These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 23521496)

  • 21. Improving isothermal DNA amplification speed for the rapid detection of Mycobacterium tuberculosis.
    Motré A; Kong R; Li Y
    J Microbiol Methods; 2011 Feb; 84(2):343-5. PubMed ID: 21167881
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Loop region-specific oligonucleotide probes for loop-mediated isothermal amplification-enzyme-linked immunosorbent assay truly minimize the instrument needed for detection process.
    Ravan H; Yazdanparast R
    Anal Biochem; 2013 Aug; 439(2):102-8. PubMed ID: 23624347
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The development of DNA-based quartz crystal microbalance integrated with isothermal DNA amplification system for human papillomavirus type 58 detection.
    Prakrankamanant P; Leelayuwat C; Promptmas C; Limpaiboon T; Wanram S; Prasongdee P; Pientong C; Daduang J; Jearanaikoon P
    Biosens Bioelectron; 2013 Feb; 40(1):252-7. PubMed ID: 22959017
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A novel method for the purification of DNA by capturing nucleic acid and magnesium complexes on non-woven fabric filters under alkaline conditions for the gene diagnosis of tuberculosis by loop-mediated isothermal amplification (LAMP).
    Fukasawa T; Oda N; Wada Y; Tamaru A; Fukushima Y; Nakajima C; Suzuki Y
    Jpn J Infect Dis; 2010 Jul; 63(4):246-50. PubMed ID: 20657063
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Loop-mediated isothermal amplification integrated on microfluidic chips for point-of-care quantitative detection of pathogens.
    Fang X; Liu Y; Kong J; Jiang X
    Anal Chem; 2010 Apr; 82(7):3002-6. PubMed ID: 20218572
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An integrated rotary microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip based detection for point-of-care pathogen diagnostics.
    Park BH; Oh SJ; Jung JH; Choi G; Seo JH; Kim DH; Lee EY; Seo TS
    Biosens Bioelectron; 2017 May; 91():334-340. PubMed ID: 28043075
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A multiplexed nucleic acid microsystem for point-of-care detection of HIV co-infection with MTB and PCP.
    Xu L; Kong J
    Talanta; 2013 Dec; 117():532-5. PubMed ID: 24209377
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A digital microfluidic system for loop-mediated isothermal amplification and sequence specific pathogen detection.
    Wan L; Chen T; Gao J; Dong C; Wong AH; Jia Y; Mak PI; Deng CX; Martins RP
    Sci Rep; 2017 Nov; 7(1):14586. PubMed ID: 29109452
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Direct detection of Mycobacterium tuberculosis in clinical samples by a dry methyl green loop-mediated isothermal amplification (LAMP) method.
    Thapa J; Maharjan B; Malla M; Fukushima Y; Poudel A; Pandey BD; Hyashida K; Gordon SV; Nakajima C; Suzuki Y
    Tuberculosis (Edinb); 2019 Jul; 117():1-6. PubMed ID: 31378262
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A microfluidic chip capable of generating and trapping emulsion droplets for digital loop-mediated isothermal amplification analysis.
    Ma YD; Luo K; Chang WH; Lee GB
    Lab Chip; 2018 Jan; 18(2):296-303. PubMed ID: 29188245
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Detection of Mycobacterium tuberculosis by using loop-mediated isothermal amplification combined with a lateral flow dipstick in clinical samples.
    Kaewphinit T; Arunrut N; Kiatpathomchai W; Santiwatanakul S; Jaratsing P; Chansiri K
    Biomed Res Int; 2013; 2013():926230. PubMed ID: 23555102
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Detection of Bacillus anthracis from spores and cells by loop-mediated isothermal amplification without sample preparation.
    Dugan L; Bearinger J; Hinckley A; Strout C; Souza B
    J Microbiol Methods; 2012 Sep; 90(3):280-4. PubMed ID: 22677603
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Attomolar quantitation of Mycobacterium tuberculosis by asymmetric helicase-dependent isothermal DNA-amplification and electrochemical detection.
    Barreda-García S; González-Álvarez MJ; de-Los-Santos-Álvarez N; Palacios-Gutiérrez JJ; Miranda-Ordieres AJ; Lobo-Castañón MJ
    Biosens Bioelectron; 2015 Jun; 68():122-128. PubMed ID: 25562738
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Detection of phytoplasma by loop-mediated isothermal amplification of DNA (LAMP).
    Obura E; Masiga D; Wachira F; Gurja B; Khan ZR
    J Microbiol Methods; 2011 Feb; 84(2):312-6. PubMed ID: 21185882
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Droplet-based microfluidic systems for high-throughput single DNA molecule isothermal amplification and analysis.
    Mazutis L; Araghi AF; Miller OJ; Baret JC; Frenz L; Janoshazi A; Taly V; Miller BJ; Hutchison JB; Link D; Griffiths AD; Ryckelynck M
    Anal Chem; 2009 Jun; 81(12):4813-21. PubMed ID: 19518143
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Rapid detection of varicella-zoster virus infection by a loop-mediated isothermal amplification method.
    Okamoto S; Yoshikawa T; Ihira M; Suzuki K; Shimokata K; Nishiyama Y; Asano Y
    J Med Virol; 2004 Dec; 74(4):677-82. PubMed ID: 15484264
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Sensitive and rapid detection of cholera toxin-producing Vibrio cholerae using loop-mediated isothermal amplification.
    Yamazaki W
    Methods Mol Biol; 2011; 739():13-22. PubMed ID: 21567314
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Graphene-based electrochemical genosensor incorporated loop-mediated isothermal amplification for rapid on-site detection of Mycobacterium tuberculosis.
    Jaroenram W; Kampeera J; Arunrut N; Karuwan C; Sappat A; Khumwan P; Jaitrong S; Boonnak K; Prammananan T; Chaiprasert A; Tuantranont A; Kiatpathomchai W
    J Pharm Biomed Anal; 2020 Jul; 186():113333. PubMed ID: 32402994
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Loop-mediated isothermal amplification (LAMP) for the direct detection of human pulmonary infections with environmental (nontuberculosis) mycobacteria.
    Adhikari BR; Pandey BD; Ghimire P; Shrestha B; Khadka M; Yoda T; Suzuki Y
    Jpn J Infect Dis; 2009 May; 62(3):212-4. PubMed ID: 19468184
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A polymer microfluidic chip for quantitative detection of multiple water- and foodborne pathogens using real-time fluorogenic loop-mediated isothermal amplification.
    Tourlousse DM; Ahmad F; Stedtfeld RD; Seyrig G; Tiedje JM; Hashsham SA
    Biomed Microdevices; 2012 Aug; 14(4):769-78. PubMed ID: 22566273
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.