21. Three-dimensional bone response to commercially pure titanium, hydroxyapatite, and calcium-ion-mixing titanium in rabbits. Ichikawa T; Hanawa T; Ukai H; Murakami K Int J Oral Maxillofac Implants; 2000; 15(2):231-8. PubMed ID: 10795455 [TBL] [Abstract][Full Text] [Related]
22. The effect of nanometric surface texture on bone contact to titanium implants in rabbit tibia. Prodanov L; Lamers E; Domanski M; Luttge R; Jansen JA; Walboomers XF Biomaterials; 2013 Apr; 34(12):2920-7. PubMed ID: 23380354 [TBL] [Abstract][Full Text] [Related]
23. Bone-bonding behavior of plasma-sprayed coatings of BioglassR, AW-glass ceramic, and tricalcium phosphate on titanium alloy. Kitsugi T; Nakamura T; Oka M; Senaha Y; Goto T; Shibuya T J Biomed Mater Res; 1996 Feb; 30(2):261-9. PubMed ID: 9019492 [TBL] [Abstract][Full Text] [Related]
24. Histological evaluation of bone formation adjacent to dental implants with a novel apical chamber design: preliminary data in the rabbit model. Meirelles L; Brånemark PI; Albrektsson T; Feng C; Johansson C Clin Implant Dent Relat Res; 2015 Jun; 17(3):453-60. PubMed ID: 24020511 [TBL] [Abstract][Full Text] [Related]
25. Hydroxyapatite-clay bone fixation for loaded implants. Maruyama M J Biomed Mater Res; 1995 Jun; 29(6):683-6. PubMed ID: 7593003 [TBL] [Abstract][Full Text] [Related]
26. Micro-Brillouin scattering measurements in mature and newly formed bone tissue surrounding an implant. Mathieu V; Fukui K; Matsukawa M; Kawabe M; Vayron R; Soffer E; Anagnostou F; Haiat G J Biomech Eng; 2011 Feb; 133(2):021006. PubMed ID: 21280878 [TBL] [Abstract][Full Text] [Related]
27. Histological reaction to titanium alloy and hydroxyapatite particles in the rabbit tibia. Goodman SB; Davidson JA; Fornasier VL Biomaterials; 1993 Aug; 14(10):723-8. PubMed ID: 8218720 [TBL] [Abstract][Full Text] [Related]
28. A removal torque and histomorphometric study of bone tissue reactions to commercially pure titanium and Vitallium implants. Johansson CB; Sennerby L; Albrektsson T Int J Oral Maxillofac Implants; 1991; 6(4):437-41. PubMed ID: 1820312 [TBL] [Abstract][Full Text] [Related]
29. The use of a coin shaped implant for direct in situ measurement of attachment strength for osseointegrating biomaterial surfaces. Rønold HJ; Ellingsen JE Biomaterials; 2002 May; 23(10):2201-9. PubMed ID: 11962661 [TBL] [Abstract][Full Text] [Related]
30. Histomorphometric assessment of the mechanisms for rapid ingrowth of bone to HA/TCP coated implants. Burr DB; Mori S; Boyd RD; Sun TC; Blaha JD; Lane L; Parr J J Biomed Mater Res; 1993 May; 27(5):645-53. PubMed ID: 8314817 [TBL] [Abstract][Full Text] [Related]
31. Cell and matrix reactions at titanium implants in surgically prepared rat tibiae. Masuda T; Salvi GE; Offenbacher S; Felton DA; Cooper LF Int J Oral Maxillofac Implants; 1997; 12(4):472-85. PubMed ID: 9274076 [TBL] [Abstract][Full Text] [Related]
32. Detection of alkaline and acid phosphatases around titanium implants: a light microscopical and histochemical study in rabbits. Piattelli A; Scarano A; Piattelli M Biomaterials; 1995 Nov; 16(17):1333-8. PubMed ID: 8573672 [TBL] [Abstract][Full Text] [Related]
33. Effects on the osseointegration of titanium implants incorporating calcium-magnesium: a resonance frequency and histomorphometric analysis in rabbit tibia. Gehrke SA; Maté Sánchez de Val JE; Fernández Domínguez M; de Aza Moya PN; Gómez Moreno G; Calvo Guirado JL Clin Oral Implants Res; 2018 Jul; 29(7):785-791. PubMed ID: 27381553 [TBL] [Abstract][Full Text] [Related]
34. Bone response to machined and resorbable blast material titanium implants: an experimental study in rabbits. Piattelli M; Scarano A; Paolantonio M; Iezzi G; Petrone G; Piattelli A J Oral Implantol; 2002; 28(1):2-8. PubMed ID: 12498456 [TBL] [Abstract][Full Text] [Related]
35. Hyaluronic Acid-Based Hydrogel Coating Does Not Affect Bone Apposition at the Implant Surface in a Rabbit Model. Boot W; Gawlitta D; Nikkels PGJ; Pouran B; van Rijen MHP; Dhert WJA; Vogely HC Clin Orthop Relat Res; 2017 Jul; 475(7):1911-1919. PubMed ID: 28303535 [TBL] [Abstract][Full Text] [Related]
36. [Experimental study of Ti-24Nb-4Zr-7.9Sn alloy after treated with micro-arc oxidation in vivo]. Liu ZM; Gao B; Zhang LZ Hua Xi Kou Qiang Yi Xue Za Zhi; 2008 Dec; 26(6):595-8. PubMed ID: 19186849 [TBL] [Abstract][Full Text] [Related]
37. Bone response to surface modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology. Larsson C; Thomsen P; Lausmaa J; Rodahl M; Kasemo B; Ericson LE Biomaterials; 1994 Oct; 15(13):1062-74. PubMed ID: 7888577 [TBL] [Abstract][Full Text] [Related]
38. A repeated sampling bone chamber methodology for the evaluation of tissue differentiation and bone adaptation around titanium implants under controlled mechanical conditions. Duyck J; Cooman MD; Puers R; Van Oosterwyck H; Sloten JV; Naert I J Biomech; 2004 Dec; 37(12):1819-22. PubMed ID: 15519589 [TBL] [Abstract][Full Text] [Related]
39. Tissue response to titanium implants in experimental antigen-induced arthritis. Sennerby L; Thomsen P Biomaterials; 1993 May; 14(6):413-22. PubMed ID: 8507787 [TBL] [Abstract][Full Text] [Related]
40. The influence of micro-motion on the tissue differentiation around immediately loaded cylindrical turned titanium implants. Duyck J; Vandamme K; Geris L; Van Oosterwyck H; De Cooman M; Vandersloten J; Puers R; Naert I Arch Oral Biol; 2006 Jan; 51(1):1-9. PubMed ID: 15922992 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]