These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
70 related articles for article (PubMed ID: 23514870)
1. Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy. Marcatili S; Pettinato C; Daniels S; Lewis G; Edwards P; Fanti S; Spezi E Phys Med Biol; 2013 Apr; 58(8):2491-508. PubMed ID: 23514870 [TBL] [Abstract][Full Text] [Related]
2. Monte Carlo treatment planning for molecular targeted radiotherapy within the MINERVA system. Lehmann J; Hartmann Siantar C; Wessol DE; Wemple CA; Nigg D; Cogliati J; Daly T; Descalle MA; Flickinger T; Pletcher D; Denardo G Phys Med Biol; 2005 Mar; 50(5):947-58. PubMed ID: 15798267 [TBL] [Abstract][Full Text] [Related]
3. Application of GEANT4 radiation transport toolkit to dose calculations in anthropomorphic phantoms. Rodrigues P; Trindade A; Peralta L; Alves C; Chaves A; Lopes MC Appl Radiat Isot; 2004 Dec; 61(6):1451-61. PubMed ID: 15388147 [TBL] [Abstract][Full Text] [Related]
4. Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries. Chakarova R; Gustafsson M; Bäck A; Drugge N; Palm Å; Lindberg A; Berglund M Radiother Oncol; 2012 Jan; 102(1):102-7. PubMed ID: 21741719 [TBL] [Abstract][Full Text] [Related]
5. COMET-PE: an incident fluence response expansion transport method for radiotherapy calculations. Hayward RM; Rahnema F Phys Med Biol; 2013 May; 58(10):3125-43. PubMed ID: 23603734 [TBL] [Abstract][Full Text] [Related]
6. Validation of the Monte Carlo simulator GATE for indium-111 imaging. Assié K; Gardin I; Véra P; Buvat I Phys Med Biol; 2005 Jul; 50(13):3113-25. PubMed ID: 15972984 [TBL] [Abstract][Full Text] [Related]
7. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms. DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525 [TBL] [Abstract][Full Text] [Related]
8. On the need to revise the arm structure in stylized anthropomorphic phantoms in lateral photon irradiation geometry. Lee C; Lee C; Lee JK Phys Med Biol; 2006 Nov; 51(21):N393-402. PubMed ID: 17047258 [TBL] [Abstract][Full Text] [Related]
9. 3D calculation of absorbed dose for 131I-targeted radiotherapy: a Monte Carlo study. Saeedzadeh E; Sarkar S; Abbaspour Tehrani-Fard A; Ay MR; Khosravi HR; Loudos G Radiat Prot Dosimetry; 2012 Jul; 150(3):298-305. PubMed ID: 22069233 [TBL] [Abstract][Full Text] [Related]
10. Layered mass geometry: a novel technique to overlay seeds and applicators onto patient geometry in Geant4 brachytherapy simulations. Enger SA; Landry G; D'Amours M; Verhaegen F; Beaulieu L; Asai M; Perl J Phys Med Biol; 2012 Oct; 57(19):6269-77. PubMed ID: 22975747 [TBL] [Abstract][Full Text] [Related]
11. Advanced kernel methods vs. Monte Carlo-based dose calculation for high energy photon beams. Fotina I; Winkler P; Künzler T; Reiterer J; Simmat I; Georg D Radiother Oncol; 2009 Dec; 93(3):645-53. PubMed ID: 19926153 [TBL] [Abstract][Full Text] [Related]
12. Experimental verification of a commercial Monte Carlo-based dose calculation module for high-energy photon beams. Künzler T; Fotina I; Stock M; Georg D Phys Med Biol; 2009 Dec; 54(24):7363-77. PubMed ID: 19934489 [TBL] [Abstract][Full Text] [Related]
13. Clinical implementation of full Monte Carlo dose calculation in proton beam therapy. Paganetti H; Jiang H; Parodi K; Slopsema R; Engelsman M Phys Med Biol; 2008 Sep; 53(17):4825-53. PubMed ID: 18701772 [TBL] [Abstract][Full Text] [Related]
14. Patient-specific dosimetry of conventional and intensity modulated radiation therapy using a novel full Monte Carlo phase space reconstruction method from electronic portal images. Jarry G; Verhaegen F Phys Med Biol; 2007 Apr; 52(8):2277-99. PubMed ID: 17404469 [TBL] [Abstract][Full Text] [Related]
15. Dosimetric verification and clinical evaluation of a new commercially available Monte Carlo-based dose algorithm for application in stereotactic body radiation therapy (SBRT) treatment planning. Fragoso M; Wen N; Kumar S; Liu D; Ryu S; Movsas B; Munther A; Chetty IJ Phys Med Biol; 2010 Aug; 55(16):4445-64. PubMed ID: 20668343 [TBL] [Abstract][Full Text] [Related]
16. A preliminary study of in-house Monte Carlo simulations: an integrated Monte Carlo verification system. Mukumoto N; Tsujii K; Saito S; Yasunaga M; Takegawa H; Yamamoto T; Numasaki H; Teshima T Int J Radiat Oncol Biol Phys; 2009 Oct; 75(2):571-9. PubMed ID: 19735883 [TBL] [Abstract][Full Text] [Related]
17. AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE. Panettieri V; Barsoum P; Westermark M; Brualla L; Lax I Radiother Oncol; 2009 Oct; 93(1):94-101. PubMed ID: 19541380 [TBL] [Abstract][Full Text] [Related]
18. VIDA: a voxel-based dosimetry method for targeted radionuclide therapy using Geant4. Kost SD; Dewaraja YK; Abramson RG; Stabin MG Cancer Biother Radiopharm; 2015 Feb; 30(1):16-26. PubMed ID: 25594357 [TBL] [Abstract][Full Text] [Related]
19. A particle track-repeating algorithm for proton beam dose calculation. Li JS; Shahine B; Fourkal E; Ma CM Phys Med Biol; 2005 Mar; 50(5):1001-10. PubMed ID: 15798272 [TBL] [Abstract][Full Text] [Related]
20. Comparison between effective doses for voxel-based and stylized exposure models from photon and electron irradiation. Kramer R; Khoury HJ; Vieira JW Phys Med Biol; 2005 Nov; 50(21):5105-26. PubMed ID: 16237244 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]