130 related articles for article (PubMed ID: 23479183)
1. Evaluation of GAFCHROMIC EBT2 dosimetry for the low dose range using a flat-bed scanner with the reflection mode.
Gotanda T; Katsuda T; Akagawa T; Gotanda R; Tabuchi A; Yamamoto K; Kuwano T; Yatake H; Yabunaka K; Takeda Y
Australas Phys Eng Sci Med; 2013 Mar; 36(1):59-63. PubMed ID: 23479183
[TBL] [Abstract][Full Text] [Related]
2. Gafchromic EBT2 film dosimetry in reflection mode with a novel plan-based calibration method.
Mendez I; Hartman V; Hudej R; Strojnik A; Casar B
Med Phys; 2013 Jan; 40(1):011720. PubMed ID: 23298090
[TBL] [Abstract][Full Text] [Related]
3. Variations in dose distribution and optical properties of Gafchromic(TM) EBT2 film according to scanning mode.
Park S; Kang SK; Cheong KH; Hwang T; Kim H; Han T; Lee MY; Kim K; Bae H; Su Kim H; Han Kim J; Jae Oh S; Suh JS
Med Phys; 2012 May; 39(5):2524-35. PubMed ID: 22559623
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of effective energy using radiochromic film and a step-shaped aluminum filter.
Gotanda T; Katsuda T; Gotanda R; Tabuchi A; Yamamoto K; Kuwano T; Yatake H; Kashiyama K; Yabunaka K; Akagawa T; Takeda Y
Australas Phys Eng Sci Med; 2011 Jun; 34(2):213-22. PubMed ID: 21437731
[TBL] [Abstract][Full Text] [Related]
5. An investigation into factors affecting the precision of CT radiation dose profile width measurements using radiochromic films.
Li B; Behrman RH
Med Phys; 2015 Apr; 42(4):1765-72. PubMed ID: 25832066
[TBL] [Abstract][Full Text] [Related]
6. Characteristics of Gafchromic XRQA2 films for kV image dose measurement.
Giaddui T; Cui Y; Galvin J; Chen W; Yu Y; Xiao Y
Med Phys; 2012 Feb; 39(2):842-50. PubMed ID: 22320794
[TBL] [Abstract][Full Text] [Related]
7. The response of the new MD-V2-55 radiochromic film exposed to 60Co gamma rays.
Massillon-Jl G; Zúñiga-Meneses L
Phys Med Biol; 2010 Sep; 55(18):5437-49. PubMed ID: 20736498
[TBL] [Abstract][Full Text] [Related]
8. Potential errors in optical density measurements due to scanning side in EBT and EBT2 Gafchromic film dosimetry.
Desroches J; Bouchard H; Lacroix F
Med Phys; 2010 Apr; 37(4):1565-70. PubMed ID: 20443477
[TBL] [Abstract][Full Text] [Related]
9. Evaluation and optimization of the new EBT2 radiochromic film dosimetry system for patient dose verification in radiotherapy.
Richley L; John AC; Coomber H; Fletcher S
Phys Med Biol; 2010 May; 55(9):2601-17. PubMed ID: 20393235
[TBL] [Abstract][Full Text] [Related]
10. Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance.
Fuss M; Sturtewagen E; De Wagter C; Georg D
Phys Med Biol; 2007 Jul; 52(14):4211-25. PubMed ID: 17664604
[TBL] [Abstract][Full Text] [Related]
11. Radiochromic film dosimetry: considerations on precision and accuracy for EBT2 and EBT3 type films.
Dreindl R; Georg D; Stock M
Z Med Phys; 2014 May; 24(2):153-63. PubMed ID: 24055395
[TBL] [Abstract][Full Text] [Related]
12. Precise radiochromic film dosimetry using a flat-bed document scanner.
Devic S; Seuntjens J; Sham E; Podgorsak EB; Schmidtlein CR; Kirov AS; Soares CG
Med Phys; 2005 Jul; 32(7):2245-53. PubMed ID: 16121579
[TBL] [Abstract][Full Text] [Related]
13. Precise radiochromic film dosimetry using a flat-bed document scanner.
Devic S; Seuntjens J; Sham E; Podgorsak EB; Schmidtlein CR; Kirov AS; Soares CG
Med Phys; 2005 Jul; 32(7Part1):2245-2253. PubMed ID: 28493574
[TBL] [Abstract][Full Text] [Related]
14. Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.
Paelinck L; De Neve W; De Wagter C
Phys Med Biol; 2007 Jan; 52(1):231-42. PubMed ID: 17183138
[TBL] [Abstract][Full Text] [Related]
15. Calibration of EBT2 film by the PDD method with scanner non-uniformity correction.
Chang L; Chui CS; Ding HJ; Hwang IM; Ho SY
Phys Med Biol; 2012 Sep; 57(18):5875-87. PubMed ID: 22951587
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
Ferreira BC; Lopes MC; Capela M
Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
[TBL] [Abstract][Full Text] [Related]
17. Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams.
Rampado O; Garelli E; Deagostini S; Ropolo R
Phys Med Biol; 2006 Jun; 51(11):2871-81. PubMed ID: 16723772
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance.
Aland T; Kairn T; Kenny J
Australas Phys Eng Sci Med; 2011 Jun; 34(2):251-60. PubMed ID: 21465275
[TBL] [Abstract][Full Text] [Related]
19. Dose and absorption spectra response of EBT2 Gafchromic film to high energy x-rays.
Butson MJ; Cheung T; Yu PK; Alnawaf H
Australas Phys Eng Sci Med; 2009 Dec; 32(4):196-202. PubMed ID: 20169838
[TBL] [Abstract][Full Text] [Related]
20. Dose-response linearization in radiochromic film dosimetry based on multichannel normalized pixel value with an integrated spectral correction for scanner response variations.
Aldelaijan S; Devic S; Papaconstadopoulos P; Bekerat H; Cormack RA; Seuntjens J; Buzurovic IM
Med Phys; 2019 Nov; 46(11):5336-5349. PubMed ID: 31529516
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]