These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 23518860)

  • 1. Appearance of neointima according to stent type and restenotic phase: analysis by optical coherence tomography.
    Goto K; Takebayashi H; Kihara Y; Hagikura A; Fujiwara Y; Kikuta Y; Sato K; Kodama S; Taniguchi M; Hiramatsu S; Haruta S
    EuroIntervention; 2013 Sep; 9(5):601-7. PubMed ID: 23518860
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography.
    Sato K; Costopoulos C; Takebayashi H; Naganuma T; Miyazaki T; Goto K; Yamane H; Hagikura A; Kikuta Y; Taniguchi M; Hiramatsu S; Ito H; Colombo A; Haruta S
    J Cardiol; 2014 Dec; 64(6):488-95. PubMed ID: 24794757
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Difference in neointimal appearance between early and late restenosis after sirolimus-eluting stent implantation assessed by optical coherence tomography.
    Ino Y; Kubo T; Kitabata H; Ishibashi K; Tanimoto T; Matsuo Y; Shimamura K; Shiono Y; Orii M; Komukai K; Yamano T; Yamaguchi T; Hirata K; Tanaka A; Mizukoshi M; Imanishi T; Akasaka T
    Coron Artery Dis; 2013 Mar; 24(2):95-101. PubMed ID: 23363984
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Difference of tissue characteristics between early and very late restenosis lesions after bare-metal stent implantation: an optical coherence tomography study.
    Habara M; Terashima M; Nasu K; Kaneda H; Inoue K; Ito T; Kamikawa S; Kurita T; Tanaka N; Kimura M; Kinoshita Y; Tsuchikane E; Matsuo H; Ueno K; Katoh O; Suzuki T
    Circ Cardiovasc Interv; 2011 Jun; 4(3):232-8. PubMed ID: 21610225
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Analysis of optical coherence tomography of early and very late stent restenosis after drug-eluting stent implantation].
    Liu ZJ; Shi B; Deng CC; Xu GX; Zhao RZ; Shen CY; Wang ZL; Liu HL
    Zhonghua Yi Xue Za Zhi; 2017 Jun; 97(23):1778-1783. PubMed ID: 28647998
    [No Abstract]   [Full Text] [Related]  

  • 6. In-stent restenosis assessed with frequency domain optical coherence tomography shows smooth coronary arterial healing process in second-generation drug-eluting stents.
    Kajiya T; Yamaguchi H; Takaoka J; Fukunaga K; Arima R; Miyamura A; Ninomiya T; Atsuchi N; Atsuchi Y; Terashima M; Kaneda H; Ohishi M
    Singapore Med J; 2019 Jan; 60(1):48-51. PubMed ID: 29632955
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Morphological differences of tissue characteristics between early, late, and very late restenosis lesions after first generation drug-eluting stent implantation: an optical coherence tomography study.
    Habara M; Terashima M; Nasu K; Kaneda H; Yokota D; Ito T; Kurita T; Teramoto T; Kimura M; Kinoshita Y; Tsuchikane E; Asakura Y; Suzuki T
    Eur Heart J Cardiovasc Imaging; 2013 Mar; 14(3):276-84. PubMed ID: 22945378
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Qualitative and quantitative assessment of stent restenosis by optical coherence tomography: comparison between drug-eluting and bare-metal stents.
    Nagoshi R; Shinke T; Otake H; Shite J; Matsumoto D; Kawamori H; Nakagawa M; Kozuki A; Hariki H; Inoue T; Ohsue T; Taniguchi Y; Iwasaki M; Nishio R; Hiranuma N; Konishi A; Kinutani H; Miyoshi N; Takaya T; Yamada S; Yasaka Y; Hayashi T; Yokoyama M; Kato H; Kadotani M; Ohnishi Y; Hirata K
    Circ J; 2013; 77(3):652-60. PubMed ID: 23257388
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography.
    Takano M; Yamamoto M; Inami S; Murakami D; Ohba T; Seino Y; Mizuno K
    J Am Coll Cardiol; 2009 Dec; 55(1):26-32. PubMed ID: 20117359
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In-Stent Restenosis with "Inflammatory" Neointima Following Everolimus-Eluting Stent Implantation.
    Tsuji Y; Koide M; Katsura K; Fujita H; Ishibashi-Ueda H; Otsuka F
    Int Heart J; 2018 Sep; 59(5):1142-1145. PubMed ID: 30012926
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Different Neoatherosclerosis Patterns in Drug-Eluting- and Bare-Metal Stent Restenosis - Optical Coherence Tomography Study.
    Nakamura D; Yasumura K; Nakamura H; Matsuhiro Y; Yasumoto K; Tanaka A; Matsunaga-Lee Y; Yano M; Yamato M; Egami Y; Shutta R; Sakata Y; Tanouchi J; Nishino M
    Circ J; 2019 Jan; 83(2):313-319. PubMed ID: 30487370
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optical coherence tomography evaluation of in-stent restenotic lesions with visible microvessels.
    Kim BK; Kim JS; Shin DH; Ko YG; Choi D; Jang Y; Hong MK
    J Invasive Cardiol; 2012 Mar; 24(3):116-20. PubMed ID: 22388303
    [TBL] [Abstract][Full Text] [Related]  

