These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

544 related articles for article (PubMed ID: 23523938)

  • 21. Magnesium alloys as implant materials--principles of property design for Mg-RE alloys.
    Hort N; Huang Y; Fechner D; Störmer M; Blawert C; Witte F; Vogt C; Drücker H; Willumeit R; Kainer KU; Feyerabend F
    Acta Biomater; 2010 May; 6(5):1714-25. PubMed ID: 19788945
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Development and properties of Ti-In binary alloys as dental biomaterials.
    Wang QY; Wang YB; Lin JP; Zheng YF
    Mater Sci Eng C Mater Biol Appl; 2013 Apr; 33(3):1601-6. PubMed ID: 23827613
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Microstructure, mechanical properties, in vitro degradation and cytotoxicity evaluations of Mg-1.5Y-1.2Zn-0.44Zr alloys for biodegradable metallic implants.
    Fan J; Qiu X; Niu X; Tian Z; Sun W; Liu X; Li Y; Li W; Meng J
    Mater Sci Eng C Mater Biol Appl; 2013 May; 33(4):2345-52. PubMed ID: 23498268
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Influence of ageing treatment on microstructure, mechanical and bio-corrosion properties of Mg-Dy alloys.
    Yang L; Huang Y; Feyerabend F; Willumeit R; Kainer KU; Hort N
    J Mech Behav Biomed Mater; 2012 Sep; 13():36-44. PubMed ID: 22842274
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Enhancement of the electrochemical behaviour and biological performance of Ti-25Ta-5Zr alloy by thermo-mechanical processing.
    Cimpean A; Vasilescu E; Drob P; Cinca I; Vasilescu C; Anastasescu M; Mitran V; Drob SI
    Mater Sci Eng C Mater Biol Appl; 2014 May; 38():127-42. PubMed ID: 24656361
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Investigation on the microstructure, mechanical properties, in vitro degradation behavior and biocompatibility of newly developed Zn-0.8%Li-(Mg, Ag) alloys for guided bone regeneration.
    Zhang Y; Yan Y; Xu X; Lu Y; Chen L; Li D; Dai Y; Kang Y; Yu K
    Mater Sci Eng C Mater Biol Appl; 2019 Jun; 99():1021-1034. PubMed ID: 30889634
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of the existing form of Cu element on the mechanical properties, bio-corrosion and antibacterial properties of Ti-Cu alloys for biomedical application.
    Zhang E; Wang X; Chen M; Hou B
    Mater Sci Eng C Mater Biol Appl; 2016 Dec; 69():1210-21. PubMed ID: 27612819
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The development of binary Mg-Ca alloys for use as biodegradable materials within bone.
    Li Z; Gu X; Lou S; Zheng Y
    Biomaterials; 2008 Apr; 29(10):1329-44. PubMed ID: 18191191
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Optimization of mechanical properties, biocorrosion properties and antibacterial properties of as-cast Ti-Cu alloys.
    Zhang E; Ren J; Li S; Yang L; Qin G
    Biomed Mater; 2016 Oct; 11(6):065001. PubMed ID: 27767022
    [TBL] [Abstract][Full Text] [Related]  

  • 30. On the biodegradability, mechanical behavior, and cytocompatibility of amorphous Mg72 Zn23 Ca5 and crystalline Mg70 Zn23 Ca5 Pd2 alloys as temporary implant materials.
    Pellicer E; González S; Blanquer A; Suriñach S; Baró MD; Barrios L; Ibáñez E; Nogués C; Sort J
    J Biomed Mater Res A; 2013 Feb; 101(2):502-17. PubMed ID: 22927340
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Microstructure, hardness, corrosion resistance and porcelain shear bond strength comparison between cast and hot pressed CoCrMo alloy for metal-ceramic dental restorations.
    Henriques B; Soares D; Silva FS
    J Mech Behav Biomed Mater; 2012 Aug; 12():83-92. PubMed ID: 22659369
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Superelasticity, corrosion resistance and biocompatibility of the Ti-19Zr-10Nb-1Fe alloy.
    Xue P; Li Y; Li K; Zhang D; Zhou C
    Mater Sci Eng C Mater Biol Appl; 2015 May; 50():179-86. PubMed ID: 25746260
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Surface microstructure and in vitro analysis of nanostructured akermanite (Ca2MgSi2O7) coating on biodegradable magnesium alloy for biomedical applications.
    Razavi M; Fathi M; Savabi O; Hashemi Beni B; Vashaee D; Tayebi L
    Colloids Surf B Biointerfaces; 2014 May; 117():432-40. PubMed ID: 24721316
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Fabrication of biodegradable Zn-Al-Mg alloy: Mechanical properties, corrosion behavior, cytotoxicity and antibacterial activities.
    Bakhsheshi-Rad HR; Hamzah E; Low HT; Kasiri-Asgarani M; Farahany S; Akbari E; Cho MH
    Mater Sci Eng C Mater Biol Appl; 2017 Apr; 73():215-219. PubMed ID: 28183601
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Mechanical properties, corrosion, and biocompatibility of Mg-Zr-Sr-Dy alloys for biodegradable implant applications.
    Ding Y; Lin J; Wen C; Zhang D; Li Y
    J Biomed Mater Res B Appl Biomater; 2018 Aug; 106(6):2425-2434. PubMed ID: 29193657
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Degradable metallic biomaterials: design and development of Fe-Mn alloys for stents.
    Hermawan H; Dubé D; Mantovani D
    J Biomed Mater Res A; 2010 Apr; 93(1):1-11. PubMed ID: 19437432
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Investigation of the mechanical and degradation properties of Mg-Sr and Mg-Zn-Sr alloys for use as potential biodegradable implant materials.
    Brar HS; Wong J; Manuel MV
    J Mech Behav Biomed Mater; 2012 Mar; 7():87-95. PubMed ID: 22340688
    [TBL] [Abstract][Full Text] [Related]  

  • 38. New Zr-25Ti-xMo alloys for dental implant application: Properties characterization and surface analysis.
    Wei C; Luo L; Wu Z; Zhang J; Su S; Zhan Y
    J Mech Behav Biomed Mater; 2020 Nov; 111():104017. PubMed ID: 32818772
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Microstructure, mechanical property, corrosion behavior, and in vitro biocompatibility of Zr-Mo alloys.
    Zhou FY; Wang BL; Qiu KJ; Li L; Lin JP; Li HF; Zheng YF
    J Biomed Mater Res B Appl Biomater; 2013 Feb; 101(2):237-46. PubMed ID: 23143798
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Microstructural, mechanical and corrosion characteristics of heat-treated Mg-1.2Zn-0.5Ca (wt%) alloy for use as resorbable bone fixation material.
    Ibrahim H; Klarner AD; Poorganji B; Dean D; Luo AA; Elahinia M
    J Mech Behav Biomed Mater; 2017 May; 69():203-212. PubMed ID: 28088072
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 28.