These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Radiant energy required for infrared neural stimulation. Tan X; Rajguru S; Young H; Xia N; Stock SR; Xiao X; Richter CP Sci Rep; 2015 Aug; 5():13273. PubMed ID: 26305106 [TBL] [Abstract][Full Text] [Related]
24. Development of a chronically-implanted mouse model for studies of cochlear health and implant function. Colesa DJ; Devare J; Swiderski DL; Beyer LA; Raphael Y; Pfingst BE Hear Res; 2021 May; 404():108216. PubMed ID: 33691255 [TBL] [Abstract][Full Text] [Related]
26. Effect of Fiberoptic Collimation Technique on 808 nm Wavelength Laser Stimulation of Cochlear Neurons. Wang J; Lu J; Tian L Photomed Laser Surg; 2016 Jun; 34(6):252-7. PubMed ID: 26977557 [TBL] [Abstract][Full Text] [Related]
27. Amplitude and pulse rate difference limens for electrical stimulation of the cochlea following graded degeneration of the auditory nerve. Black RC; Steel AC; Clark GM Acta Otolaryngol; 1983; 95(1-2):27-33. PubMed ID: 6687505 [TBL] [Abstract][Full Text] [Related]
28. Acute damage threshold for infrared neural stimulation of the cochlea: functional and histological evaluation. Goyal V; Rajguru S; Matic AI; Stock SR; Richter CP Anat Rec (Hoboken); 2012 Nov; 295(11):1987-99. PubMed ID: 23044730 [TBL] [Abstract][Full Text] [Related]
34. Late electrically-evoked compound action potentials as markers for acute micro-lesions of spiral ganglion neurons. Konerding W; Arenberg JG; Kral A; Baumhoff P Hear Res; 2022 Jan; 413():108057. PubMed ID: 32883545 [TBL] [Abstract][Full Text] [Related]
35. Factors associated with hearing loss in a normal-hearing guinea pig model of Hybrid cochlear implants. Tanaka C; Nguyen-Huynh A; Loera K; Stark G; Reiss L Hear Res; 2014 Oct; 316():82-93. PubMed ID: 25128626 [TBL] [Abstract][Full Text] [Related]
36. Psychoacoustic and electrophysiological electric-acoustic interaction effects in cochlear implant users with ipsilateral residual hearing. Imsiecke M; Büchner A; Lenarz T; Nogueira W Hear Res; 2020 Feb; 386():107873. PubMed ID: 31884220 [TBL] [Abstract][Full Text] [Related]
37. Effects of chronic implantation and long-term stimulation of a cochlear implant in the partial hearing cat model. Fallon JB; Dueck W; Trang EP; Smyth D; Wise AK Hear Res; 2022 Dec; 426():108470. PubMed ID: 35249777 [TBL] [Abstract][Full Text] [Related]
38. Does electrical stimulation of deaf cochleae prevent spiral ganglion degeneration? Li L; Parkins CW; Webster DB Hear Res; 1999 Jul; 133(1-2):27-39. PubMed ID: 10416862 [TBL] [Abstract][Full Text] [Related]
39. Laser stimulation of the auditory nerve. Izzo AD; Richter CP; Jansen ED; Walsh JT Lasers Surg Med; 2006 Sep; 38(8):745-53. PubMed ID: 16871623 [TBL] [Abstract][Full Text] [Related]
40. Optical stimulation of auditory neurons: effects of acute and chronic deafening. Richter CP; Bayon R; Izzo AD; Otting M; Suh E; Goyal S; Hotaling J; Walsh JT Hear Res; 2008 Aug; 242(1-2):42-51. PubMed ID: 18321670 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]