These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 23511349)

  • 1. Polyurethane does not protect better than polyvinyl cuffed tracheal tubes from microaspirations.
    Bulpa P; Evrard P; Bouhon S; Schryvers F; Jamart J; Michaux I; Dive A; Vander Borght T; Krug B
    Minerva Anestesiol; 2013 May; 79(5):498-503. PubMed ID: 23511349
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of prophylactic effects of polyurethane cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes on ventilator-associated pneumonia.
    Mahmoodpoor A; Peyrovi-far A; Hamishehkar H; Bakhtyiari Z; Mirinezhad MM; Hamidi M; Golzari SE
    Acta Med Iran; 2013 Aug; 51(7):461-6. PubMed ID: 23945890
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: a pilot study.
    Poelaert J; Depuydt P; De Wolf A; Van de Velde S; Herck I; Blot S
    J Thorac Cardiovasc Surg; 2008 Apr; 135(4):771-6. PubMed ID: 18374755
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The value of polyurethane-cuffed endotracheal tubes to reduce microaspiration and intubation-related pneumonia: a systematic review of laboratory and clinical studies.
    Blot SI; Rello J; Koulenti D
    Crit Care; 2016 Jun; 20(1):203. PubMed ID: 27342802
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of an endotracheal tube with polyurethane cuff and subglottic secretion drainage on pneumonia.
    Lorente L; Lecuona M; Jiménez A; Mora ML; Sierra A
    Am J Respir Crit Care Med; 2007 Dec; 176(11):1079-83. PubMed ID: 17872488
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of audible leak
    Kumar P; Abhilasha ; Sharma J; Kaur K; Bharadwaj M; Singh A
    Med Gas Res; 2021; 11(1):6-11. PubMed ID: 33642331
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Randomized intubation with polyurethane or conical cuffs to prevent pneumonia in ventilated patients.
    Philippart F; Gaudry S; Quinquis L; Lau N; Ouanes I; Touati S; Nguyen JC; Branger C; Faibis F; Mastouri M; Forceville X; Abroug F; Ricard JD; Grabar S; Misset B;
    Am J Respir Crit Care Med; 2015 Mar; 191(6):637-45. PubMed ID: 25584431
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modification of Tracheal Cuff Shape and Continuous Cuff Pressure Control to Prevent Microaspiration in an Ex Vivo Pig Tracheal Two-Lung Model.
    Monsel A; Le Corre M; Deransy R; Brisson H; Arbelot C; Lu Q; Golmard JL; Langeron O; Rouby JJ
    Crit Care Med; 2017 Dec; 45(12):e1262-e1269. PubMed ID: 29019852
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A newly developed tracheal tube offering 'pressurised sealing' outperforms currently available tubes in preventing cuff leakage: A benchtop study.
    Spapen HD; Suys E; Diltoer M; Stiers W; Desmet G; Honoré PM
    Eur J Anaesthesiol; 2017 Jul; 34(7):411-416. PubMed ID: 27479464
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of the PneuX System: A Bench Study Comparison With 4 Other Endotracheal Tube Cuffs.
    Chenelle CT; Itagaki T; Fisher DF; Berra L; Kacmarek RM
    Respir Care; 2017 Jan; 62(1):102-112. PubMed ID: 27879379
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of adjusting tracheal tube cuff pressure during deep hypothermic circulatory arrest: a randomised trial.
    Rubes D; Klein AA; Lips M; Rulisek J; Kopecky P; Blaha J; Mlejnsky F; Lindner J; Dohnalova A; Kunstyr J
    Eur J Anaesthesiol; 2014 Sep; 31(9):452-6. PubMed ID: 25077896
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration.
    Young PJ; Pakeerathan S; Blunt MC; Subramanya S
    Crit Care Med; 2006 Mar; 34(3):632-9. PubMed ID: 16505646
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An in vitro study to assess determinant features associated with fluid sealing in the design of endotracheal tube cuffs and exerted tracheal pressures.
    Li Bassi G; Ranzani OT; Marti JD; Giunta V; Luque N; Isetta V; Ferrer M; Farre R; Pimentel GL; Torres A
    Crit Care Med; 2013 Feb; 41(2):518-26. PubMed ID: 23263575
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tapered-cuff Endotracheal Tube Does Not Prevent Early Postoperative Pneumonia Compared with Spherical-cuff Endotracheal Tube after Major Vascular Surgery: A Randomized Controlled Trial.
    Monsel A; Lu Q; Le Corre M; Brisson H; Arbelot C; Vezinet C; Fléron MH; Ibanez-Estève C; Zerimech F; Balduyck M; Dexheimer F; Wang C; Langeron O; Rouby JJ; Bodin L; Deransy R; Garçon P; Douiri H; Khalifa I; Pons A; Gu WJ; Koskas F; Gaudric J;
    Anesthesiology; 2016 May; 124(5):1041-52. PubMed ID: 26872366
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Association among duration of mechanical ventilation, cuff material of endotracheal tube, and postoperative nosocomial pneumonia in cardiac surgical patients: a prospective study.
    Poelaert J; Haentjens P; Blot S
    J Thorac Cardiovasc Surg; 2014 Oct; 148(4):1622-7. PubMed ID: 25127550
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Safe use of cuffed tracheal tubes in children].
    Weiss M; Gerber AC
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2012 Apr; 47(4):232-7. PubMed ID: 22504618
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tracheal Tube Design and Ventilator-Associated Pneumonia.
    Rouzé A; Jaillette E; Poissy J; Préau S; Nseir S
    Respir Care; 2017 Oct; 62(10):1316-1323. PubMed ID: 28720674
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Benchtop study of leakages across the Portex, TaperGuard, and Microcuff endotracheal tubes under simulated clinical conditions.
    Lau AC; Lam SM; Yan WW
    Hong Kong Med J; 2014 Feb; 20(1):7-15. PubMed ID: 23878202
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cuffed tracheal tubes in children: past, present and future.
    Weiss M; Dullenkopf A
    Expert Rev Med Devices; 2007 Jan; 4(1):73-82. PubMed ID: 17187473
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of positive expiratory pressure and type of tracheal cuff on the incidence of aspiration in mechanically ventilated patients in an intensive care unit.
    Lucangelo U; Zin WA; Antonaglia V; Petrucci L; Viviani M; Buscema G; Borelli M; Berlot G
    Crit Care Med; 2008 Feb; 36(2):409-13. PubMed ID: 18007268
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.