These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 23540722)

  • 21. To what extent can linear finite element models of human femora predict failure under stance and fall loading configurations?
    Schileo E; Balistreri L; Grassi L; Cristofolini L; Taddei F
    J Biomech; 2014 Nov; 47(14):3531-8. PubMed ID: 25261321
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Exercise loading history and femoral neck strength in a sideways fall: A three-dimensional finite element modeling study.
    Abe S; Narra N; Nikander R; Hyttinen J; Kouhia R; Sievänen H
    Bone; 2016 Nov; 92():9-17. PubMed ID: 27477004
    [TBL] [Abstract][Full Text] [Related]  

  • 23. During sideways falls proximal femur fractures initiate in the superolateral cortex: evidence from high-speed video of simulated fractures.
    de Bakker PM; Manske SL; Ebacher V; Oxland TR; Cripton PA; Guy P
    J Biomech; 2009 Aug; 42(12):1917-25. PubMed ID: 19524929
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Femoral structure and stiffness in patients with femoral neck fracture.
    Cody DD; Hou FJ; Divine GW; Fyhrie DP
    J Orthop Res; 2000 May; 18(3):443-8. PubMed ID: 10937632
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Quantitative computed tomography-based finite element analysis predictions of femoral strength and stiffness depend on computed tomography settings.
    Dragomir-Daescu D; Salas C; Uthamaraj S; Rossman T
    J Biomech; 2015 Jan; 48(1):153-61. PubMed ID: 25442008
    [TBL] [Abstract][Full Text] [Related]  

  • 26. In Vivo Assessment of Age- and Loading Configuration-Related Changes in Multiscale Mechanical Behavior of the Human Proximal Femur Using MRI-Based Finite Element Analysis.
    Zhang L; Wang L; Fu R; Wang J; Yang D; Liu Y; Zhang W; Liang W; Yang R; Yang H; Cheng X
    J Magn Reson Imaging; 2021 Mar; 53(3):905-912. PubMed ID: 33075178
    [TBL] [Abstract][Full Text] [Related]  

  • 27. In situ parameter identification of optimal density-elastic modulus relationships in subject-specific finite element models of the proximal femur.
    Cong A; Buijs JO; Dragomir-Daescu D
    Med Eng Phys; 2011 Mar; 33(2):164-73. PubMed ID: 21030287
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Reliable simulations of the human proximal femur by high-order finite element analysis validated by experimental observations.
    Yosibash Z; Trabelsi N; Milgrom C
    J Biomech; 2007; 40(16):3688-99. PubMed ID: 17706228
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A robust 3D finite element simulation of human proximal femur progressive fracture under stance load with experimental validation.
    Hambli R; Allaoui S
    Ann Biomed Eng; 2013 Dec; 41(12):2515-27. PubMed ID: 23864338
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Validation of subject-specific automated p-FE analysis of the proximal femur.
    Trabelsi N; Yosibash Z; Milgrom C
    J Biomech; 2009 Feb; 42(3):234-41. PubMed ID: 19118831
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Age trends in femur stresses from a simulated fall on the hip among men and women: evidence of homeostatic adaptation underlying the decline in hip BMD.
    Beck TJ; Looker AC; Mourtada F; Daphtary MM; Ruff CB
    J Bone Miner Res; 2006 Sep; 21(9):1425-32. PubMed ID: 16939401
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Femoral strength is better predicted by finite element models than QCT and DXA.
    Cody DD; Gross GJ; Hou FJ; Spencer HJ; Goldstein SA; Fyhrie DP
    J Biomech; 1999 Oct; 32(10):1013-20. PubMed ID: 10476839
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Impact loading history modulates hip fracture load and location: A finite element simulation study of the proximal femur in female athletes.
    Abe S; Narra N; Nikander R; Hyttinen J; Kouhia R; Sievänen H
    J Biomech; 2018 Jul; 76():136-143. PubMed ID: 29921524
    [TBL] [Abstract][Full Text] [Related]  

  • 34. QCT-based failure analysis of proximal femurs under various loading orientations.
    Mirzaei M; Keshavarzian M; Alavi F; Amiri P; Samiezadeh S
    Med Biol Eng Comput; 2015 Jun; 53(6):477-86. PubMed ID: 25731689
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A comparative study between axial compression and lateral fall configuration tested in a rat proximal femur model.
    Zhang G; Qin L; Shi Y; Leung K
    Clin Biomech (Bristol, Avon); 2005 Aug; 20(7):729-35. PubMed ID: 15963616
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Contribution of trochanteric soft tissues to fall force estimates, the factor of risk, and prediction of hip fracture risk.
    Bouxsein ML; Szulc P; Munoz F; Thrall E; Sornay-Rendu E; Delmas PD
    J Bone Miner Res; 2007 Jun; 22(6):825-31. PubMed ID: 17352651
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Influence of bone lesion location on femoral bone strength assessed by MRI-based finite-element modeling.
    Rajapakse CS; Gupta N; Evans M; Alizai H; Shukurova M; Hong AL; Cruickshank NJ; Tejwani N; Egol K; Honig S; Chang G
    Bone; 2019 May; 122():209-217. PubMed ID: 30851438
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The predictive ability of a QCT-FE model of the proximal femoral stiffness under multiple load cases is strongly influenced by experimental uncertainties.
    Amini M; Reisinger A; Synek A; Hirtler L; Pahr D
    J Mech Behav Biomed Mater; 2023 Mar; 139():105664. PubMed ID: 36657193
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Three-dimensional micro-level computational study of Wolff's law via trabecular bone remodeling in the human proximal femur using design space topology optimization.
    Boyle C; Kim IY
    J Biomech; 2011 Mar; 44(5):935-42. PubMed ID: 21159341
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Analysis of strength and failure pattern of human proximal femur using quantitative computed tomography (QCT)-based finite element method.
    Mirzaei M; Keshavarzian M; Naeini V
    Bone; 2014 Jul; 64():108-14. PubMed ID: 24735974
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.