88 related articles for article (PubMed ID: 23516956)
1. Model-based needle control in prostate percutaneous procedures.
Maghsoudi A; Jahed M
Proc Inst Mech Eng H; 2013 Jan; 227(1):58-71. PubMed ID: 23516956
[TBL] [Abstract][Full Text] [Related]
2. A framework for predicting three-dimensional prostate deformation in real time.
Jahya A; Herink M; Misra S
Int J Med Robot; 2013 Dec; 9(4):e52-60. PubMed ID: 23495193
[TBL] [Abstract][Full Text] [Related]
3. A biplanar fluoroscopic approach for the measurement, modeling, and simulation of needle and soft-tissue interaction.
Hing JT; Brooks AD; Desai JP
Med Image Anal; 2007 Feb; 11(1):62-78. PubMed ID: 17113339
[TBL] [Abstract][Full Text] [Related]
4. Optimized image-based soft tissue deformation algorithms for visualization of haptic needle insertion.
Fortmeier D; Mastmeyer A; Handels H
Stud Health Technol Inform; 2013; 184():136-40. PubMed ID: 23400145
[TBL] [Abstract][Full Text] [Related]
5. Simulation and experiment of soft-tissue deformation in prostate brachytherapy.
Liang D; Jiang S; Yang Z; Wang X
Proc Inst Mech Eng H; 2016 Jun; 230(6):532-44. PubMed ID: 27129384
[TBL] [Abstract][Full Text] [Related]
6. Quantification of prostate deformation due to needle insertion during TRUS-guided biopsy.
De Silva T; Fenster A; Samarabandu J; Ward AD
Med Image Comput Comput Assist Interv; 2010; 13(Pt 3):213-20. PubMed ID: 20879402
[TBL] [Abstract][Full Text] [Related]
7. Soft tissue modelling with conical springs.
Omar N; Zhong Y; Jazar RN; Subic A; Smith J; Shirinzadeh B
Biomed Mater Eng; 2015; 26 Suppl 1():S207-14. PubMed ID: 26405985
[TBL] [Abstract][Full Text] [Related]
8. Quantification of prostate deformation due to needle insertion during TRUS-guided biopsy: comparison of hand-held and mechanically stabilized systems.
De Silva T; Fenster A; Bax J; Romagnoli C; Izawa J; Samarabandu J; Ward AD
Med Phys; 2011 Mar; 38(3):1718-31. PubMed ID: 21520885
[TBL] [Abstract][Full Text] [Related]
9. Investigating the needle dynamic response during insertion into soft tissue.
Alja'afreh T
Proc Inst Mech Eng H; 2010; 224(4):531-40. PubMed ID: 20476501
[TBL] [Abstract][Full Text] [Related]
10. Force modeling for needle insertion into soft tissue.
Okamura AM; Simone C; O'Leary MD
IEEE Trans Biomed Eng; 2004 Oct; 51(10):1707-16. PubMed ID: 15490818
[TBL] [Abstract][Full Text] [Related]
11. Constrained Point-Based Framework with Efficient Mechanical Interaction for Virtual Surgery.
Si W; Shan J; Liao X; Wang W; Wang Q; Heng PA
Stud Health Technol Inform; 2016; 220():367-74. PubMed ID: 27046607
[TBL] [Abstract][Full Text] [Related]
12. Experimental analysis of robot-assisted needle insertion into porcine liver.
Wang W; Shi Y; Goldenberg AA; Yuan X; Zhang P; He L; Zou Y
Biomed Mater Eng; 2015; 26 Suppl 1():S375-80. PubMed ID: 26406026
[TBL] [Abstract][Full Text] [Related]
13. Prostate biopsy tracking with deformation estimation.
Baumann M; Mozer P; Daanen V; Troccaz J
Med Image Anal; 2012 Apr; 16(3):562-76. PubMed ID: 21705263
[TBL] [Abstract][Full Text] [Related]
14. Needle insertion simulation by arbitrary Lagrangian-Eulerian method.
Yamaguchi S; Satake K; Morikawa S; Shirai Y; Tanaka HT
Stud Health Technol Inform; 2011; 163():710-2. PubMed ID: 21335885
[TBL] [Abstract][Full Text] [Related]
15. Experimental and numerical analysis of soft tissue stiffness measurement using manual indentation device--significance of indentation geometry and soft tissue thickness.
Iivarinen JT; Korhonen RK; Jurvelin JS
Skin Res Technol; 2014 Aug; 20(3):347-54. PubMed ID: 24267492
[TBL] [Abstract][Full Text] [Related]
16. Assessment of image registration accuracy in three-dimensional transrectal ultrasound guided prostate biopsy.
Karnik VV; Fenster A; Bax J; Cool DW; Gardi L; Gyacskov I; Romagnoli C; Ward AD
Med Phys; 2010 Feb; 37(2):802-13. PubMed ID: 20229890
[TBL] [Abstract][Full Text] [Related]
17. Measurement and characterization of soft tissue behavior with surface deformation and force response under large deformations.
Ahn B; Kim J
Med Image Anal; 2010 Apr; 14(2):138-48. PubMed ID: 19948423
[TBL] [Abstract][Full Text] [Related]
18. Quasi-static magnetic resonance elastography at 7 T to measure the effect of pathology before and after fixation on tissue biomechanical properties.
McGrath DM; Foltz WD; Al-Mayah A; Niu CJ; Brock KK
Magn Reson Med; 2012 Jul; 68(1):152-65. PubMed ID: 22213551
[TBL] [Abstract][Full Text] [Related]
19. Modelling liver tissue properties using a non-linear visco-elastic model for surgery simulation.
Schwartz JM; Denninger M; Rancourt D; Moisan C; Laurendeau D
Med Image Anal; 2005 Apr; 9(2):103-12. PubMed ID: 15721226
[TBL] [Abstract][Full Text] [Related]
20. Modeling soft-tissue deformation prior to cutting for surgical simulation: finite element analysis and study of cutting parameters.
Chanthasopeephan T; Desai JP; Lau AC
IEEE Trans Biomed Eng; 2007 Mar; 54(3):349-59. PubMed ID: 17355046
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]