract][Full Text] [Related]  

  • 12. AFM force spectroscopy of the fibrinogen adsorption process onto dental implants.
    Boukari A; Francius G; Hemmerlé J
    J Biomed Mater Res A; 2006 Sep; 78(3):466-72. PubMed ID: 16721792
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adsorption of fibrinogen on a biomedical-grade stainless steel 316LVM surface: a PM-IRRAS study of the adsorption thermodynamics, kinetics and secondary structure changes.
    Desroches MJ; Omanovic S
    Phys Chem Chem Phys; 2008 May; 10(18):2502-12. PubMed ID: 18446250
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Raman spectroscopy for the study of porous composite alumina coating.
    Bertoluzza A; Fagnano C; Tinti A; Toni A; Ciapetti G; Sudanese A; Cattaneo C
    J Biomed Mater Res; 1989 May; 23(5):523-8. PubMed ID: 2715164
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Protein adsorption on low-temperature isotropic carbon: I. Protein conformational change probed by differential scanning calorimetry.
    Feng L; Andrade JD
    J Biomed Mater Res; 1994 Jun; 28(6):735-43. PubMed ID: 8071385
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Interpretation of protein adsorption: surface-induced conformational changes.
    Roach P; Farrar D; Perry CC
    J Am Chem Soc; 2005 Jun; 127(22):8168-73. PubMed ID: 15926845
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Aluminum oxide ceramic PORP and TORP prostheses].
    Broess AA
    Acta Otorhinolaryngol Belg; 1983; 37(5):726-34. PubMed ID: 6659918
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Endosseous screw-implants in aluminium ceramic (crystalline bone screw and Cerasand)].
    Vanhakendover S
    Actual Odontostomatol (Paris); 1987 Dec; 41(160 Spec No):627-40. PubMed ID: 3332981
    [No Abstract]   [Full Text] [Related]  

  • 19. Semi-conducting properties of titanium dioxide surfaces on titanium implants.
    Petersson IU; Löberg JE; Fredriksson AS; Ahlberg EK
    Biomaterials; 2009 Sep; 30(27):4471-9. PubMed ID: 19524291
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fibrinogen adsorption, platelet adhesion and thrombin generation at heparinized surfaces exposed to flowing blood.
    Keuren JF; Wielders SJ; Willems GM; Morra M; Lindhout T
    Thromb Haemost; 2002 Apr; 87(4):742-7. PubMed ID: 12008960
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.