These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 2352007)

  • 21. The effect of sensor malpositioning on pulse oximeter accuracy during hypoxemia.
    Barker SJ; Hyatt J; Shah NK; Kao YJ
    Anesthesiology; 1993 Aug; 79(2):248-54. PubMed ID: 8342837
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Saturation by pulse oximetry: comparison of the results obtained by instruments of different brands.
    Thilo EH; Andersen D; Wasserstein ML; Schmidt J; Luckey D
    J Pediatr; 1993 Apr; 122(4):620-6. PubMed ID: 7681875
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension.
    Kohyama T; Moriyama K; Kanai R; Kotani M; Uzawa K; Satoh T; Yorozu T
    PLoS One; 2015; 10(5):e0126979. PubMed ID: 25978517
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Skin reflectance pulse oximetry: in vivo measurements from the forearm and calf.
    Mendelson Y; McGinn MJ
    J Clin Monit; 1991 Jan; 7(1):7-12. PubMed ID: 1999702
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Pulse oximetry in severe anaemia.
    Ramsing T; Rosenberg J
    Intensive Care Med; 1992; 18(2):125-6. PubMed ID: 1613193
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Errors in 14 pulse oximeters during profound hypoxia.
    Severinghaus JW; Naifeh KH; Koh SO
    J Clin Monit; 1989 Apr; 5(2):72-81. PubMed ID: 2723709
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A multicentre prospective observational study comparing arterial blood gas values to those obtained by pulse oximeters used in adult patients attending Australian and New Zealand hospitals.
    Pilcher J; Ploen L; McKinstry S; Bardsley G; Chien J; Howard L; Lee S; Beckert L; Swanney M; Weatherall M; Beasley R
    BMC Pulm Med; 2020 Jan; 20(1):7. PubMed ID: 31918697
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults.
    Jensen LA; Onyskiw JE; Prasad NG
    Heart Lung; 1998; 27(6):387-408. PubMed ID: 9835670
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Transmission pulse oximetry in the fetal lamb: is there a universal calibration?
    Nijland R; Jongsma HW; Crevels J; Menssen JJ; Nijhuis JG; Oeseburg B
    Pediatr Res; 1996 Mar; 39(3):464-9. PubMed ID: 8929867
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy of pulse oximetry to estimate HbO2 fraction of total Hb during exercise.
    Powers SK; Dodd S; Freeman J; Ayers GD; Samson H; McKnight T
    J Appl Physiol (1985); 1989 Jul; 67(1):300-4. PubMed ID: 2759956
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Bias and precision of pulse oximeters and arterial oximeters.
    Nickerson BG; Sarkisian C; Tremper K
    Chest; 1988 Mar; 93(3):515-7. PubMed ID: 3342658
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of peripheral perfusion on accuracy of pulse oximetry in children.
    Villanueva R; Bell C; Kain ZN; Colingo KA
    J Clin Anesth; 1999 Jun; 11(4):317-22. PubMed ID: 10470634
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Accuracy and precision of fourteen pulse oximeters.
    Hannhart B; Haberer JP; Saunier C; Laxenaire MC
    Eur Respir J; 1991 Jan; 4(1):115-9. PubMed ID: 2026231
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Accuracy of two pulse oximeters during maximal cycling exercise.
    Wood RJ; Gore CJ; Hahn AG; Norton KI; Scroop GC; Campbell DP; Watson DB; Emonson DL
    Aust J Sci Med Sport; 1997 Jun; 29(2):47-50. PubMed ID: 9242977
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Potential errors in pulse oximetry. II. Effects of changes in saturation and signal quality.
    Webb RK; Ralston AC; Runciman WB
    Anaesthesia; 1991 Mar; 46(3):207-12. PubMed ID: 2014899
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Accuracy of a pulse oximeter during hypoxia].
    Tachibana C; Fukada T; Hasegawa R; Satoh K; Furuya Y; Ohe Y
    Masui; 1996 Apr; 45(4):479-82. PubMed ID: 8725606
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Arteriovenous oximeter for O2 content difference, O2 saturations, and hemoglobin content.
    Suga H; Futaki S; Ohgoshi Y; Yaku H; Goto Y
    Am J Physiol; 1989 Nov; 257(5 Pt 2):H1712-6. PubMed ID: 2589522
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Precision and accuracy of "a pocket" pulse oximeter in Mexico City].
    Torre-Bouscoulet L; Chávez-Plascencia E; Vázquez-García JC; Pérez-Padilla R
    Rev Invest Clin; 2006; 58(1):28-33. PubMed ID: 16789596
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A prototype device for standardized calibration of pulse oximeters II.
    Hornberger Ch; Knoop P; Matz H; Dörries F; Konecny E; Gehring H; Otten J; Bonk R; Frankenberger H; Wouters P; Gil-Rodriguez J; Ponz L; Avgerinos J; Karoutis A; Ikiades A; Weininger S
    J Clin Monit Comput; 2002; 17(3-4):203-9. PubMed ID: 12455737
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Accuracy of pulse oximetry during arterial oxyhemoglobin desaturation in dogs.
    Sendak MJ; Harris AP; Donham RT
    Anesthesiology; 1988 Jan; 68(1):111-4. PubMed ID: 3337361
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.