BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

246 related articles for article (PubMed ID: 23520359)

  • 1. Co-blasting of titanium surfaces with an abrasive and hydroxyapatite to produce bioactive coatings: substrate and coating characterisation.
    Dunne CF; Twomey B; O'Neill L; Stanton KT
    J Biomater Appl; 2014 Jan; 28(5):767-78. PubMed ID: 23520359
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hydroxyapatite and fluorapatite coatings on dental screws: effects of blast coating process and biological response.
    Dunne CF; Twomey B; Kelly C; Simpson JC; Stanton KT
    J Mater Sci Mater Med; 2015 Jan; 26(1):5347. PubMed ID: 25578701
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of substrate metal alloy type on the properties of hydroxyapatite coatings deposited using a novel ambient temperature deposition technique.
    Barry JN; Cowley A; McNally PJ; Dowling DP
    J Biomed Mater Res A; 2014 Mar; 102(3):871-9. PubMed ID: 23589437
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bond strength, compositional, and structural properties of hydroxyapatite coating on Ti, ZrO2-coated Ti, and TPS-coated Ti substrate.
    Yang Y; Ong JL
    J Biomed Mater Res A; 2003 Mar; 64(3):509-16. PubMed ID: 12579565
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of fluorapatite on the properties of thermally sprayed hydroxyapatite coatings.
    Bhadang KA; Gross KA
    Biomaterials; 2004 Sep; 25(20):4935-45. PubMed ID: 15109854
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Implant surface modification using laser guided coatings: in vitro comparison of mechanical properties.
    Vasanthan A; Kim H; Drukteinis S; Lacefield W
    J Prosthodont; 2008 Jul; 17(5):357-64. PubMed ID: 18544138
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vitro and in vivo bioactivity of CoBlast hydroxyapatite coating and the effect of impaction on its osteoconductivity.
    Tan F; Naciri M; Dowling D; Al-Rubeai M
    Biotechnol Adv; 2012; 30(1):352-62. PubMed ID: 21801828
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biological responses to hydroxyapatite surfaces deposited via a co-incident microblasting technique.
    O'Hare P; Meenan BJ; Burke GA; Byrne G; Dowling D; Hunt JA
    Biomaterials; 2010 Jan; 31(3):515-22. PubMed ID: 19864018
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Plasma-sprayed hydroxyapatite+titania composite bond coat for hydroxyapatite coating on titanium substrate.
    Lu YP; Li MS; Li ST; Wang ZG; Zhu RF
    Biomaterials; 2004 Aug; 25(18):4393-403. PubMed ID: 15046930
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Processing and in vitro behavior of hydroxyapatite coatings prepared by electrostatic spray assisted vapor deposition method.
    Hou X; Choy KL; Leach SE
    J Biomed Mater Res A; 2007 Dec; 83(3):683-91. PubMed ID: 17530629
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Structural, microstructural, and residual stress investigations of plasma-sprayed hydroxyapatite on Ti-6Al-4 V.
    Carradó A
    ACS Appl Mater Interfaces; 2010 Feb; 2(2):561-5. PubMed ID: 20356205
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Functionally gradient bonelike hydroxyapatite coating on a titanium metal substrate created by a discharging method in HBSS without organic molecules.
    Shibata Y; Takashima H; Yamamoto H; Miyazaki T
    Int J Oral Maxillofac Implants; 2004; 19(2):177-83. PubMed ID: 15101587
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surface characteristics and dissolution behavior of plasma-sprayed hydroxyapatite coating.
    Sun L; Berndt CC; Khor KA; Cheang HN; Gross KA
    J Biomed Mater Res; 2002 Nov; 62(2):228-36. PubMed ID: 12209943
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electrohydrodynamic coating of metal with nano-sized hydroxyapatite.
    Li X; Huang J; Ahmad Z; Edirisinghe M
    Biomed Mater Eng; 2007; 17(6):335-46. PubMed ID: 18032815
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparative physico-chemical study of chlorapatite and hydroxyapatite: from powders to plasma sprayed thin coatings.
    Demnati I; Grossin D; Combes C; Parco M; Braceras I; Rey C
    Biomed Mater; 2012 Oct; 7(5):054101. PubMed ID: 22971953
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Novel sphene coatings on Ti-6Al-4V for orthopedic implants using sol-gel method.
    Wu C; Ramaswamy Y; Gale D; Yang W; Xiao K; Zhang L; Yin Y; Zreiqat H
    Acta Biomater; 2008 May; 4(3):569-76. PubMed ID: 18182336
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Compositionally graded hydroxyapatite/tricalcium phosphate coating on Ti by laser and induction plasma.
    Roy M; Balla VK; Bandyopadhyay A; Bose S
    Acta Biomater; 2011 Feb; 7(2):866-73. PubMed ID: 20854939
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Adherent apatite coating on titanium substrate using chemical deposition.
    Rohanizadeh R; LeGeros RZ; Harsono M; Bendavid A
    J Biomed Mater Res A; 2005 Mar; 72(4):428-38. PubMed ID: 15666365
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characteristics of hydroxyapatite coated titanium porous coatings on Ti-6Al-4V substrates by plasma sprayed method.
    Yang CY; Chen CR; Chang E; Lee TM
    J Biomed Mater Res B Appl Biomater; 2007 Aug; 82(2):450-9. PubMed ID: 17245748
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bone response adjacent to calcium phosphate electrostatic spray deposition coated implants: an experimental study in goats.
    Manders PJ; Wolke JG; Jansen JA
    Clin Oral Implants Res; 2006 Oct; 17(5):548-53. PubMed ID: 16958695
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.