These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
462 related articles for article (PubMed ID: 23480085)
1. Complications of Poly Implant Prothèse breast implants: the current discussion. Kolios L; Hirche C; Spiethoff A; Daigeler A; Lehnhardt M Expert Rev Med Devices; 2013 Mar; 10(2):167-70. PubMed ID: 23480085 [TBL] [Abstract][Full Text] [Related]
2. Silicone lymphadenopathy after breast augmentation: case reports, review of the literature, and current thoughts. Zambacos GJ; Molnar C; Mandrekas AD Aesthetic Plast Surg; 2013 Apr; 37(2):278-89. PubMed ID: 23354761 [TBL] [Abstract][Full Text] [Related]
3. Silicone lymphadenopathy: an unexpected cause of neck lumps. Omakobia E; Porter G; Armstrong S; Denton K J Laryngol Otol; 2012 Sep; 126(9):970-3. PubMed ID: 22672792 [TBL] [Abstract][Full Text] [Related]
4. The "PIP problem": clinical and histologic characteristics. Correia-Sá I; Rodrigues-Pereira P; Marques M Aesthetic Plast Surg; 2013 Oct; 37(5):936-40. PubMed ID: 23943050 [TBL] [Abstract][Full Text] [Related]
5. Axillary lipogranuloma mimicking carcinoma metastasis after silicone breast implant rupture: a case report. Gundeslioglu AO; Hakverdi S; Erdem O; Ozen EC; Inan I; Emlik D J Plast Reconstr Aesthet Surg; 2013 Mar; 66(3):e72-5. PubMed ID: 23245917 [TBL] [Abstract][Full Text] [Related]
6. [Imaging in silicone breast implantation]. Gielens M; Koolen PG; Hermens RA; Rutten MJ Ned Tijdschr Geneeskd; 2013; 157(47):A6412. PubMed ID: 24252405 [TBL] [Abstract][Full Text] [Related]
7. Poly Implant Prothèse and Rofil Substandard Breast Implant Explantations from a Large German Single Centre from 2011 to 2014: A Comparative Study. Billner M; Wirthmann A; Reif S; Rieger UM Aesthetic Plast Surg; 2016 Aug; 40(4):507-13. PubMed ID: 27286854 [TBL] [Abstract][Full Text] [Related]
8. Locoregional silicone spread after high cohesive gel silicone implant rupture. Lahiri A; Waters R J Plast Reconstr Aesthet Surg; 2006; 59(8):885-6. PubMed ID: 16876092 [TBL] [Abstract][Full Text] [Related]
9. PIP silicone breast implants: rupture rates based on the explantation of 676 implants in a single surgeon series. Quaba O; Quaba A J Plast Reconstr Aesthet Surg; 2013 Sep; 66(9):1182-7. PubMed ID: 23725742 [TBL] [Abstract][Full Text] [Related]
12. [Breast augmentation by Poly Implant Prothèses silicone implants: retrospective study about 99 patients. Rupture analysis and management]. Aktouf A; Auquit-Auckbur I; Coquerel-Beghin D; Delpierre V; Milliez PY Ann Chir Plast Esthet; 2012 Dec; 57(6):558-66. PubMed ID: 22651997 [TBL] [Abstract][Full Text] [Related]
13. Complication of Ruptured Poly Implant Prothèse Kim J; Chang H; Park JU Aesthetic Plast Surg; 2019 Feb; 43(1):46-52. PubMed ID: 30288565 [TBL] [Abstract][Full Text] [Related]
14. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature. Klein D; Hadad E; Wiser I; Wolf O; Itzhaki Shapira O; Fucks S; Heller L Ann Plast Surg; 2018 Jan; 80(1):5-9. PubMed ID: 29166315 [TBL] [Abstract][Full Text] [Related]
19. High-resolution ultrasound in the detection of silicone gel breast implant shell failure: background, in vitro studies, and early clinical results. Bengtson BP; Eaves FF Aesthet Surg J; 2012 Feb; 32(2):157-74. PubMed ID: 22328687 [TBL] [Abstract][Full Text] [Related]
20. [Axillary silicon lymphadenopathy after breast augmentation]. Falk S; Neudert H; Radeljic A Geburtshilfe Frauenheilkd; 1996 Jan; 56(1):55-7. PubMed ID: 8852787 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]