These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

210 related articles for article (PubMed ID: 23524694)

  • 1. Digital design and individually fabricated titanium implants for the reconstruction of traumatic zygomatico-orbital defects.
    Li J; Li P; Lu H; Shen L; Tian W; Long J; Tang W
    J Craniofac Surg; 2013 Mar; 24(2):363-8. PubMed ID: 23524694
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Individual design and rapid prototyping in reconstruction of orbital wall defects.
    Tang W; Guo L; Long J; Wang H; Lin Y; Liu L; Tian W
    J Oral Maxillofac Surg; 2010 Mar; 68(3):562-70. PubMed ID: 20171476
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Semiautomatic procedure for individual preforming of titanium meshes for orbital fractures.
    Metzger MC; Schön R; Zizelmann C; Weyer N; Gutwald R; Schmelzeisen R
    Plast Reconstr Surg; 2007 Mar; 119(3):969-76. PubMed ID: 17312503
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Application of Computer-Aided Designing and Rapid Prototyping Technologies in Reconstruction of Blowout Fractures of the Orbital Floor.
    Tabaković SZ; Konstantinović VS; Radosavljević R; Movrin D; Hadžistević M; Hatab N
    J Craniofac Surg; 2015 Jul; 26(5):1558-63. PubMed ID: 26125649
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Personalized Reconstruction of Traumatic Orbital Defects Based on Precise Three-Dimensional Orientation and Measurements of the Globe.
    Huang L; Lin L; Wang Z; Shi B; Zhu X; Qiu Y; Huang Y; Yu X; Liao Y
    J Craniofac Surg; 2017 Jan; 28(1):172-179. PubMed ID: 27893559
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Orbital Reconstruction by Patient-Specific Implant Printed in Porous Titanium: A Retrospective Case Series of 12 Patients.
    Bachelet JT; Cordier G; Porcheray M; Bourlet J; Gleizal A; Foletti JM
    J Oral Maxillofac Surg; 2018 Oct; 76(10):2161-2167. PubMed ID: 29738747
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Customized titanium reconstruction of post-traumatic orbital wall defects: a review of 22 cases.
    Mustafa SF; Evans PL; Bocca A; Patton DW; Sugar AW; Baxter PW
    Int J Oral Maxillofac Surg; 2011 Dec; 40(12):1357-62. PubMed ID: 21885249
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the application of computer-aided shape-adapted fabricated titanium mesh for mirroring-reconstructing orbital walls in cases of late post-traumatic enophthalmos.
    Zhang Y; He Y; Zhang ZY; An JG
    J Oral Maxillofac Surg; 2010 Sep; 68(9):2070-5. PubMed ID: 20605306
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reconstruction for diverse fronto-orbital defects with computer-assisted designed and computer-assisted manufactured PEEK implants in one-stage operation: Case reports.
    Yang M; Wu Z; Yu H; Cheng J
    Medicine (Baltimore); 2021 Oct; 100(40):e27452. PubMed ID: 34622866
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Can customized implants correct enophthalmos and delayed diplopia in post-traumatic orbital deformities? A volumetric analysis.
    Pedemonte C; Sáez F; Vargas I; González LE; Canales M; Salazar K
    Int J Oral Maxillofac Surg; 2016 Sep; 45(9):1086-94. PubMed ID: 27157630
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Orbital Reconstruction: Patient-Specific Orbital Floor Reconstruction Using a Mirroring Technique and a Customized Titanium Mesh.
    Tarsitano A; Badiali G; Pizzigallo A; Marchetti C
    J Craniofac Surg; 2016 Oct; 27(7):1822-1825. PubMed ID: 27438454
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Virtual surgery simulation in orbital wall reconstruction: integration of surgical navigation and stereolithographic models.
    Novelli G; Tonellini G; Mazzoleni F; Bozzetti A; Sozzi D
    J Craniomaxillofac Surg; 2014 Dec; 42(8):2025-34. PubMed ID: 25458348
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Treatment with individual orbital wall implants in humans - 1-Year ophthalmologic evaluation.
    Kozakiewicz M; Elgalal M; Piotr L; Broniarczyk-Loba A; Stefanczyk L
    J Craniomaxillofac Surg; 2011 Jan; 39(1):30-6. PubMed ID: 20417112
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development and demonstration of a novel computer planning solution for predefined correction of enophthalmos in anophthalmic patients using prebended 3D titanium-meshes--a technical note.
    Rana M; Essig H; Rücker M; Gellrich NC
    J Oral Maxillofac Surg; 2012 Nov; 70(11):e631-8. PubMed ID: 23078825
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Digital surgical technology in reconstruction of orbital frame].
    He LS; Shang HT; Bai SZ; Bo B
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2011 Aug; 46(8):452-7. PubMed ID: 22169739
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [One-stage reconstruction of zygomatico-orbital complex with the use of implants of different origin].
    Menabde GT; Gvenetadze ZV; Atskvereli LSh
    Georgian Med News; 2009 Mar; (168):23-7. PubMed ID: 19359714
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical application of 3D pre-bent titanium implants for orbital floor fractures.
    Kozakiewicz M; Elgalal M; Loba P; Komuński P; Arkuszewski P; Broniarczyk-Loba A; Stefańczyk L
    J Craniomaxillofac Surg; 2009 Jun; 37(4):229-34. PubMed ID: 19186068
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Orbital reconstruction: prefabricated implants, data transfer, and revision surgery.
    Bittermann G; Metzger MC; Schlager S; Lagrèze WA; Gross N; Cornelius CP; Schmelzeisen R
    Facial Plast Surg; 2014 Oct; 30(5):554-60. PubMed ID: 25397711
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Computer-assisted design and manufacture of implants in the late reconstruction of extensive orbital fractures.
    Lieger O; Richards R; Liu M; Lloyd T
    Arch Facial Plast Surg; 2010; 12(3):186-91. PubMed ID: 20479435
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Customized Titanium Mesh Based on the 3D Printed Model vs. Manual Intraoperative Bending of Titanium Mesh for Reconstructing of Orbital Bone Fracture: A Randomized Clinical Trial.
    Raisian S; Fallahi HR; Khiabani KS; Heidarizadeh M; Azdoo S
    Rev Recent Clin Trials; 2017; 12(3):154-158. PubMed ID: 28828975
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.