  • 13. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).
    Ormiston J; Webster M; Stewart J; Vrolix M; Whitbourn R; Donohoe D; Knape C; Lansky A; Attizzani GF; Fitzgerald P; Kandzari DE; Wijns W
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1026-34. PubMed ID: 24055443
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Difference of Tissue Characteristics Between Early and Late Restenosis After Second-Generation Drug-Eluting Stents Implantation - An Optical Coherence Tomography Study.
    Jinnouchi H; Kuramitsu S; Shinozaki T; Tomoi Y; Hiromasa T; Kobayashi Y; Domei T; Soga Y; Hyodo M; Shirai S; Ando K
    Circ J; 2017 Mar; 81(4):450-457. PubMed ID: 28132981
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of incidence and time course of neoatherosclerosis between bare metal stents and drug-eluting stents using optical coherence tomography.
    Yonetsu T; Kim JS; Kato K; Kim SJ; Xing L; Yeh RW; Sakhuja R; McNulty I; Lee H; Zhang S; Uemura S; Yu B; Kakuta T; Jang IK
    Am J Cardiol; 2012 Oct; 110(7):933-9. PubMed ID: 22727183
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optical coherence tomography patterns of stent restenosis.
    Gonzalo N; Serruys PW; Okamura T; van Beusekom HM; Garcia-Garcia HM; van Soest G; van der Giessen W; Regar E
    Am Heart J; 2009 Aug; 158(2):284-93. PubMed ID: 19619707
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Visualization of intimal proliferation of drug-eluting stent and bare mental stent by use of optical coherence tomography].
    Chen BX; Ma FY; Luo W; Xie WL; Sun SH; Guo XM; Wang F; Zhao XZ; Chu XW
    Zhonghua Yi Xue Za Zhi; 2006 Apr; 86(16):1102-6. PubMed ID: 16796834
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.
    Kim JS; Jang IK; Fan C; Kim TH; Kim JS; Park SM; Choi EY; Lee SH; Ko YG; Choi D; Hong MK; Jang Y
    JACC Cardiovasc Interv; 2009 Dec; 2(12):1240-7. PubMed ID: 20129551
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents.
    Guagliumi G; Musumeci G; Sirbu V; Bezerra HG; Suzuki N; Fiocca L; Matiashvili A; Lortkipanidze N; Trivisonno A; Valsecchi O; Biondi-Zoccai G; Costa MA;
    JACC Cardiovasc Interv; 2010 May; 3(5):531-9. PubMed ID: 20488410
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Histopathology of clinical coronary restenosis in drug-eluting versus bare metal stents.
    Chieffo A; Foglieni C; Nodari RL; Briguori C; Sangiorgi G; Latib A; Montorfano M; Airoldi F; Michev I; Carlino M; Colombo A; Maseri A
    Am J Cardiol; 2009 Dec; 104(12):1660-7. PubMed ID: 19962471
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.