These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 23493956)

  • 1. Universally applicable three-dimensional hydrodynamic microfluidic flow focusing.
    Chiu YJ; Cho SH; Mei Z; Lien V; Wu TF; Lo YH
    Lab Chip; 2013 May; 13(9):1803-9. PubMed ID: 23493956
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Single channel layer, single sheath-flow inlet microfluidic flow cytometer with three-dimensional hydrodynamic focusing.
    Lin SC; Yen PW; Peng CC; Tung YC
    Lab Chip; 2012 Sep; 12(17):3135-41. PubMed ID: 22763751
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional hydrodynamic focusing in a microfluidic Coulter counter.
    Scott R; Sethu P; Harnett CK
    Rev Sci Instrum; 2008 Apr; 79(4):046104. PubMed ID: 18447562
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microflow cytometers with integrated hydrodynamic focusing.
    Frankowski M; Theisen J; Kummrow A; Simon P; Ragusch H; Bock N; Schmidt M; Neukammer J
    Sensors (Basel); 2013 Apr; 13(4):4674-93. PubMed ID: 23571670
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microfluidic impedance-based flow cytometry.
    Cheung KC; Di Berardino M; Schade-Kampmann G; Hebeisen M; Pierzchalski A; Bocsi J; Mittag A; Tárnok A
    Cytometry A; 2010 Jul; 77(7):648-66. PubMed ID: 20583276
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dynamic reversibility of hydrodynamic focusing for recycling sheath fluid.
    Hashemi N; Howell PB; Erickson JS; Golden JP; Ligler FS
    Lab Chip; 2010 Aug; 10(15):1952-9. PubMed ID: 20480064
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Single-layer planar on-chip flow cytometer using microfluidic drifting based three-dimensional (3D) hydrodynamic focusing.
    Mao X; Lin SC; Dong C; Huang TJ
    Lab Chip; 2009 Jun; 9(11):1583-9. PubMed ID: 19458866
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Spark-generated microbubble cell sorter for microfluidic flow cytometry.
    Zhao J; You Z
    Cytometry A; 2018 Feb; 93(2):222-231. PubMed ID: 29346713
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sub-micrometer-precision, three-dimensional (3D) hydrodynamic focusing via "microfluidic drifting".
    Nawaz AA; Zhang X; Mao X; Rufo J; Lin SC; Guo F; Zhao Y; Lapsley M; Li P; McCoy JP; Levine SJ; Huang TJ
    Lab Chip; 2014 Jan; 14(2):415-23. PubMed ID: 24287742
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Inertial microfluidics for sheath-less high-throughput flow cytometry.
    Bhagat AA; Kuntaegowdanahalli SS; Kaval N; Seliskar CJ; Papautsky I
    Biomed Microdevices; 2010 Apr; 12(2):187-95. PubMed ID: 19946752
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determining blood cell size using microfluidic hydrodynamics.
    Inglis DW; Davis JA; Zieziulewicz TJ; Lawrence DA; Austin RH; Sturm JC
    J Immunol Methods; 2008 Jan; 329(1-2):151-6. PubMed ID: 18036608
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An adaptive three-dimensional hydrodynamic focusing microfluidic impedance flow cytometer.
    Zhou Y; Wang J; Liu T; Wu M; Lan Y; Jia C; Zhao J
    Analyst; 2023 Jul; 148(14):3239-3246. PubMed ID: 37341575
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hydrodynamic flow cytometer performance enhancement by two-dimensional acoustic focusing.
    Li Z; Li P; Xu J; Shao W; Yang C; Cui Y
    Biomed Microdevices; 2020 Mar; 22(2):27. PubMed ID: 32222836
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hydrodynamic gating valve for microfluidic fluorescence-activated cell sorting.
    Chen P; Feng X; Hu R; Sun J; Du W; Liu BF
    Anal Chim Acta; 2010 Mar; 663(1):1-6. PubMed ID: 20172088
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Micro-impedance cytometry for detection and analysis of micron-sized particles and bacteria.
    Bernabini C; Holmes D; Morgan H
    Lab Chip; 2011 Feb; 11(3):407-12. PubMed ID: 21060945
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microfluidic impedance cytometry device with N-shaped electrodes for lateral position measurement of single cells/particles.
    Yang D; Ai Y
    Lab Chip; 2019 Nov; 19(21):3609-3617. PubMed ID: 31517354
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Field-free, sheathless cell focusing in exponentially expanding hydrophoretic channels for microflow cytometry.
    Song S; Choi S
    Cytometry A; 2013 Nov; 83(11):1034-40. PubMed ID: 24115760
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sheathless size-based acoustic particle separation.
    Guldiken R; Jo MC; Gallant ND; Demirci U; Zhe J
    Sensors (Basel); 2012; 12(1):905-22. PubMed ID: 22368502
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A microfluidic cytometer for white blood cell analysis.
    Peng T; Su X; Cheng X; Wei Z; Su X; Li Q
    Cytometry A; 2021 Nov; 99(11):1107-1113. PubMed ID: 34369647
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Microfluidics for flow cytometric analysis of cells and particles.
    Huh D; Gu W; Kamotani Y; Grotberg JB; Takayama S
    Physiol Meas; 2005 Jun; 26(3):R73-98. PubMed ID: 15798290
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.