398 related articles for article (PubMed ID: 23497843)
1. Laser-induced fluorescence thermometry of heating in water from short bursts of high intensity focused ultrasound.
Al-Qraini MM; Canney MS; Oweis GF
Ultrasound Med Biol; 2013 Apr; 39(4):647-59. PubMed ID: 23497843
[TBL] [Abstract][Full Text] [Related]
2. Magnetic resonance imaging for the exploitation of bubble-enhanced heating by high-intensity focused ultrasound: a feasibility study in ex vivo liver.
Elbes D; Denost Q; Robert B; Köhler MO; Tanter M; Bruno Q
Ultrasound Med Biol; 2014 May; 40(5):956-64. PubMed ID: 24462160
[TBL] [Abstract][Full Text] [Related]
3. Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney.
Quesson B; Laurent C; Maclair G; de Senneville BD; Mougenot C; Ries M; Carteret T; Rullier A; Moonen CT
NMR Biomed; 2011 Feb; 24(2):145-53. PubMed ID: 21344531
[TBL] [Abstract][Full Text] [Related]
4. Pre-clinical study of in vivo magnetic resonance-guided bubble-enhanced heating in pig liver.
Elbes D; Denost Q; Laurent C; Trillaud H; Rullier A; Quesson B
Ultrasound Med Biol; 2013 Aug; 39(8):1388-97. PubMed ID: 23562012
[TBL] [Abstract][Full Text] [Related]
5. Determining temperature distribution in tissue in the focal plane of the high (>100 W/cm(2)) intensity focused ultrasound beam using phase shift of ultrasound echoes.
Karwat P; Kujawska T; Lewin PA; Secomski W; Gambin B; Litniewski J
Ultrasonics; 2016 Feb; 65():211-9. PubMed ID: 26498063
[TBL] [Abstract][Full Text] [Related]
6. HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat.
Kyriakou Z; Corral-Baques MI; Amat A; Coussios CC
Ultrasound Med Biol; 2011 Apr; 37(4):568-79. PubMed ID: 21371810
[TBL] [Abstract][Full Text] [Related]
7. Augmentation of HIFU-induced heating with fibers embedded in a phantom.
Labuda CP; Church CC
Ultrasound Med Biol; 2011 Mar; 37(3):442-9. PubMed ID: 21316561
[TBL] [Abstract][Full Text] [Related]
8. Theoretically Estimating the Acoustic Intensity of High-Intensity Focused Ultrasound (HIFU) Using Infrared Thermography.
Zhou Y
IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Jun; 67(6):1159-1165. PubMed ID: 31944971
[TBL] [Abstract][Full Text] [Related]
9. Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model.
Adams MS; Salgaonkar VA; Plata-Camargo J; Jones PD; Pascal-Tenorio A; Chen HY; Bouley DM; Sommer G; Pauly KB; Diederich CJ
Med Phys; 2016 Jul; 43(7):4184. PubMed ID: 27370138
[TBL] [Abstract][Full Text] [Related]
10. Correction of proton resonance frequency shift MR-thermometry errors caused by heat-induced magnetic susceptibility changes during high intensity focused ultrasound ablations in tissues containing fat.
Baron P; Deckers R; de Greef M; Merckel LG; Bakker CJ; Bouwman JG; Bleys RL; van den Bosch MA; Bartels LW
Magn Reson Med; 2014 Dec; 72(6):1580-9. PubMed ID: 24347129
[TBL] [Abstract][Full Text] [Related]
11. Impact of preconditioning pulse on lesion formation during high-intensity focused ultrasound histotripsy.
Xu J; Bigelow TA; Riesberg GM
Ultrasound Med Biol; 2012 Nov; 38(11):1918-29. PubMed ID: 22929656
[TBL] [Abstract][Full Text] [Related]
12. Improved intercostal HIFU ablation using a phased array transducer based on Fermat's spiral and Voronoi tessellation: A numerical evaluation.
Ramaekers P; Ries M; Moonen CT; de Greef M
Med Phys; 2017 Mar; 44(3):1071-1088. PubMed ID: 28058731
[TBL] [Abstract][Full Text] [Related]
13. Intercostal high intensity focused ultrasound for liver ablation: The influence of beam shaping on sonication efficacy and near-field risks.
de Greef M; Schubert G; Wijlemans JW; Koskela J; Bartels LW; Moonen CT; Ries M
Med Phys; 2015 Aug; 42(8):4685-97. PubMed ID: 26233196
[TBL] [Abstract][Full Text] [Related]
14. Monitoring of thermal therapy based on shear modulus changes: I. shear wave thermometry.
Arnal B; Pernot M; Tanter M
IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Feb; 58(2):369-78. PubMed ID: 21342822
[TBL] [Abstract][Full Text] [Related]
15. Harmonic motion imaging for focused ultrasound (HMIFU): a fully integrated technique for sonication and monitoring of thermal ablation in tissues.
Maleke C; Konofagou EE
Phys Med Biol; 2008 Mar; 53(6):1773-93. PubMed ID: 18367802
[TBL] [Abstract][Full Text] [Related]
16. Ultrasonography-based 2D motion-compensated HIFU sonication integrated with reference-free MR temperature monitoring: a feasibility study ex vivo.
Auboiroux V; Petrusca L; Viallon M; Goget T; Becker CD; Salomir R
Phys Med Biol; 2012 May; 57(10):N159-71. PubMed ID: 22517112
[TBL] [Abstract][Full Text] [Related]
17. The correlation between bubble-enhanced HIFU heating and cavitation power.
Farny CH; Glynn Holt R; Roy RA
IEEE Trans Biomed Eng; 2010 Jan; 57(1):175-84. PubMed ID: 19651548
[TBL] [Abstract][Full Text] [Related]
18. A feasibility study of temperature rise measurement in a tissue phantom as an alternative way for characterization of the therapeutic high intensity focused ultrasonic field.
Chen D; Fan T; Zhang D; Wu J
Ultrasonics; 2009 Dec; 49(8):733-42. PubMed ID: 19576607
[TBL] [Abstract][Full Text] [Related]
19. Spatio-temporal quantitative thermography of pre-focal interactions between high intensity focused ultrasound and the rib cage.
Petrusca L; Salomir R; Manasseh G; Becker CD; Terraz S
Int J Hyperthermia; 2015 Jun; 31(4):421-32. PubMed ID: 25753370
[TBL] [Abstract][Full Text] [Related]
20. Increasing the HIFU ablation rate through an MRI-guided sonication strategy using shock waves: feasibility in the in vivo porcine liver.
Ramaekers P; de Greef M; van Breugel JM; Moonen CT; Ries M
Phys Med Biol; 2016 Feb; 61(3):1057-77. PubMed ID: 26757987
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]