BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 23513978)

  • 1. Potentiometric determination of trace amounts of aluminium utilizing polyvinyl chloride membrane and coated platinum sensors based on E-N'-(2-hydroxy-3-methoxybenzylidene) benzohydrazide.
    Tajik S; Taher MA; Sheikhshoaie I
    J AOAC Int; 2013; 96(1):204-11. PubMed ID: 23513978
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design and construction of new potentiometric sensors for determination of Al3+ ion based on (Z)-2-(2-methyl benzylidene)-1-(2,4-dinitrophenyl) hydrazine.
    Mizani F; Salmanzadeh Ardabili S; Ganjaliab MR; Faridbod F; Payehghadr M; Azmoodeh M
    Mater Sci Eng C Mater Biol Appl; 2015 Apr; 49():861-868. PubMed ID: 25687018
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Construction of a new Cu2+ coated wire ion selective electrode based on 2-((2-(2-(2-(2-hydroxy-5-methoxybenzylidene amino)phenyl)disufanyl)phenylimino)methyl)-4-methoxyphenol Schiff base.
    Shokrollahi A; Abbaspour A; Ghaedi M; Haghighi AN; Kianfar AH; Ranjbar M
    Talanta; 2011 Mar; 84(1):34-41. PubMed ID: 21315894
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fabrication of a PVC membrane samarium(III) sensor based on N,N',N"-tris(4-pyridyl)trimesic amide as a selectophore.
    Zamani HA; Naghavi-Reyabbi F; Faridbod F; Mohammadhosseini M; Ganjali MR; Tadjarodi A; Rad M
    Mater Sci Eng C Mater Biol Appl; 2013 Mar; 33(2):870-4. PubMed ID: 25427500
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lanthanum(IlI) PVC membrane electrodes based on 1,3,5-trithiacyclohexane.
    Shamsipur M; Yousefi M; Hosseini M; Ganjali MR
    Anal Chem; 2002 Nov; 74(21):5538-43. PubMed ID: 12433085
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Selective sensing of mercury(II) using PVC-based membranes incorporating recently synthesized 1,3-alternate thiacalix[4]crown ionophore.
    Mahajan RK; Kamal A; Kumar N; Bhalla V; Kumar M
    Environ Sci Pollut Res Int; 2013 May; 20(5):3086-97. PubMed ID: 23054787
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Poly(vinyl) chloride membrane copper-selective electrode based on 1-phenyl-2-(2-hydroxyphenylhydrazo)butane-1,3-dione.
    Kopylovich MN; Mahmudov KT; Pombeiro AJ
    J Hazard Mater; 2011 Feb; 186(2-3):1154-62. PubMed ID: 21177026
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Novel PVC-membrane potentiometric sensors based on a recently synthesized sulfur-containing macrocyclic diamide for Cd2+ ion. Application to flow-injection potentiometry.
    Shamsipur M; Dezaki AS; Akhond M; Sharghi H; Paziraee Z; Alizadeh K
    J Hazard Mater; 2009 Dec; 172(2-3):566-73. PubMed ID: 19640638
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of electrochemical sensors for nano scale Tb(III) ion determination based on pendant macrocyclic ligands.
    Singh AK; Singh P; Banerjee S; Mehtab S
    Anal Chim Acta; 2009 Feb; 633(1):109-18. PubMed ID: 19110124
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Ho(III) potentiometric polymeric membrane sensor based on a new four dentate neutral ion carrier.
    Zamani HA; Zanganeh-Asadabadi A; Rohani M; Zabihi MS; Fadaee J; Ganjali MR; Faridbod F; Meghdadi S
    Mater Sci Eng C Mater Biol Appl; 2013 Mar; 33(2):984-8. PubMed ID: 25427515
    [TBL] [Abstract][Full Text] [Related]  

  • 11. ppt level detection of samarium(III) with a coated graphite sensor based on an antibiotic.
    Ganjali MR; Rezapour M; Pourjavid MR; Haghgoo S
    Anal Sci; 2004 Jul; 20(7):1007-11. PubMed ID: 15293392
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A selective and sensitive carbon composite coated platinum electrode for aluminium determination in pharmaceutical and mineral water samples.
    Abbaspour A; Refahi M; Khalafi-nezhad A; Soltani Rad MN; Behrouz S
    Anal Chim Acta; 2010 Mar; 662(1):76-81. PubMed ID: 20152268
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Synthesis of N'-(1-pyridin-2-ylmethylene)-2-furohydrazide and its application in construction of a highly selective PVC-based membrane sensor for La(III) ions.
    Zamani HA; Ganjali MR; Norouzi P; Adib M; Aceedy M
    Anal Sci; 2006 Jul; 22(7):943-8. PubMed ID: 16837743
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Construction and performance characterization of ion-selective electrodes for potentiometric determination of pseudoephedrine hydrochloride applying batch and flow injection analysis techniques.
    Zayed SI; Issa YM; Hussein A
    Ann Chim; 2006; 96(7-8):421-33. PubMed ID: 16948431
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Construction and characterization of potentiometric sensor for the determination of oxytetracycline hydrochloride.
    Sun XX; Zhang X; Aboul-Enein HY
    Farmaco; 2004 Apr; 59(4):307-14. PubMed ID: 15081348
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Carbon composite-PVC based membrane coated platinum electrode for chromium determination.
    Abbaspour A; Refahi M; Khalafi-Nezhad A; Soltani Rad N; Behrouz S
    J Hazard Mater; 2010 Dec; 184(1-3):20-25. PubMed ID: 20855166
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bismuth (III) PVC membrane ion selective electrodes based on two compounds: acylhydrazone and thiosemicarbazone with 1,3,4-thiadiazole.
    Yan Z; Wang S; Wang H; Wu S
    Mater Sci Eng C Mater Biol Appl; 2013 Jul; 33(5):2562-8. PubMed ID: 23623069
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Carbon nanotube composite coated platinum electrode for detection of Ga(III).
    Abbaspour A; Khoshfetrat SM; Sharghi H; Khalifeh R
    J Hazard Mater; 2011 Jan; 185(1):101-6. PubMed ID: 20980100
    [TBL] [Abstract][Full Text] [Related]  

  • 19. PVC membrane sensor for potentiometric determination of iron (II) in some pharmaceutical formulations based on a new neutral ionophore.
    Abounassif MA; Al-Omar MA; Amr AG; Mostafa GA
    Drug Test Anal; 2011 Jun; 3(6):373-9. PubMed ID: 21698780
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Potentiometric determination of dopamine in pharmaceutical preparations by crown ether-PVC membrane sensors.
    Othman AM; Rizka NM; El-Shahawi MS
    Anal Sci; 2004 Apr; 20(4):651-5. PubMed ID: 15116963
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.