153 related articles for article (PubMed ID: 23540722)
1. Proximal femur bone strength estimated by a computationally fast finite element analysis in a sideways fall configuration.
Nishiyama KK; Gilchrist S; Guy P; Cripton P; Boyd SK
J Biomech; 2013 Apr; 46(7):1231-6. PubMed ID: 23540722
[TBL] [Abstract][Full Text] [Related]
2. Cortical bone finite element models in the estimation of experimentally measured failure loads in the proximal femur.
Koivumäki JE; Thevenot J; Pulkkinen P; Kuhn V; Link TM; Eckstein F; Jämsä T
Bone; 2012 Oct; 51(4):737-40. PubMed ID: 22796418
[TBL] [Abstract][Full Text] [Related]
3. New QCT analysis approach shows the importance of fall orientation on femoral neck strength.
Carpenter RD; Beaupré GS; Lang TF; Orwoll ES; Carter DR;
J Bone Miner Res; 2005 Sep; 20(9):1533-42. PubMed ID: 16059625
[TBL] [Abstract][Full Text] [Related]
4. Microstructural failure mechanisms in the human proximal femur for sideways fall loading.
Nawathe S; Akhlaghpour H; Bouxsein ML; Keaveny TM
J Bone Miner Res; 2014 Feb; 29(2):507-15. PubMed ID: 23832419
[TBL] [Abstract][Full Text] [Related]
5. The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs.
Papini M; Zdero R; Schemitsch EH; Zalzal P
J Biomech Eng; 2007 Feb; 129(1):12-9. PubMed ID: 17227093
[TBL] [Abstract][Full Text] [Related]
6. Ct-based finite element models can be used to estimate experimentally measured failure loads in the proximal femur.
Koivumäki JE; Thevenot J; Pulkkinen P; Kuhn V; Link TM; Eckstein F; Jämsä T
Bone; 2012 Apr; 50(4):824-9. PubMed ID: 22306697
[TBL] [Abstract][Full Text] [Related]
7. Robust QCT/FEA models of proximal femur stiffness and fracture load during a sideways fall on the hip.
Dragomir-Daescu D; Op Den Buijs J; McEligot S; Dai Y; Entwistle RC; Salas C; Melton LJ; Bennet KE; Khosla S; Amin S
Ann Biomed Eng; 2011 Feb; 39(2):742-55. PubMed ID: 21052839
[TBL] [Abstract][Full Text] [Related]
8. Comparison of non-invasive assessments of strength of the proximal femur.
Johannesdottir F; Thrall E; Muller J; Keaveny TM; Kopperdahl DL; Bouxsein ML
Bone; 2017 Dec; 105():93-102. PubMed ID: 28739416
[TBL] [Abstract][Full Text] [Related]
9. A nonlinear QCT-based finite element model validation study for the human femur tested in two configurations in vitro.
Dall'Ara E; Luisier B; Schmidt R; Kainberger F; Zysset P; Pahr D
Bone; 2013 Jan; 52(1):27-38. PubMed ID: 22985891
[TBL] [Abstract][Full Text] [Related]
10. Study of stress variations in single-stance and sideways fall using image-based finite element analysis.
Faisal TR; Luo Y
Biomed Mater Eng; 2016 May; 27(1):1-14. PubMed ID: 27175463
[TBL] [Abstract][Full Text] [Related]
11. [Finite Element Analysis (FEA) for the structure capacity of proximal femur during falling--(II). The effects of falling configuration and load locations on the structural capacity of the proximal femur].
Fan L; Wang E
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Dec; 23(6):1245-9. PubMed ID: 17228718
[TBL] [Abstract][Full Text] [Related]
12. Simulation of hip fracture in sideways fall using a 3D finite element model of pelvis-femur-soft tissue complex with simplified representation of whole body.
Majumder S; Roychowdhury A; Pal S
Med Eng Phys; 2007 Dec; 29(10):1167-78. PubMed ID: 17270483
[TBL] [Abstract][Full Text] [Related]
13. Orthotropic HR-pQCT-based FE models improve strength predictions for stance but not for side-way fall loading compared to isotropic QCT-based FE models of human femurs.
Luisier B; Dall'Ara E; Pahr DH
J Mech Behav Biomed Mater; 2014 Apr; 32():287-299. PubMed ID: 24508715
[TBL] [Abstract][Full Text] [Related]
14. Can CT image deblurring improve finite element predictions at the proximal femur?
Falcinelli C; Schileo E; Pakdel A; Whyne C; Cristofolini L; Taddei F
J Mech Behav Biomed Mater; 2016 Oct; 63():337-351. PubMed ID: 27450036
[TBL] [Abstract][Full Text] [Related]
15. Mapping anisotropy of the proximal femur for enhanced image based finite element analysis.
Enns-Bray WS; Owoc JS; Nishiyama KK; Boyd SK
J Biomech; 2014 Oct; 47(13):3272-8. PubMed ID: 25219361
[TBL] [Abstract][Full Text] [Related]
16. Morphology based anisotropic finite element models of the proximal femur validated with experimental data.
Enns-Bray WS; Ariza O; Gilchrist S; Widmer Soyka RP; Vogt PJ; Palsson H; Boyd SK; Guy P; Cripton PA; Ferguson SJ; Helgason B
Med Eng Phys; 2016 Nov; 38(11):1339-1347. PubMed ID: 27641660
[TBL] [Abstract][Full Text] [Related]
17. Mapping anisotropy improves QCT-based finite element estimation of hip strength in pooled stance and side-fall load configurations.
Panyasantisuk J; Dall'Ara E; Pretterklieber M; Pahr DH; Zysset PK
Med Eng Phys; 2018 Sep; 59():36-42. PubMed ID: 30131112
[TBL] [Abstract][Full Text] [Related]
18. A novel approach to estimate trabecular bone anisotropy using a database approach.
Hazrati Marangalou J; Ito K; Cataldi M; Taddei F; van Rietbergen B
J Biomech; 2013 Sep; 46(14):2356-62. PubMed ID: 23972430
[TBL] [Abstract][Full Text] [Related]
19. Prediction of fracture load and stiffness of the proximal femur by CT-based specimen specific finite element analysis: cadaveric validation study.
Miura M; Nakamura J; Matsuura Y; Wako Y; Suzuki T; Hagiwara S; Orita S; Inage K; Kawarai Y; Sugano M; Nawata K; Ohtori S
BMC Musculoskelet Disord; 2017 Dec; 18(1):536. PubMed ID: 29246133
[TBL] [Abstract][Full Text] [Related]
20. Novel approach of predicting fracture load in the human proximal femur using non-invasive QCT imaging technique.
Lee T; Pereira BP; Chung YS; Oh HJ; Choi JB; Lim D; Shin JH
Ann Biomed Eng; 2009 May; 37(5):966-75. PubMed ID: 19288197
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]