These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

49 related articles for article (PubMed ID: 23545278)

  • 1. Utility of neut-X, neut-Y and neut-Z parameters for rapidly assessing sepsis in tumor patients.
    Luo Y; Lin J; Chen H; Zhang J; Peng S; Kuang M
    Clin Chim Acta; 2013 Jun; 422():5-9. PubMed ID: 23545278
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The utility of the Sysmex XE-2100 analyzer's NEUT-X and NEUT-Y parameters for detecting neutrophil dysplasia in myelodysplastic syndromes.
    Furundarena JR; Araiz M; Uranga M; Sainz MR; Agirre A; Trassorras M; Uresandi N; Montes MC; Argoitia N
    Int J Lab Hematol; 2010 Jun; 32(3):360-6. PubMed ID: 19906272
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Value of percentage of highly fluorescent lymphocytic cells for rapidly assessing septicemia in tumor patients].
    Luo YL; Xu PG; Peng SG; Li JP; Kuang MH
    Zhonghua Yi Xue Za Zhi; 2013 Jun; 93(24):1894-6. PubMed ID: 24124742
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The Utility of XE-2 100 Analyzer's NEUT-X and NEUT-Y Parameters for Detecting Neutrophil Dysplasia in Myelodysplastic Syndromes].
    Isono S; Okamur A; Iwamoto M; ImaiJunko IMAI ; Nagata K; Akishino T; Okamura A; Kawamoto S; Kono M; Sugimoto T; Saigo K
    Rinsho Byori; 2016 Jan; 64(1):21-6. PubMed ID: 27192792
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detection and quantification of hypo- and hypergranulated neutrophils on the new Sysmex XN hematology analyzer: establishment of an adapted reference interval for the neutrophil-granularity-intensity compared to XE-technology in adult patients.
    Zimmermann M; Steenhuis P; Linssen J; Weimann A
    Clin Lab; 2015; 61(3-4):235-41. PubMed ID: 25974988
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of neutrophil CD64 expression, manual myeloid immaturity counts, and automated hematology analyzer flags as indicators of infection or sepsis.
    Davis BH; Bigelow NC
    Lab Hematol; 2005; 11(2):137-47. PubMed ID: 16024338
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Granularity Index of the SYSMEX XE-5000 hematology analyzer as a replacement for manual microscopy of toxic granulation neutrophils in patients with inflammatory diseases.
    Zimmermann M; Cremer M; Hoffmann C; Weimann K; Weimann A
    Clin Chem Lab Med; 2011 Jul; 49(7):1193-8. PubMed ID: 21574880
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mean cell volume of neutrophils and monocytes compared with C-reactive protein, interleukin-6 and white blood cell count for prediction of sepsis and nonsystemic bacterial infections.
    Mardi D; Fwity B; Lobmann R; Ambrosch A
    Int J Lab Hematol; 2010 Aug; 32(4):410-8. PubMed ID: 19919621
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Neutrophil volume, conductivity and scatter parameters with effective modeling of molecular activity statistical program gives better results in neonatal sepsis.
    Celik IH; Demirel G; Sukhachev D; Erdeve O; Dilmen U
    Int J Lab Hematol; 2013 Feb; 35(1):82-7. PubMed ID: 22938598
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Secondary Retrospective Analysis of the Predictive Value of Neutrophil-Reactive Intensity (NEUT-RI) in Septic and Non-Septic Patients in Intensive Care.
    Formenti P; Isidori L; Pastori S; Roccaforte V; Mantovani EA; Iezzi M; Menozzi A; Panella R; Galimberti A; Brenna G; Umbrello M; Pezzi A; Vetrone F; Sabbatini G; Gotti M
    Diagnostics (Basel); 2024 Apr; 14(8):. PubMed ID: 38667467
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The diagnostic and prognostic values of serum total RNA concentration in patients with sepsis].
    Wang HJ; Xie LX
    Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2012 May; 24(5):269-73. PubMed ID: 22587920
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Usefulness of C-reactive protein for the diagnosis of neonatal sepsis].
    Baptista-González HA; Ibarra-Camacho A; Cedillo RE; Torres-Alipi BI
    Bol Med Hosp Infant Mex; 1989 Aug; 46(8):543-6. PubMed ID: 2803537
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Potential Role of Neutrophil-Reactive Intensity (NEUT-RI) in the Diagnosis of Sepsis in Critically Ill Patients: A Retrospective Cohort Study.
    Mantovani EMA; Formenti P; Pastori S; Roccaforte V; Gotti M; Panella R; Galimberti A; Costagliola R; Vetrone F; Umbrello M; Pezzi A; Sabbatini G
    Diagnostics (Basel); 2023 May; 13(10):. PubMed ID: 37238265
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluating the QuikRead® C-reactive protein test as a point-of-care test.
    Diar HA; Nakwa FL; Thomas R; Libhaber EN; Velaphi S
    Paediatr Int Child Health; 2012 Feb; 32(1):35-42. PubMed ID: 22525446
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Predictive values of serial C-reactive protein in neonatal sepsis.
    Nuntnarumit P; Pinkaew O; Kitiwanwanich S
    J Med Assoc Thai; 2002 Nov; 85 Suppl 4():S1151-8. PubMed ID: 12549789
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Diagnostic value of C- reactive protein and haematological parameters in neonatal sepsis.
    Ahmed Z; Ghafoor T; Waqar T; Ali S; Aziz S; Mahmud S
    J Coll Physicians Surg Pak; 2005 Mar; 15(3):152-6. PubMed ID: 15808093
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diagnostic and Prognostic Values of Neutrophil Reactivity Intensity (NEUT-RI) in Pediatric Systemic Inflammatory Response Syndrome and Sepsis.
    Lee J; Gu J; Seo JE; Kim JW; Kim HK
    Ann Clin Lab Sci; 2023 Mar; 53(2):173-180. PubMed ID: 37094848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Changes in novel haematological parameters following thermal injury: A prospective observational cohort study.
    Dinsdale RJ; Devi A; Hampson P; Wearn CM; Bamford AL; Hazeldine J; Bishop J; Ahmed S; Watson C; Lord JM; Moiemen N; Harrison P
    Sci Rep; 2017 Jun; 7(1):3211. PubMed ID: 28607467
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The clinical value of hematological neutrophil and monocyte parameters in the diagnosis and identification of sepsis.
    Zhang W; Zhang Z; Pan S; Li J; Yang Y; Qi H; Xie J; Qu J
    Ann Transl Med; 2021 Nov; 9(22):1680. PubMed ID: 34988189
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Neutrophil side fluorescence: a new indicator for predicting the severity of patients with bronchiectasis.
    Li S; Yu C; Jie H; Han X; Zou S; Tan Q; Luo S; Chen Y; Wang J
    BMC Pulm Med; 2022 Mar; 22(1):107. PubMed ID: 35346147
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.