These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 23532453)

  • 21. Comparison of Intraocular Pressure Measurements between Icare Pro Rebound Tonometer and Tono-Pen XL Tonometer in Supine and Lateral Decubitus Body Positions.
    Lee TE; Yoo C; Hwang JY; Lin S; Kim YY
    Curr Eye Res; 2015 Sep; 40(9):923-9. PubMed ID: 25271991
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of the Icare ic100 Rebound Tonometer and the Goldmann Applanation Tonometer in 1,000 Eyes.
    Subramaniam AG; Allen P; Toh T
    Ophthalmic Res; 2021; 64(2):321-326. PubMed ID: 32906125
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of a new rebound tonometer for self-measurement of intraocular pressure.
    Dabasia PL; Lawrenson JG; Murdoch IE
    Br J Ophthalmol; 2016 Aug; 100(8):1139-43. PubMed ID: 26614630
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Analysis of reproducibility, evaluation, and preference of the new iC100 rebound tonometer versus iCare PRO and Perkins portable applanation tonometry.
    Molero-Senosiaín M; Morales-Fernández L; Saenz-Francés F; García-Feijoo J; Martínez-de-la-Casa JM
    Eur J Ophthalmol; 2020 Nov; 30(6):1349-1355. PubMed ID: 31565972
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Rebound tonometry measurements over extended-wear bandage contact lenses.
    Azarcon CP; Dela Cruz RC
    Cont Lens Anterior Eye; 2020 Oct; 43(5):503-506. PubMed ID: 32151529
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Rebound Tonometry over Soft Contact Lenses.
    Krolo I; Mihaljevic B; Kasumovic A; Bagatin F; Ravlic MM; Herman JS
    Acta Inform Med; 2020 Sep; 28(3):185-189. PubMed ID: 33417647
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Measurement of the intraocular pressure with the "transpalpebral tonometer" TGDc-01 in comparison with applanation tonometry.
    Sandner D; Böhm A; Kostov S; Pillunat L
    Graefes Arch Clin Exp Ophthalmol; 2005 Jun; 243(6):563-9. PubMed ID: 15614540
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The Icare HOME (TA022) Study: Performance of an Intraocular Pressure Measuring Device for Self-Tonometry by Glaucoma Patients.
    Mudie LI; LaBarre S; Varadaraj V; Karakus S; Onnela J; Munoz B; Friedman DS
    Ophthalmology; 2016 Aug; 123(8):1675-1684. PubMed ID: 27289178
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Intraocular pressure measurement with the noncontact tonometer through soft contact lenses.
    Liu YC; Huang JY; Wang IJ; Hu FR; Hou YC
    J Glaucoma; 2011 Mar; 20(3):179-82. PubMed ID: 19593202
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Icare rebound tonometry in children with known and suspected glaucoma.
    Flemmons MS; Hsiao YC; Dzau J; Asrani S; Jones S; Freedman SF
    J AAPOS; 2011 Apr; 15(2):153-7. PubMed ID: 21419676
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Comparison of measurement of intraocular pressure by ICARE PRO® tonometer and Goldman applanation tonometer].
    Hladíková E; Pluháček F; Marešová K
    Cesk Slov Oftalmol; 2014 Jun; 70(3):90-3. PubMed ID: 25032793
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A comparative study of intraocular pressure measurement by three tonometers in normal subjects.
    Prabhakar SK; Mahesh BS; Shanthamallappa M
    Nepal J Ophthalmol; 2013; 5(2):201-6. PubMed ID: 24172555
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The Influence of Corneal Biomechanical Properties on Intraocular Pressure Measurements Using a Rebound Self-tonometer.
    Brown L; Foulsham W; Pronin S; Tatham AJ
    J Glaucoma; 2018 Jun; 27(6):511-518. PubMed ID: 29557828
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of Body Position on Intraocular Pressure Measured by Rebound Tonometer in Healthy Children.
    Uzlu D; Akyol N; Türk A; Gürsoy N; Somuncu AM; Oruç Y
    Turk J Ophthalmol; 2020 Oct; 50(5):271-274. PubMed ID: 33342193
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Precision and accuracy of the ICare tonometer - Peripheral and central IOP measurements by rebound tonometry.
    Muttuvelu DV; Baggesen K; Ehlers N
    Acta Ophthalmol; 2012 Jun; 90(4):322-6. PubMed ID: 20840218
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Applanation tonometry in silicone hydrogel contact lens wearers.
    Allen RJ; Dev Borman A; Saleh GM
    Cont Lens Anterior Eye; 2007 Dec; 30(5):267-9. PubMed ID: 17382579
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Clinical comparison of the TonoVet(®) rebound tonometer and the Tono-Pen Vet(®) applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathology.
    von Spiessen L; Karck J; Rohn K; Meyer-Lindenberg A
    Vet Ophthalmol; 2015 Jan; 18(1):20-7. PubMed ID: 24131625
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The Icare-Pro Rebound Tonometer Versus the Hand-held Applanation Tonometer in Congenital Glaucoma.
    Borrego Sanz L; Morales-Fernandez L; Martínez de-la-Casa JM; Sáenz-Francés F; Fuentes M; García-Feijóo J
    J Glaucoma; 2016 Feb; 25(2):149-54. PubMed ID: 25333612
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Rebound tonometer: ideal tonometer for measurement of accurate intraocular pressure.
    Suman S; Agrawal A; Pal VK; Pratap VB
    J Glaucoma; 2014 Dec; 23(9):633-7. PubMed ID: 23429611
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Clinical evaluation of the dynamic rebound tonometer Icare].
    Detry-Morel M; Jamart J; Detry MB; Pourjavan S; Charlier L; Dethinne B; Huge L; Ledoux A
    J Fr Ophtalmol; 2006 Dec; 29(10):1119-27. PubMed ID: 17211320
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.