These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

201 related articles for article (PubMed ID: 23549548)

  • 21. Experimental verification of stress compensation in the SBTC-cut.
    Valdois M; Sinha BK; Boy JJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 1989; 36(6):643-51. PubMed ID: 18290245
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An analysis of the thickness vibration of an unelectroded doubly-rotated quartz circular plate.
    Xie L; Wang S; Zhang C; Wang J
    J Acoust Soc Am; 2018 Aug; 144(2):814. PubMed ID: 30180667
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Energy trapping in high-frequency vibrations of piezoelectric plates with partial mass layers under lateral electric field excitation.
    Liu B; Jiang Q; Xie H; Yang J
    Ultrasonics; 2011 Apr; 51(3):376-81. PubMed ID: 21145572
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Experimental study on the characteristic of the NS-GT cut quartz crystal resonator oscillating in the sub-resonant frequency.
    Yamagata S; Kawashima H
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(5):1175-82. PubMed ID: 18244311
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The calculation of electrical parameters of AT-cut quartz crystal resonators with the consideration of material viscosity.
    Wang J; Zhao W; Du J; Hu Y
    Ultrasonics; 2011 Jan; 51(1):65-70. PubMed ID: 20594568
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Mass-frequency influence surface, mode shapes, and frequency spectrum of a rectangular AT-cut quartz plate.
    Yong YK; Stewart JT
    IEEE Trans Ultrason Ferroelectr Freq Control; 1991; 38(1):67-73. PubMed ID: 18267559
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Theory and experimental verifications of the resonator Q and equivalent electrical parameters due to viscoelastic and mounting supports losses.
    Yong YK; Patel MS; Tanaka M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Aug; 57(8):1831-9. PubMed ID: 20679012
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A Semi-Analytical Solution for the Thickness-Vibration of Centrally Partially-Electroded Circular AT-Cut Quartz Resonators.
    Wang B; Dai X; Zhao X; Qian Z
    Sensors (Basel); 2017 Aug; 17(8):. PubMed ID: 28783124
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Thickness-twist and face-shear waves in piezoelectric plates of monoclinic crystals.
    Zhu J; Chen W
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Dec; 58(12):2763-7. PubMed ID: 23443714
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effects of a liquid layer on thickness-shear vibrations of rectangular AT-cut quartz plates.
    Lee PC; Huang R
    IEEE Trans Ultrason Ferroelectr Freq Control; 2002 May; 49(5):604-11. PubMed ID: 12046936
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Mechanical effects of electrodes on the vibrations of quartz crystal plates.
    Lee PC; Huang R
    IEEE Trans Ultrason Ferroelectr Freq Control; 2002 May; 49(5):612-25. PubMed ID: 12046937
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Analysis of coupled fast-shear and extensional vibrations of a LiTaO3 crystal plate with a ferroelectric inversion layer.
    Ma T; Pei J; Wang J; Du J; Zhang C; Huang B; Yuan L; Yu F
    J Acoust Soc Am; 2016 May; 139(5):2635. PubMed ID: 27250157
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Nonlinear coupling between thickness- shear and thickness-stretch modes in a rotated Y-cut quartz resonator.
    Yang Z; Hu Y; Wang J; Yang J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Jan; 56(1):220-4. PubMed ID: 19213649
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The determination of the optimal length of crystal blanks in quartz crystal resonators.
    Wang J; Zhao W
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Nov; 52(11):2023-30. PubMed ID: 16422414
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Anharmonic character of the polarizing effect with the thickness modes of alpha-quartz plates.
    Hruska CK; Kucera M
    IEEE Trans Ultrason Ferroelectr Freq Control; 1988; 35(6):842-4. PubMed ID: 18290222
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Laser ultrasonic analysis of normal modes generated by a voltage pulse on an AT quartz sensor.
    Goossens J; Martinez L; Glorieux C; Wilkie-Chancellier N; Ehssein CO; Serfaty S
    Ultrasonics; 2006 Dec; 44 Suppl 1():e1179-82. PubMed ID: 16797645
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of mismatched electrodes on an AT-cut quartz resonator.
    He H; Liu J; Yang J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Feb; 59(2):281-6. PubMed ID: 24626036
    [TBL] [Abstract][Full Text] [Related]  

  • 38. An estimate of the second-order in-plane acceleration sensitivity of a Y-cut quartz thickness-shear resonator.
    He H; Yang J; Kosinski JA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Aug; 62(8):1421-8. PubMed ID: 26276952
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effects of unequal electrode pairs on an x-strip thickness-shear mode multi-channel quartz crystal microbalance.
    Zhao Z; Qian Z; Wang B
    Ultrasonics; 2016 Dec; 72():73-9. PubMed ID: 27484997
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Thickness-shear modes of an elliptical, contoured AT-cut quartz resonator.
    Wang W; Wu R; Wang J; Du J; Yang J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Jun; 60(6):1192-8. PubMed ID: 25004481
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.