138 related articles for article (PubMed ID: 2349612)
1. Suitability of collection tubes with separator gels for therapeutic drug monitoring.
Koch TR; Platoff G
Ther Drug Monit; 1990 May; 12(3):277-80. PubMed ID: 2349612
[TBL] [Abstract][Full Text] [Related]
2. Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations.
Dasgupta A; Dean R; Saldana S; Kinnaman G; McLawhon RW
Am J Clin Pathol; 1994 Apr; 101(4):456-61. PubMed ID: 8160636
[TBL] [Abstract][Full Text] [Related]
3. Assessment of the Corvac blood collection tube for drug specimen processing.
Devine JE
Ther Drug Monit; 1986; 8(2):241-3. PubMed ID: 3726942
[TBL] [Abstract][Full Text] [Related]
4. Effect of serum separator tubes on free and total phenytoin and carbamazepine serum concentrations.
Mauro LS; Mauro VF
Ther Drug Monit; 1991 May; 13(3):240-3. PubMed ID: 1926278
[TBL] [Abstract][Full Text] [Related]
5. Stability of therapeutic drug measurement in specimens collected in VACUTAINER plastic blood-collection tubes.
Dasgupta A; Blackwell W; Bard D
Ther Drug Monit; 1996 Jun; 18(3):306-9. PubMed ID: 8738774
[TBL] [Abstract][Full Text] [Related]
6. Effect of serum separator blood collection tubes on drug concentrations.
Quattrocchi F; Karnes HT; Robinson JD; Hendeles L
Ther Drug Monit; 1983; 5(3):359-62. PubMed ID: 6356497
[TBL] [Abstract][Full Text] [Related]
7. Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum.
Bergqvist Y; Eckerbom S; Funding L
Clin Chem; 1984 Mar; 30(3):465-6. PubMed ID: 6697500
[TBL] [Abstract][Full Text] [Related]
8. Time-dependent absorption of therapeutic drugs by the gel of the Greiner Vacuette blood collection tube.
Dasgupta A; Yared MA; Wells A
Ther Drug Monit; 2000 Aug; 22(4):427-31. PubMed ID: 10942183
[TBL] [Abstract][Full Text] [Related]
9. Stability of therapeutic drugs in serum collected in vacutainer serum separator tubes containing a new gel (SST II).
Bush V; Blennerhasset J; Wells A; Dasgupta A
Ther Drug Monit; 2001 Jun; 23(3):259-62. PubMed ID: 11360035
[TBL] [Abstract][Full Text] [Related]
10. Stability of drug concentrations in plasma stored in serum separator blood collection tubes.
Bailey DN; Coffee JJ; Briggs JR
Ther Drug Monit; 1988; 10(3):352-4. PubMed ID: 3176115
[TBL] [Abstract][Full Text] [Related]
11. Effects of contaminants in blood-collection devices on measurements of therapeutic drugs.
Ji SQ; Evenson MA
Clin Chem; 1983 Mar; 29(3):456-61. PubMed ID: 6825254
[TBL] [Abstract][Full Text] [Related]
12. Do evacuated blood collection tubes interfere with therapeutic drug monitoring?
Janknegt R; Lohman JJ; Hooymans PM; Merkus FW
Pharm Weekbl Sci; 1983 Dec; 5(6):287-90. PubMed ID: 6664820
[TBL] [Abstract][Full Text] [Related]
13. Monoject Samplette capillary blood container with serum separator evaluated for collection of specimens for therapeutic drug assays and common clinical-chemical tests.
Landt M; Norling LL; Steelman M; Smith CH
Clin Chem; 1986 Mar; 32(3):523-6. PubMed ID: 3948399
[TBL] [Abstract][Full Text] [Related]
14. Sterile Corvac silicone gel tubes: efficacy and storage capabilities.
Frankel S
Am J Clin Pathol; 1984 Feb; 81(2):240-2. PubMed ID: 6421148
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of evacuated blood-collection tubes: effects of three types of polymeric separators on therapeutic drug-monitoring specimens.
Landt M; Smith CH; Hortin GL
Clin Chem; 1993 Aug; 39(8):1712-7. PubMed ID: 8353961
[TBL] [Abstract][Full Text] [Related]
16. Suitability of collection tubes with separator gels for collecting and storing blood samples for therapeutic drug monitoring (TDM).
Karppi J; Akerman KK; Parviainen M
Clin Chem Lab Med; 2000 Apr; 38(4):313-20. PubMed ID: 10928651
[TBL] [Abstract][Full Text] [Related]
17. Where clinical chemistry meets medicinal chemistry. Systematic analysis of physico-chemical properties predicts stability of common used drugs in gel separator serum tubes.
Steuer C; Huber AR; Bernasconi L
Clin Chim Acta; 2016 Nov; 462():23-27. PubMed ID: 27567701
[TBL] [Abstract][Full Text] [Related]
18. A Multicenter Evaluation of a Nongel Mechanical Separator Plasma Blood Collection Tube for Testing of Selected Therapeutic Drugs.
Morosyuk S; Berube J; Christenson R; Wu AHB; Uettwiller-Geiger D; Palicka V; Prusa R; Zima T; Shaw K; Plokhoy E; Ahuja AJ; Stankovic AK
J Appl Lab Med; 2020 Jul; 5(4):671-685. PubMed ID: 32603441
[TBL] [Abstract][Full Text] [Related]
19. Solution densities and estimated total protein contents associated with inappropriate flotation of separator gel in different blood collection tubes.
Faught RC; Marshall J; Bornhorst J
Arch Pathol Lab Med; 2011 Sep; 135(9):1081-4. PubMed ID: 21877989
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of serum and rapid serum separator collection tubes for therapeutic drug assays.
Garza KY; Carter J; Mercer A; Jarrar P; Martin J; Daughtry S; Mahomes A; Knezevic CE
Clin Biochem; 2023 May; 115():81-85. PubMed ID: 36027943
[TBL] [Abstract][Full Text] [Related]