BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

284 related articles for article (PubMed ID: 23524501)

  • 1. Changes in hemodynamics after placing intracranial stents.
    Tanemura H; Ishida F; Miura Y; Umeda Y; Fukazawa K; Suzuki H; Sakaida H; Matsushima S; Shimosaka S; Taki W
    Neurol Med Chir (Tokyo); 2013; 53(3):171-8. PubMed ID: 23524501
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms.
    Xiang J; Damiano RJ; Lin N; Snyder KV; Siddiqui AH; Levy EI; Meng H
    J Neurosurg; 2015 Oct; 123(4):832-40. PubMed ID: 26090829
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessing the Hemodynamics in Residual Cavities of Intracranial Aneurysm after Coil Embolization with Combined Computational Flow Dynamics and Silent Magnetic Resonance Angiography.
    Suzuki T; Genkai N; Nomura T; Abe H
    J Stroke Cerebrovasc Dis; 2020 Dec; 29(12):105290. PubMed ID: 32992205
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Flow diverter effect of LVIS stent on cerebral aneurysm hemodynamics: a comparison with Enterprise stents and the Pipeline device.
    Wang C; Tian Z; Liu J; Jing L; Paliwal N; Wang S; Zhang Y; Xiang J; Siddiqui AH; Meng H; Yang X
    J Transl Med; 2016 Jul; 14(1):199. PubMed ID: 27370946
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction.
    Shobayashi Y; Tateshima S; Kakizaki R; Sudo R; Tanishita K; Viñuela F
    J Neurointerv Surg; 2013 Nov; 5 Suppl 3():iii38-42. PubMed ID: 23048176
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Alteration of intraaneurysmal hemodynamics by placement of a self-expandable stent. Laboratory investigation.
    Tateshima S; Tanishita K; Hakata Y; Tanoue SY; Viñuela F
    J Neurosurg; 2009 Jul; 111(1):22-7. PubMed ID: 19267529
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The hemodynamic alterations induced by the vascular angular deformation in stent-assisted coiling of bifurcation aneurysms.
    Jeong W; Han MH; Rhee K
    Comput Biol Med; 2014 Oct; 53():1-8. PubMed ID: 25089357
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Alteration of intra-aneurysmal hemodynamics for flow diversion using enterprise and vision stents.
    Tremmel M; Xiang J; Natarajan SK; Hopkins LN; Siddiqui AH; Levy EI; Meng H
    World Neurosurg; 2010; 74(2-3):306-15. PubMed ID: 21197155
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Repression of wall shear stress inside cerebral aneurysm at bifurcation of anterior cerebral artery by stents.
    Yamaguchi R; Tanaka G; Liu H; Ujiie H
    Heart Vessels; 2016 Apr; 31(4):622-7. PubMed ID: 25813684
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hemodynamic changes due to stent placement in bifurcating intracranial aneurysms.
    Cantón G; Levy DI; Lasheras JC
    J Neurosurg; 2005 Jul; 103(1):146-55. PubMed ID: 16121985
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hemodynamic Effect of Flow Diverter and Coils in Treatment of Large and Giant Intracranial Aneurysms.
    Jing L; Zhong J; Liu J; Yang X; Paliwal N; Meng H; Wang S; Zhang Y
    World Neurosurg; 2016 May; 89():199-207. PubMed ID: 26852712
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization.
    Liu J; Jing L; Wang C; Paliwal N; Wang S; Zhang Y; Xiang J; Siddiqui AH; Meng H; Yang X
    J Neurointerv Surg; 2016 Nov; 8(11):1140-1147. PubMed ID: 26610731
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Computational study for the effects of coil configuration on blood flow characteristics in coil-embolized cerebral aneurysm.
    Otani T; Ii S; Shigematsu T; Fujinaka T; Hirata M; Ozaki T; Wada S
    Med Biol Eng Comput; 2017 May; 55(5):697-710. PubMed ID: 27444298
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison among different high porosity stent configurations: hemodynamic effects of treatment in a large cerebral aneurysm.
    Roszelle BN; Nair P; Gonzalez LF; Haithem Babiker M; Ryan J; Frakes D
    J Biomech Eng; 2014 Feb; 136(2):021013. PubMed ID: 24337100
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hemodynamic differences by increasing low profile visualized intraluminal support (LVIS) stent local compaction across intracranial aneurysm orifice.
    Tian Z; Zhang M; Li G; Jin R; Leng X; Zhang Y; Wang K; Zhang Y; Yang X; Xiang J; Liu J
    Interv Neuroradiol; 2020 Oct; 26(5):557-565. PubMed ID: 32830566
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hemodynamic effects of intracranial aneurysms from stent-induced straightening of parent vessels by stent-assisted coiling embolization.
    Leng X; Wan H; Li G; Jiang Y; Huang L; Siddiqui AH; Zhang X; Xiang J
    Interv Neuroradiol; 2021 Apr; 27(2):181-190. PubMed ID: 33641496
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up.
    Biondi A; Janardhan V; Katz JM; Salvaggio K; Riina HA; Gobin YP
    Neurosurgery; 2007 Sep; 61(3):460-8; discussion 468-9. PubMed ID: 17881956
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms.
    Cantón G; Levy DI; Lasheras JC; Nelson PK
    J Neurosurg; 2005 Nov; 103(5):891-902. PubMed ID: 16304994
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The adverse effects of flow-diverter stent-like devices on the flow pattern of saccular intracranial aneurysm models: computational fluid dynamics study.
    Hassan T; Ahmed YM; Hassan AA
    Acta Neurochir (Wien); 2011 Aug; 153(8):1633-40. PubMed ID: 21647821
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Successful Retreatment of Recurrent Intracranial Vertebral Artery Dissecting Aneurysms After Stent-Assisted Coil Embolization: A Self-Controlled Hemodynamic Analysis.
    Liu J; Jing L; Zhang Y; Song Y; Wang Y; Li C; Wang Y; Mu S; Paliwal N; Meng H; Linfante I; Yang X
    World Neurosurg; 2017 Jan; 97():344-350. PubMed ID: 27742509
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.